Literature DB >> 23439338

Global positioning system watches for estimating energy expenditure.

Nobuko Hongu1, Barron J Orr, Denise J Roe, Rebecca G Reed, Scott B Going.   

Abstract

Global positioning system (GPS) watches have been introduced commercially, converting frequent measurements of time, location, speed (pace), and elevation into energy expenditure (EE) estimates. The purpose of this study was to compare EE estimates of 4 different GPS watches (Forerunner, Suunto, Polar, Adeo), at various walking speeds, with EE estimate from a triaxial accelerometer (RT3), which was used as a reference measure in this study. Sixteen healthy young adults completed the study. Participants wore 4 different GPS watches and an RT3 accelerometer and walked at 6-minute intervals on an outdoor track at 3 speeds (3, 5, and 7 km/hr). The statistical significance of differences in EE between the 3 watches was assessed using linear contrasts of the coefficients from the overall model. Reliability across trials for a given device was assessed using intraclass correlation coefficients as estimated in the mixed model. The GPS watches demonstrated lower reliability (intraclass correlation coefficient) across trials when compared with the RT3, particularly at the higher speed, 7 km/hr. Three GPS watches (Forerunner, Polar, and Suunto) significantly and consistently underestimated EE compared with the reference EE given by the RT3 accelerometer (average mean difference: Garmin, -50.5%; Polar, -41.7%; and Suunto, -41.7%; all p < 0.001). Results suggested that caution should be exercised when using commercial GPS watches to estimate EE in athletes during field-based testing and training.

Entities:  

Mesh:

Year:  2013        PMID: 23439338     DOI: 10.1519/JSC.0b013e31828bae0f

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  4 in total

1.  Review of Validity and Reliability of Garmin Activity Trackers.

Authors:  Kelly R Evenson; Camden L Spade
Journal:  J Meas Phys Behav       Date:  2020-06

2.  Validity of sports watches when estimating energy expenditure during running.

Authors:  Lilian Roos; Wolfgang Taube; Nadja Beeler; Thomas Wyss
Journal:  BMC Sports Sci Med Rehabil       Date:  2017-12-20

3.  Heat Acclimation Following Heat Acclimatization Elicits Additional Physiological Improvements in Male Endurance Athletes.

Authors:  Courteney L Benjamin; Yasuki Sekiguchi; Jeb F Struder; Michael R Szymanski; Ciara N Manning; Andrew J Grundstein; Elaine C Lee; Robert A Huggins; Lawrence E Armstrong; Douglas J Casa
Journal:  Int J Environ Res Public Health       Date:  2021-04-20       Impact factor: 3.390

Review 4.  Technologies That Assess the Location of Physical Activity and Sedentary Behavior: A Systematic Review.

Authors:  Adam Loveday; Lauren B Sherar; James P Sanders; Paul W Sanderson; Dale W Esliger
Journal:  J Med Internet Res       Date:  2015-08-05       Impact factor: 5.428