Literature DB >> 23439786

Liquid Flooded Flow-Focusing Microfluidic Device for in situ Generation of Monodisperse Microbubbles.

Ali Haider Dhanaliwala1, Johnny L Chen, Shiying Wang, John A Hossack.   

Abstract

Current microbubble-based ultrasound contrast agents are administered intravenously resulting in large losses of contrast agent, systemic distribution, and strict requirements for microbubble longevity and diameter size. Instead we propose in situ production of microbubbles directly within the vasculature to avoid these limitations. Flow focusing microfluidic devices (FFMDs) are a promising technology for enabling in situ production as they can produce microbubbles with precisely controlled diameters in real-time. While the microfluidic chips are small, the addition of inlets and interconnects to supply the gas and liquid phase greatly increases the footprint of these devices preventing the miniaturization of FFMDs to sizes compatible with medium and small vessels. To overcome this challenge, we introduce a new method for supplying the liquid (shell) phase to an FFMD that eliminates bulky interconnects. A pressurized liquid-filled chamber is coupled to the liquid inlets of an FFMD, which we term a flooded FFMD. The microbubble diameter and production rate of flooded FFMDs were measured optically over a range of gas pressures and liquid flow rates. The smallest FFMD manufactured measured 14.5 × 2.8 × 2.3 mm. A minimum microbubble diameter of 8.1 ± 0.3 μm was achieved at a production rate of 450,000 microbubbles/s (MB/s). This represents a significant improvement with respect to any previously reported result. The flooded design also simplifies parallelization and production rates of up to 670,000 MB/s were achieved using a parallelized version of the flooded FFMD. In addition, an intravascular ultrasound (IVUS) catheter was coupled to the flooded FFMD to produce an integrated ultrasound contrast imaging device. B-mode and IVUS images of microbubbles produced from a flooded FFMD in a gelatin phantom vessel were acquired to demonstrate the potential of in situ microbubble production and real-time imaging. Microbubble production rates of 222,000 MB/s from a flooded FFMD within the vessel lumen provided a 23 dB increase in B-mode contrast. Overall, the flooded design is a critical contribution towards the long- term goal of utilizing in situ produced microbubbles for contrast enhanced ultrasound imaging of, and drug delivery to, the vasculature.

Entities:  

Keywords:  Flooded input; Flow-focusing; Microfluidics; Monodisperse microbubbles; in situ production

Year:  2012        PMID: 23439786      PMCID: PMC3579535          DOI: 10.1007/s10404-012-1064-x

Source DB:  PubMed          Journal:  Microfluid Nanofluidics        ISSN: 1613-4982            Impact factor:   2.529


  43 in total

1.  Tailoring the size distribution of ultrasound contrast agents: possible method for improving sensitivity in molecular imaging.

Authors:  Esra Talu; Kanaka Hettiarachchi; Shukui Zhao; Robert L Powell; Abraham P Lee; Marjorie L Longo; Paul A Dayton
Journal:  Mol Imaging       Date:  2007 Nov-Dec       Impact factor: 4.488

2.  Stability of parallel flows in a microchannel after a T junction.

Authors:  Pierre Guillot; Annie Colin
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2005-12-05

3.  Microchannel technologies for artificial lungs: (3) open rectangular channels.

Authors:  J-K Lee; M C Kung; H H Kung; L F Mockros
Journal:  ASAIO J       Date:  2008 Jul-Aug       Impact factor: 2.872

4.  Preparation of suspensions of phospholipid-coated microbubbles by coaxial electrohydrodynamic atomization.

Authors:  U Farook; E Stride; M J Edirisinghe
Journal:  J R Soc Interface       Date:  2009-03-06       Impact factor: 4.118

5.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion.

Authors:  K Wei; A R Jayaweera; S Firoozan; A Linka; D M Skyba; S Kaul
Journal:  Circulation       Date:  1998-02-10       Impact factor: 29.690

6.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

7.  Why do the lungs clear ultrasonic contrast?

Authors:  R S Meltzer; E G Tickner; R L Popp
Journal:  Ultrasound Med Biol       Date:  1980       Impact factor: 2.998

8.  Acoustic responses of monodisperse lipid-encapsulated microbubble contrast agents produced by flow focusing.

Authors:  Mehmet Kaya; Steven Feingold; Kanaka Hettiarachchi; Abraham P Lee; Paul A Dayton
Journal:  Bubble Sci Eng Technol       Date:  2010-12

9.  Successful left ventricular opacification following peripheral venous injection of sonicated contrast agent: an experimental evaluation.

Authors:  M W Keller; S B Feinstein; D D Watson
Journal:  Am Heart J       Date:  1987-09       Impact factor: 4.749

10.  Controllable microfluidic synthesis of multiphase drug-carrying lipospheres for site-targeted therapy.

Authors:  Kanaka Hettiarachchi; Shirley Zhang; Steven Feingold; Abraham P Lee; Paul A Dayton
Journal:  Biotechnol Prog       Date:  2009 Jul-Aug
View more
  10 in total

1.  Production rate and diameter analysis of spherical monodisperse microbubbles from two-dimensional, expanding-nozzle flow-focusing microfluidic devices.

Authors:  Shiying Wang; Ali H Dhanaliwala; Johnny L Chen; John A Hossack
Journal:  Biomicrofluidics       Date:  2013-01-16       Impact factor: 2.800

Review 2.  A novel technology: microfluidic devices for microbubble ultrasound contrast agent generation.

Authors:  Hangyu Lin; Junfang Chen; Chuanpin Chen
Journal:  Med Biol Eng Comput       Date:  2016-03-25       Impact factor: 2.602

3.  Closed-loop feedback control of microbubble diameter from a flow-focusing microfluidic device.

Authors:  Yanjun Xie; Adam J Dixon; J M Robert Rickel; Alexander L Klibanov; John A Hossack
Journal:  Biomicrofluidics       Date:  2020-05-07       Impact factor: 2.800

4.  Pipe Phantoms With Applications in Molecular Imaging and System Characterization.

Authors:  Shiying Wang; Elizabeth B Herbst; Stephen D Pye; Carmel M Moran; John A Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11-09       Impact factor: 2.725

5.  Microfluidic manufacture of rt-PA -loaded echogenic liposomes.

Authors:  Madhuvanthi A Kandadai; Prithviraj Mukherjee; Himanshu Shekhar; George J Shaw; Ian Papautsky; Christy K Holland
Journal:  Biomed Microdevices       Date:  2016-06       Impact factor: 2.838

6.  Synthesis and characterization of transiently stable albumin-coated microbubbles via a flow-focusing microfluidic device.

Authors:  Johnny L Chen; Ali H Dhanaliwala; Adam J Dixon; Alexander L Klibanov; John A Hossack
Journal:  Ultrasound Med Biol       Date:  2013-12-15       Impact factor: 2.998

7.  In Vitro Sonothrombolysis Enhancement by Transiently Stable Microbubbles Produced by a Flow-Focusing Microfluidic Device.

Authors:  Adam J Dixon; John Marschner Robert Rickel; Brian D Shin; Alexander L Klibanov; John A Hossack
Journal:  Ann Biomed Eng       Date:  2017-11-30       Impact factor: 3.934

8.  Enhanced intracellular delivery of a model drug using microbubbles produced by a microfluidic device.

Authors:  Adam J Dixon; Ali H Dhanaliwala; Johnny L Chen; John A Hossack
Journal:  Ultrasound Med Biol       Date:  2013-04-30       Impact factor: 2.998

9.  Recombinant protein-stabilized monodisperse microbubbles with tunable size using a valve-based microfluidic device.

Authors:  Francesco E Angilè; Kevin B Vargo; Chandra M Sehgal; Daniel A Hammer; Daeyeon Lee
Journal:  Langmuir       Date:  2014-10-13       Impact factor: 3.882

10.  On-chip generation of microbubbles in photoacoustic contrast agents for dual modal ultrasound/photoacoustic in vivo animal imaging.

Authors:  Dhiman Das; Kathyayini Sivasubramanian; Chun Yang; Manojit Pramanik
Journal:  Sci Rep       Date:  2018-04-23       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.