| Literature DB >> 23442198 |
Pieter W Smit1, Thomas van der Vlis, David Mabey, John Changalucha, Julius Mngara, Benjamin D Clark, Aura Andreasen, Jim Todd, Mark Urassa, Basia Zaba, Rosanna W Peeling.
Abstract
BACKGROUND: Syphilis causes up to 1,500,000 congenital syphilis cases annually. These could be prevented if all pregnant women were screened, and those with syphilis treated with a single dose of penicillin before 28 weeks gestation. In recent years, rapid point-of-care tests have allowed greater access to syphilis screening, especially in rural or remote areas, but the lack of quality assurance of rapid testing has been a concern. We determined the feasibility of using dried blood spots (DBS) as specimens for quality assurance of syphilis serological assays.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23442198 PMCID: PMC3586363 DOI: 10.1186/1471-2334-13-102
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Figure 1Study design diagram. The number of matching plasma and DBS samples used for each phase of the study are given in the boxes on the left and the number of matching DBS and plasma samples tested for each of the assays are given in the boxes on the right. RPR has been performed on plasma, not on DBS.
Preliminary evaluation: performance of three syphilis serological assays using Dried Blood Spots compared to plasma
| 82/96 | 363/367 | 85.4% | 98.9% | |
| (76.7–91.8%) | (97.2–99.7%) | |||
| 53/56 | 114/226 | 94.6% | 50.4% | |
| (85.1–98.9%) | (43.7–57.1%) | |||
| 46/91 | 353/354 | 50.5% | 99.7% | |
| (39.9–61.2%) | (98.4–100%) |
n= samples.
* 95% confidence interval.
† 1 TPPA DBS indeterminate excluded.
‡ 19 TPHA indeterminate results excluded.
Figure 2DBS TPPA test result of seven patients. Test outcome (− = negative, + − = indeterminate, and + = positive) was used in phase 2 of this study.
Correlation between detection of antibodies by plasma TPPA and DBS TPPA
| | | |||
|---|---|---|---|---|
| DBS TPPA | Positive | 169 | 10 | 179 |
| | Negative | 8 | 960 | 968 |
| Total | 177 | 970 | 1147* | |
sensitivity of DBS against plasma 95.5% (95% CI: 91.3–98,0%).
specificity of DBS against plasma 99.0% (95% CI: 98.1–99.5%).
* excluding 34 indeterminate results.
RPR titres of TPPA DBS positive samples
| Negative | 113 |
| 1/1 | 13 |
| 1/2 | 19 |
| 1/4 | 13 |
| 1/8 | 7 |
| 1/16 | 4 |
| 1/32 | 6 |
| 1/64 | 1 |
| >1/128 | 3 |
Rapid Plasma Reagin (RPR) results on 8 plasma samples with false negative DBS TPPA results
| BBI99P | N | N | N |
| BBI792 | N | N | N |
| BBI6GG | N | N | N |
| BBI5YI | N | N | N |
| BBI8ZC | N | 1/80 | N |
| BBI6LP | N | 1/160 | N |
| BBI6K6 | N | 1/320 | N |
| BBI6NZ | N | >1/640 | 1/64 |
N= negative.
* Quantitative TPPA.
† Quantitative RPR.