Detection of placenta elasticity modulus by quantitative real-time shear wave imaging.

W J Li1, Z T Wei, R L Yan, Y L Zhang.   

Abstract

OBJECTIVE: To explore the clinical values in detecting the placental elastic modulus using real-time quantitative shear wave elasticity imaging.
METHODS: A total of 30 women in the late pregnancy stage without complications and having normal, single pregnancies, as well as normal fetal growth, amniotic fluid index, and anterior placenta were selected. A real-time elasticity imaging shear wave ultrasonic diagnostic apparatus was used to randomly select regions of interest at the central and edge of the placenta. The elastography imaging mode was launched to measure the elasticity of the elastic modulus of these placental parts. A total of 15 measured values were obtained at the placental center and edge for each pregnancy case. Umbilical artery and uterine artery pulsatility index (PI) values for 18 cases were also randomly measured.
RESULTS: The average value of 30 placental edges of the elastic modulus (n = 15) was (7.60 +/- 1.71) kPa. The average value of the 30 placental central elastic modulus (n = 15 ) was (7.84 +/- 1.68) kPa. No significant difference was observed between placenta central and edge elastic modulus. The PI mean value of umbilical artery in 18 cases was 0.94, whereas the average PI values of the uterine artery was 0.83. No linear correlation was found among the elastic modulus, the placental uterine artery PI values, and the umbilical artery PI values (p > 0.05).
CONCLUSION: No difference between the placental center of normal pregnancies and the edge of the elastic modulus was detected. The elastic modulus of the placenta could be obtained in the best position. The placenta varied greatly between elastic modulus. No correlation was found between the placental elastic modulus, the uterine artery, and umbilical artery PI values. Real-time shear wave elasticity imaging technology can provide morphological evidence of placental function, which may emerge as a new clinical assessment approach.

Entities:  

Mesh:

Year:  2012        PMID: 23444746

Source DB:  PubMed          Journal:  Clin Exp Obstet Gynecol        ISSN: 0390-6663            Impact factor:   0.146


  9 in total

1.  Effect of depth on shear-wave elastography estimated in the internal and external cervical os during pregnancy.

Authors:  Edgar Hernandez-Andrade; Alma Aurioles-Garibay; Maynor Garcia; Steven J Korzeniewski; Alyse G Schwartz; Hyunyoung Ahn; Alicia Martinez-Varea; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2014-09       Impact factor: 1.901

2.  Shear wave elastography of placenta: in vivo quantitation of placental elasticity in preeclampsia.

Authors:  Fahrettin Kılıç; Yasemin Kayadibi; Mehmet Aytaç Yüksel; İbrahim Adaletli; Fethi Emre Ustabaşıoğlu; Mahmut Öncül; Rıza Madazlı; Mehmet Halit Yılmaz; İsmail Mihmanlı; Fatih Kantarcı
Journal:  Diagn Interv Radiol       Date:  2015 May-Jun       Impact factor: 2.630

3.  Placental elastography in second trimester preeclampsia prediction: A prospective study.

Authors:  Rajkumar Meena; Amita Malik; Swarna Jain; Achla Batra
Journal:  Ultrasound       Date:  2021-09-10

4.  Characterizing placental stiffness using ultrasound shear-wave elastography in healthy and preeclamptic pregnancies.

Authors:  Michail Spiliopoulos; Che-Ying Kuo; Avinash Eranki; Marni Jacobs; Christopher T Rossi; Sara N Iqbal; John P Fisher; Melissa H Fries; Peter C W Kim
Journal:  Arch Gynecol Obstet       Date:  2020-07-16       Impact factor: 2.344

Review 5.  Fetal membrane imaging and the prediction of preterm birth: a systematic review, current issues, and future directions.

Authors:  Vanessa Nunes; Jennifer Cross; John E Speich; Danielle R Morgan; Jerome F Strauss; Ronald M Ramus
Journal:  BMC Pregnancy Childbirth       Date:  2016-12-09       Impact factor: 3.007

6.  In vitro fibrillogenesis of tropocollagen type III in collagen type I affects its relative fibrillar topology and mechanics.

Authors:  Meisam Asgari; Neda Latifi; Hossein K Heris; Hojatollah Vali; Luc Mongeau
Journal:  Sci Rep       Date:  2017-05-03       Impact factor: 4.379

7.  Measurement of shear wave speed dispersion in the placenta by transient elastography: A preliminary ex vivo study.

Authors:  Emmanuel G Simon; Samuel Callé; Franck Perrotin; Jean-Pierre Remenieras
Journal:  PLoS One       Date:  2018-04-05       Impact factor: 3.240

8.  Measurement of elasticity of normal placenta using the Virtual Touch quantification technique.

Authors:  Size Wu; Ruixia Nan; Yueping Li; Xiaojing Cui; Xian Liang; Yanan Zhao
Journal:  Ultrasonography       Date:  2016-04-02

9.  Assessment of Placental Stiffness Using Acoustic Radiation Force Impulse Elastography in Pregnant Women with Fetal Anomalies.

Authors:  Bircan Alan; Cemil Göya; Senem Tunç; Memik Teke; Salih Hattapoğlu
Journal:  Korean J Radiol       Date:  2016-03-02       Impact factor: 3.500

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.