The effects of residual hearing in traditional cochlear implant candidates after implantation with a conventional electrode.

Maura K Cosetti1, David R Friedmann, Bovey Z Zhu, Selena E Heman-Ackah, Yixin Fang, Robert G Keller, William H Shapiro, J Thomas Roland, Susan B Waltzman.   

Abstract

OBJECTIVE: To analyze the effects of residual hearing on postoperative speech performance in traditional cochlear implant (CI) patients implanted with a conventional electrode. STUDY
DESIGN: Retrospective review.
SETTING: Academic tertiary referral center. PATIENTS: A total of 129 adults implanted by a single surgeon at a tertiary care facility between June 2005 and November 2010 with measurable preoperative pure tone thresholds at any frequency were included. INTERVENTION: Cochlear implantation with a conventional electrode via an anterior inferior cochleostomy. MAIN OUTCOME MEASURE: Speech perception using monosyllabic word scores in quiet and sentences in quiet and noise in the electric (CI-only) condition of the implanted ear. Preservation of hearing was defined as complete for postoperative thresholds within 10 dB of preimplant values and partial if greater than 11 dB. Pure tone audiometry and speech perception testing were performed preoperatively and at regular intervals postoperatively, with the 1-year evaluation being the final outcome period.
RESULTS: Preservation at any frequency or level was not a factor in speech perception outcome, although preservation was more common in low frequencies. Hearing preservation was correlated with younger age at implantation, but was not related to length of hearing loss, cause of deafness, device type, sex, preoperative speech performance, or low-frequency pure-tone average.
CONCLUSION: Hearing can be preserved in traditional CI patients implanted with a conventional electrode. Although preservation of hearing may have implications for future technology, it is not currently correlated with speech performance in the CI-only condition.

Entities:  

Mesh:

Year:  2013        PMID: 23449440     DOI: 10.1097/MAO.0b013e3182785210

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  9 in total

1.  Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion.

Authors:  Alex D Sweeney; Jacob B Hunter; Matthew L Carlson; Alejandro Rivas; Marc L Bennett; Rene H Gifford; Jack H Noble; David S Haynes; Robert F Labadie; George B Wanna
Journal:  Otolaryngol Head Neck Surg       Date:  2016-02-23       Impact factor: 3.497

2.  Predictive factors for short- and long-term hearing preservation in cochlear implantation with conventional-length electrodes.

Authors:  George B Wanna; Brendan P O'Connell; David O Francis; Rene H Gifford; Jacob B Hunter; Jourdan T Holder; Marc L Bennett; Alejandro Rivas; Robert F Labadie; David S Haynes
Journal:  Laryngoscope       Date:  2017-06-22       Impact factor: 3.325

3.  Intracochlear pressure changes due to round window opening: a model experiment.

Authors:  P Mittmann; A Ernst; I Todt
Journal:  ScientificWorldJournal       Date:  2014-05-22

4.  Intra- and Postoperative Electrocochleography May Be Predictive of Final Electrode Position and Postoperative Hearing Preservation.

Authors:  Brendan P O'Connell; Jourdan T Holder; Robert T Dwyer; René H Gifford; Jack H Noble; Marc L Bennett; Alejandro Rivas; George B Wanna; David S Haynes; Robert F Labadie
Journal:  Front Neurosci       Date:  2017-05-29       Impact factor: 4.677

5.  Intracochlear Pressure Changes After Cochlea Implant Electrode Pullback-Reduction of Intracochlear Trauma.

Authors:  Gina Lauer; Julica Uçta; Lars Decker; Arneborg Ernst; Philipp Mittmann
Journal:  Laryngoscope Investig Otolaryngol       Date:  2019-07-11

6.  Correlation between Speech Perception Outcomes after Cochlear Implantation and Postoperative Acoustic and Electric Hearing Thresholds.

Authors:  Ursina Rüegg; Adrian Dalbert; Dorothe Veraguth; Christof Röösli; Alexander Huber; Flurin Pfiffner
Journal:  J Clin Med       Date:  2021-01-17       Impact factor: 4.241

7.  Robot-Assisted Electrode Array Insertion Becomes Available in Pediatric Cochlear Implant Recipients: First Report and an Intra-Individual Study.

Authors:  Huan Jia; Jinxi Pan; Wenxi Gu; Haoyue Tan; Ying Chen; Zhihua Zhang; Mengda Jiang; Yun Li; Olivier Sterkers; Hao Wu
Journal:  Front Surg       Date:  2021-07-07

Review 8.  Electrode selection for hearing preservation in cochlear implantation: A review of the evidence.

Authors:  Jason A Brant; Michael J Ruckenstein
Journal:  World J Otorhinolaryngol Head Neck Surg       Date:  2016-11-24

9.  Preservation of residual hearing after cochlear implant surgery: an exploration of residual hearing function in a group of recipients at cochlear implant units.

Authors:  Katherine Gautschi-Mills; Katijah Khoza-Shangase; Dhanashree Pillay
Journal:  Braz J Otorhinolaryngol       Date:  2018-03-24
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.