Literature DB >> 23445438

All-integrated and highly sensitive paper based device with sample treatment platform for Cd2+ immunodetection in drinking/tap waters.

Adaris M López Marzo1, Josefina Pons, Diane A Blake, Arben Merkoçi.   

Abstract

Nowadays, the development of systems, devices, or methods that integrate several process steps into one multifunctional step for clinical, environmental, or industrial purposes constitutes a challenge for many ongoing research projects. Here, we present a new integrated paper based cadmium (Cd(2+)) immunosensing system in lateral flow format, which integrates the sample treatment process with the analyte detection process. The principle of Cd(2+) detection is based on competitive reaction between the cadmium-ethylenediaminetetraacetic acid-bovine serum albumin-gold nanoparticles (Cd-EDTA-BSA-AuNP) conjugate deposited on the conjugation pad strip and the Cd-EDTA complex formed in the analysis sample for the same binding sites of the 2A81G5 monoclonal antibody (mAb), specific to Cd-EDTA but not Cd(2+) free, which is immobilized onto the test line. This platform operates without any sample pretreatment step for Cd(2+) detection thanks to an extra conjugation pad that ensures Cd(2+) complexation with EDTA and interference masking through ovalbumin (OVA). The detection and quantification limits found for the device were 0.1 and 0.4 ppb, respectively, these being the lowest limits reported up to now for metal sensors based on paper. The accuracy of the device was evaluated by addition of known quantities of Cd(2+) to different drinking water samples and subsequent Cd(2+) content analysis. Sample recoveries ranged from 95 to 105% and the coefficient of variation for the intermediate precision assay was less than 10%. In addition, the results obtained here were compared with those obtained with the well-established inductively coupled plasma emission spectroscopy (ICPES) and the analysis of certificate standard samples.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23445438     DOI: 10.1021/ac3034536

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

Review 1.  A review on advances in methods for modification of paper supports for use in point-of-care testing.

Authors:  Rui Hua Tang; Li Na Liu; Su Feng Zhang; Xiao Cong He; Xiu Jun Li; Feng Xu; Yong Hao Ni; Fei Li
Journal:  Mikrochim Acta       Date:  2019-07-09       Impact factor: 5.833

2.  Colorimetric detection of L-histidine based on the target-triggered self-cleavage of swing-structured DNA duplex-induced aggregation of gold nanoparticles.

Authors:  Yunfei Jiao; Qingyun Liu; Hong Qiang; Zhengbo Chen
Journal:  Mikrochim Acta       Date:  2018-09-12       Impact factor: 5.833

3.  On-site detection of heavy metals in wastewater using a single paper strip integrated with a smartphone.

Authors:  Supattra Muhammad-Aree; Siriwan Teepoo
Journal:  Anal Bioanal Chem       Date:  2020-01-09       Impact factor: 4.142

Review 4.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

5.  Paper-Based Sensor Chip for Heavy Metal Ion Detection by SWSV.

Authors:  Xiaoqing Wang; Jizhou Sun; Jianhua Tong; Xin Guan; Chao Bian; Shanhong Xia
Journal:  Micromachines (Basel)       Date:  2018-03-27       Impact factor: 2.891

6.  Novel Latex Microsphere Immunochromatographic Assay for Rapid Detection of Cadmium Ion in Asparagus.

Authors:  Naifeng Xu; Qiaojuan Zhu; Jiangxiong Zhu; Jingze Jia; Xinlin Wei; Yuanfeng Wang
Journal:  Foods       Date:  2021-12-29

7.  Calling Biomarkers in Milk Using a Protein Microarray on Your Smartphone.

Authors:  Susann K J Ludwig; Christian Tokarski; Stefan N Lang; Leendert A van Ginkel; Hongying Zhu; Aydogan Ozcan; Michel W F Nielen
Journal:  PLoS One       Date:  2015-08-26       Impact factor: 3.240

8.  Rapid detection of transition metals in welding fumes using paper-based analytical devices.

Authors:  David M Cate; Pavisara Nanthasurasak; Pornpak Riwkulkajorn; Christian L'Orange; Charles S Henry; John Volckens
Journal:  Ann Occup Hyg       Date:  2014-02-10

9.  Uranium (VI) detection in groundwater using a gold nanoparticle/paper-based lateral flow device.

Authors:  Daniel Quesada-González; Grace A Jairo; Robert C Blake; Diane A Blake; Arben Merkoçi
Journal:  Sci Rep       Date:  2018-11-01       Impact factor: 4.379

10.  Integrating high-performing electrochemical transducers in lateral flow assay.

Authors:  Antonia Perju; Nongnoot Wongkaew
Journal:  Anal Bioanal Chem       Date:  2021-04-28       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.