Literature DB >> 23447055

In vivo investigation of restricted diffusion in the human brain with optimized oscillating diffusion gradient encoding.

Anh T Van1, Samantha J Holdsworth, Roland Bammer.   

Abstract

PURPOSE: Previous studies in phantoms and animals using animal MR systems have shown promising results in using oscillating gradient spin echo (OGSE) diffusion acquisition to depict microstructure information. The OGSE approach has also been shown to be a sensitive biomarker of tumor treatment response and white matter-related diseases. Translating these studies to a human MR scanner faces multiple challenges due to the much weaker gradient system. The goals of this study are to optimize the OGSE acquisition for a human MR system and investigate its applicability in the in vivo human brain.
METHODS: An analytical analysis of the OGSE modulation spectrum was provided. Based on this analysis and thorough simulation experiments, the OGSE acquisition was optimized in terms of diffusion waveform shape, waveform timing, and sequence timing-to achieve higher diffusion sensitivity and better sampling of the diffusion spectrum.
RESULTS: The trapezoid-cosine waveform was found to be the optimal OGSE waveform. At the three employed peak encoding frequencies of 18 Hz, 44 Hz, and 63 Hz, the waveform polarity for the least blurry sampling of the diffusion spectrum was 90+/180-, 90+/180+, and 90+/180+, respectively. For the highest diffusion-to-noise ratio at 63 Hz, the b-value was 200 s/mm(2) and the echo time was 116 ms. Using the optimized sequence, a frequency dependence of the measured apparent diffusion coefficients was observed in white matter-dominant regions such as the corpus callosum.
CONCLUSION: The obtained results demonstrate, for the first time, the potential of using an OGSE acquisition for investigating microstructure information on a human MR system.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  3 T human MR; diffusion-to-noise ratio; gradient encoding spectrum; oscillating gradient; oscillating gradient spin echo; restricted diffusion

Mesh:

Year:  2013        PMID: 23447055      PMCID: PMC3732532          DOI: 10.1002/mrm.24632

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain.

Authors:  Mark D Does; Edward C Parsons; John C Gore
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

3.  Modified oscillating gradient pulses for direct sampling of the diffusion spectrum suitable for imaging sequences.

Authors:  Edward C Parsons; Mark D Does; John C Gore
Journal:  Magn Reson Imaging       Date:  2003 Apr-May       Impact factor: 2.546

4.  Tailored utilization of acquired k-space points for GRAPPA reconstruction.

Authors:  Peng Qu; Gary X Shen; Chunsheng Wang; Bing Wu; Jing Yuan
Journal:  J Magn Reson       Date:  2005-05       Impact factor: 2.229

5.  Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Authors:  Stefan Skare; Rexford D Newbould; David B Clayton; Gregory W Albers; Scott Nagle; Roland Bammer
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

6.  The effect of impermeable boundaries of arbitrary geometry on the apparent diffusion coefficient.

Authors:  Astrid F Frøhlich; Sune N Jespersen; Leif Ostergaard; Valerij G Kiselev
Journal:  J Magn Reson       Date:  2008-06-24       Impact factor: 2.229

7.  Surface-to-volume ratio with oscillating gradients.

Authors:  Dmitry S Novikov; Valerij G Kiselev
Journal:  J Magn Reson       Date:  2011-02-16       Impact factor: 2.229

8.  Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain.

Authors:  D Xing; N G Papadakis; C L Huang; V M Lee; T A Carpenter; L D Hall
Journal:  Magn Reson Imaging       Date:  1997       Impact factor: 2.546

9.  Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.

Authors:  D Le Bihan; E Breton; D Lallemand; M L Aubin; J Vignaud; M Laval-Jeantet
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

10.  Real-time optical motion correction for diffusion tensor imaging.

Authors:  Murat Aksoy; Christoph Forman; Matus Straka; Stefan Skare; Samantha Holdsworth; Joachim Hornegger; Roland Bammer
Journal:  Magn Reson Med       Date:  2011-03-22       Impact factor: 4.668

View more
  38 in total

1.  Magnetic resonance imaging of mean cell size in human breast tumors.

Authors:  Junzhong Xu; Xiaoyu Jiang; Hua Li; Lori R Arlinghaus; Eliot T McKinley; Sean P Devan; Benjamin M Hardy; Jingping Xie; Hakmook Kang; A Bapsi Chakravarthy; John C Gore
Journal:  Magn Reson Med       Date:  2019-11-25       Impact factor: 4.668

2.  Mesoscopic structure of neuronal tracts from time-dependent diffusion.

Authors:  Lauren M Burcaw; Els Fieremans; Dmitry S Novikov
Journal:  Neuroimage       Date:  2015-03-30       Impact factor: 6.556

3.  Imaging neurodegeneration in the mouse hippocampus after neonatal hypoxia-ischemia using oscillating gradient diffusion MRI.

Authors:  Manisha Aggarwal; Jennifer Burnsed; Lee J Martin; Frances J Northington; Jiangyang Zhang
Journal:  Magn Reson Med       Date:  2013-10-04       Impact factor: 4.668

4.  Quantification of cell size using temporal diffusion spectroscopy.

Authors:  Xiaoyu Jiang; Hua Li; Jingping Xie; Ping Zhao; John C Gore; Junzhong Xu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

Review 5.  Modeling white matter microstructure.

Authors:  T Duval; N Stikov; J Cohen-Adad
Journal:  Funct Neurol       Date:  2016 Oct/Dec

6.  Diffusion-time dependence of diffusional kurtosis in the mouse brain.

Authors:  Manisha Aggarwal; Matthew D Smith; Peter A Calabresi
Journal:  Magn Reson Med       Date:  2020-02-05       Impact factor: 4.668

7.  The Effect of Microcirculatory Flow on Oscillating Gradient Diffusion MRI and Diffusion Encoding with Dual-Frequency Orthogonal Gradients (DEFOG).

Authors:  Dan Wu; Jiangyang Zhang
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

8.  Assessing the accuracy of using oscillating gradient spin echo sequences with AxCaliber to infer micron-sized axon diameters.

Authors:  Morgan Mercredi; Trevor J Vincent; Christopher P Bidinosti; Melanie Martin
Journal:  MAGMA       Date:  2016-07-13       Impact factor: 2.310

9.  Fast and robust measurement of microstructural dimensions using temporal diffusion spectroscopy.

Authors:  Hua Li; John C Gore; Junzhong Xu
Journal:  J Magn Reson       Date:  2014-02-19       Impact factor: 2.229

10.  Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

Authors:  Hua Li; Xiaoyu Jiang; Jingping Xie; John C Gore; Junzhong Xu
Journal:  Magn Reson Med       Date:  2016-06-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.