Literature DB >> 26245157

Technologies That Assess the Location of Physical Activity and Sedentary Behavior: A Systematic Review.

Adam Loveday1, Lauren B Sherar, James P Sanders, Paul W Sanderson, Dale W Esliger.   

Abstract

BACKGROUND: The location in which physical activity and sedentary behavior are performed can provide valuable behavioral information, both in isolation and synergistically with other areas of physical activity and sedentary behavior research. Global positioning systems (GPS) have been used in physical activity research to identify outdoor location; however, while GPS can receive signals in certain indoor environments, it is not able to provide room- or subroom-level location. On average, adults spend a high proportion of their time indoors. A measure of indoor location would, therefore, provide valuable behavioral information.
OBJECTIVE: This systematic review sought to identify and critique technology which has been or could be used to assess the location of physical activity and sedentary behavior.
METHODS: To identify published research papers, four electronic databases were searched using key terms built around behavior, technology, and location. To be eligible for inclusion, papers were required to be published in English and describe a wearable or portable technology or device capable of measuring location. Searches were performed up to February 4, 2015. This was supplemented by backward and forward reference searching. In an attempt to include novel devices which may not yet have made their way into the published research, searches were also performed using three Internet search engines. Specialized software was used to download search results and thus mitigate the potential pitfalls of changing search algorithms.
RESULTS: A total of 188 research papers met the inclusion criteria. Global positioning systems were the most widely used location technology in the published research, followed by wearable cameras, and radio-frequency identification. Internet search engines identified 81 global positioning systems, 35 real-time locating systems, and 21 wearable cameras. Real-time locating systems determine the indoor location of a wearable tag via the known location of reference nodes. Although the type of reference node and location determination method varies between manufacturers, Wi-Fi appears to be the most popular method.
CONCLUSIONS: The addition of location information to existing measures of physical activity and sedentary behavior will provide important behavioral information.

Entities:  

Keywords:  context; global positioning system; real-time locating system; sitting; wearable camera

Mesh:

Year:  2015        PMID: 26245157      PMCID: PMC4705371          DOI: 10.2196/jmir.4761

Source DB:  PubMed          Journal:  J Med Internet Res        ISSN: 1438-8871            Impact factor:   5.428


Introduction

Physical activity has a long-established relationship with several chronic conditions including diabetes, heart disease, and certain forms of cancer [1]. Recent evidence suggests that sedentary behavior carries deleterious effects on health outcomes independent of moderate-to-vigorous physical activity (MVPA) in young people [2] and adults [3], although this is not a uniform finding [4]. Sedentary behaviors are defined as any waking activity with an energy expenditure of ≤1.5 metabolic equivalents (METs) while in a sitting or reclining position [5]. A paradigm shift is underway toward an increasing appreciation of the importance of reducing sedentary time alongside increasing physical activity [6]. Within the behavioral epidemiology framework [7], the location of a behavior may influence the correlates of the behavior and the intervention strategies needed to change behavior. Discerning the varying contribution of multiple locations to physical activity and sedentary time will allow researchers to target interventions to locations which are associated with the lowest levels of physical activity or highest levels of sedentary time. Understanding the contribution of multiple locations to health behaviors first requires the accurate measurement of location, as suggested by the behavioral epidemiology framework [7,8]. Sedentary behavior and physical activity differ in the domains and locations in which they are likely to occur. Sedentary time is likely, though not exclusively, to occur indoors at the home, at work or school, or in leisure pursuits such as eating a meal or going to the cinema. Conversely, MVPA may occur through active transport, housework, or purposeful exercise. This can be illustrated through the close link between adults, on average, spending approximately 90% of time indoors [9,10] and approximately 60% of time in sedentary activities [11]. The large proportion of time spent indoors and the increasing research focus on sedentary behavior suggest that an accurate measure of where behavior occurs indoors would be particularly valuable. Determining where physical activity and sedentary time are performed will provide valuable information in isolation; however, it can also act in a synergistic manner. For example, much recent effort has focused on the use of complex pattern recognition techniques to determine the mode or type of activity being performed from raw acceleration data. Depending on the classification method used, classification accuracies between 50% and 90% have been achieved [12]. Given the probabilistic nature of these activity classification methods, the inclusion of location-based data into the current algorithms may provide greater levels of accuracy. For instance, the likelihood of stair climbing is greatly increased if an individual is near a staircase. Similarly, context-sensitive questioning via ecological momentary assessment (EMA) [13] can be enhanced by using location to trigger desirable questions in place of time-based cues. Furthermore, measurement of indoor location could benefit research into the correlates of physical activity or sedentary behavior. For example, the presence of a television set in a child’s bedroom may be a correlate of higher screen time [14]; however, this may be a stronger correlate for those who spend more time in their bedrooms. Establishing how much time a child spends in their bedroom via objective indoor location could, therefore, fully elucidate the strength of this correlate. Thus, the accurate measurement of location could greatly enhance several areas within physical activity and sedentary behavior research, both in and of itself and as an adjunct to other research areas. Individuals may be able to accurately report the broad location of their physical activity and sedentary behavior [15]; however, self-report location instruments are unable to provide detailed and temporally patterned location information. Objective monitoring could, therefore, provide a more robust means to measure the location of physical activity and sedentary behavior. To date, time indoors has been inferred through the lack of a global positioning system (GPS) signal [16] or through the use of a light (lux) sensor incorporated into activity monitors [17]. However, these methods are only able to differentiate indoor from outdoor and do not provide room- or subroom-level location. Alongside measures of outdoor location, there is, therefore, a need for measures of room- and subroom-level indoor locations, which are feasible for use in this field of research. This review aims to provide an overview of devices and technology currently used, or that could potentially be used, to assess the indoor or outdoor location of physical activity and/or sedentary behavior.

Methods

Search Strategy

Search strategies to identify potentially relevant articles were built around three key groups of keywords: behavior, measurement, and context. Key terms were as follows: sedentary lifestyle, sedentary lifestyles, sedentary behav*, screen time, seden*, sitting time, motor activity, motor activities, physical activity, or activities of daily living; measur*, assess*, patterns, monitor, or sensor; and context*, setting, location, mode, domains, or environment. Scopus, Web of Science, PubMed, Institute of Electrical and Electronics Engineers (IEEE), and OpenGrey were searched using the key terms up to February 4, 2015. Subsequently, forward and backward searching of included articles (ie, references and articles citing the included article) was conducted to identify any further eligible articles. In addition, manual searches of personal files were conducted.

Inclusion and Exclusion Criteria

To be included in this review, studies were required to meet the following criteria: (1) be published in the English language, (2) either describe a tool used to measure the location of physical activity and/or sedentary behavior or provide sufficient information to discern whether the instrument could be modified to measure location, and (3) be a portable/wearable tool. Technologies were required to be portable or wearable to ensure that the technology is always with the participant and that the scope of the review was not so broad as to be unmanageable by including nonwearable technologies (eg, closed-circuit television [CCTV]). A minimum of one part of the measurement system, not the whole system, was required to be wearable/portable for inclusion. For example, GPS systems consist of a wearable unit and orbiting satellites (ie, one part of the system is wearable but the whole system also consists of unwearable components). Wearable technologies is also an area which is experiencing rapid growth in the consumer sector, as technology increasingly becomes smaller, more powerful, and multi-purpose. Wearable technologies, therefore, give this review a contemporary positioning. No date restriction was placed on search results. Studies erroneously defining sedentary behavior as the absence of sufficient physical activity rather than activities undertaken in a sitting or reclined position [5], were treated as physical activity studies.

Identification of Relevant Studies

Titles and then abstracts of identified articles were screened to determine eligibility based on the above inclusion criteria. Titles and abstracts which did not meet the inclusion criteria were excluded. Following this, the full text of any potentially relevant article was obtained for full reading to determine conformity to the inclusion criteria. A subsample of potentially relevant articles retrieved for full-paper screening were extracted by a second author (JPS) to determine interrater agreement. If any discrepancies arose, these were resolved by discussion between authors. Interrater agreement was high (Cohen’s kappa = .81).

Data Extraction and Synthesis

Data of eligible papers was extracted via standardized forms developed for this review. All available information was extracted. Identified devices which assessed where physical activity and sedentary behavior occur were tabulated to highlight the available literature in this research area and to showcase the array of measurement technologies.

Internet Search Engines

To ensure that the widest possible range of devices were included, systematic searches of Internet search engines were performed for devices and technologies that are able to measure location but may not have made their way into the published research to date. This was necessary due to the relatively slow pace of research and publication compared to the pace of technological advance (ie, new research papers may use old technology which has been surpassed by newer models). Google, Bing, and Yahoo were searched using the following key terms: RTLS (real-time locating system), GPS tracking device, RFID (radio-frequency identification) tracking, wearable camera, wearable GPS, and wearable RFID. These search terms were chosen based on the results of the academic literature searches. Specialized software was used to export the first 300 results of each search to Microsoft Excel. This ensured that the results were unaffected by the changing algorithms of search engines. Searches were completed on February 4, 2015. The retrieved website addresses were screened to determine eligibility. Only manufacturer websites were included to ensure the accuracy of the information. All other websites, including blogs and consumer review websites, were excluded. Eligible websites were then browsed for location monitoring devices. Only devices and full integrated systems which are ready to use (ie, not bespoke) were included in an attempt to address the practicalities of deployment to assess where physical activity and sedentary time occur. The specifications of these devices were then extracted using standardized forms developed for this review. If available, specifications were obtained from device manuals. If device manuals were not available, any specifications shown on the website regarding the device were extracted. Only available information was extracted (ie, gaps in tables indicate a lack of available information). By note of caution, readers should be mindful that device characteristics, as supplied by manufacturers, are often generated under ideal conditions. Real-world pilot-testing with participants may, therefore, be required to establish real-world device characteristics.

Results

The number of research papers included and excluded at each stage of the systematic review process is shown in Figure 1. This review began with 61,009 potentially eligible papers, eventually resulting in the full inclusion of 98 papers. A further 90 papers were then identified through reference searching, citation tracking, and the searching of personal files.
Figure 1

Flowchart of study selection process.

A breakdown by year and technology is depicted in Figure 2. This review found 12 types of technology capable of assessing where physical activity and sedentary behavior occur. GPS was the most widely used location monitoring technology, comprising 119 (63.3%) [16,18-134] of the total 188 papers. Wearable cameras and RFID were the second- and third-most popular forms of location technology, contributing 23 (12.2%) [18,19,135-156] and 20 (10.6%) [157-177] studies, respectively, out of 188. The remaining 9 technologies each contributed a small number of studies (8 [4.3%] or less) to the total sample [178-200]. GPS has the longest history of use, initially being used within sports science in 1997. Conversely, wearable cameras and Wi-Fi-based localization technologies appear to be the most recent debut within research.
Figure 2

Number of studies published each year covering different types of technology. A total of 12 kinds of technology were found during the course of this review.

Selective details of devices used within research are shown in Table 1 (wearable cameras), Table 2 (GPS), and Table 3 (other). A complete version of Table 2 is available as Multimedia Appendix 1.
Table 1

Summary of wearable camera systems used in published research to date.

Mana ModelI/Ob BLc,hCRd,mpDime,cmWeight,kg or gWear siteSFf,FPSg Refsh, notes
Natural-Point, IncOptiTrack- Prime 17WIndoorN/Ai 1.712.6x12.6x11.01.32 kgN/A30-360[135]
ViconMotion capture systemBoth(most indoor)N/A≤16N/AN/AN/A≤1000[136,137]
PrototypeeButtonBoth~10N/A6.2diameter42 gPin onto shirt10[138-140]Not yet commer-cialized
PrototypePrototypeWrist-SenseBoth~7N/AN/AN/AWrist6[141,142]
MicrosoftSenseCam(Vicon Revue)Both≤16N/AN/AN/ALanyard around neckChange in sensor readings[18,19,143-155] Available as Auto-grapher
LooxcieLooxcie 2Both1-4N/A2.31x1.70x8.4622 gN/A15/30[156]

aMan: manufacturer

bI/O: Indoor/outdoor

cBL: battery life

dCR: camera resolution

eDim: dimensions

fSF: sampling frequency

gFPS: frames per second

hRefs: references

iN/A: not applicable

Table 2

Summary of Global positioning systems used to date in published research (see Multimedia Appendix 1 for the full version of this table).

Mana ModelBattery life,h, days, or weeksDimb, cm or mmWeight,gWear siteCold start time,s or HzStorage, points, MB, or, GBReferences
GarminForetrex 20115 h8.4x4.3x1.8 cm78Wrist45 s10,000 points[16,20-31]
GarminForerunner 305Typically10 h5.3x 6.8x1.7 cm77Wrist45 sN/Ac [32-35]
GarminForerunner 20510 h53x69x18 mm77Wrist45 s72,000points[25,30,42-45]
Garmin60N/AN/AN/APocket of back-pack0.5 HzN/A[46,47]
Telespial SystemsTrackstick II16-36 h,2 days-1 week in power save11.4x3.1x1.9 cmN/AN/AMaximum of 52 s1 MB[52,53]
GlobalSatDG10020-24 hN/AN/AWaist5, 15, or 30 s50,000 points[25,47,54-59]
GPSportsSPI ELITEN/AN/AN/ABack harness1 HzN/A[60-69]
GPSportsSPI PRON/AN/AN/ABack harness5 HzN/A[71-74]
GPSportsSPI 10N/AN/AN/ABack harness1 HzN/A[65,66,73,75-77]
Catapult InnovationsMinimaxX5 h8.8x5.0x1.9 cm67Back harness 1 GB[62,73,78-87]
Telespial SystemsSuper4-8 daysN/AN/AWaist5 or 15 sN/A[88,89]
QstarzBT1000X42 h72x47x20 mm65Pouch on belt35 s, 5 s, or 15 s400,000 points[18,19,30,59,90-104,134]
GlobalSatBT33525 hN/AN/AWaist30 sN/A[110-114]

aMan: manufacturer

bDim: dimensions

cN/A: not applicable

Table 3

Summary of other measures used in published research to date.

Type of measureIndoor/outdoorReferences
Radio-frequency identificationIndoor[157-177]
Wireless localizationIndoor[178-183]
Technology-assisted ecological momentary assessment/experience samplingBoth[184-191]
Integrated circuit tagsIndoor[192,193]
Ultrasonic (Bat system)Indoor[194]
Cellular networksOutdoor, but works indoor[195]
BluetoothIndoor[196]
Social media check-inBoth[197]
UltrasoundIndoor[198,199]
Pedestrian dead reckoning systemIndoor[200]
Tables 4-6 show selective characteristics of the results of the Internet search engine searches for wearable cameras, RTLS, and GPS, respectively. Complete versions of Tables 5 and 6 are available as Multimedia Appendices 2 and 3. These searches found 21 wearable cameras [201-214], 78 RTLS tags from 35 companies [215-249], and 81 GPS devices [250-286]. GPS devices were marketed for a variety of purposes, including the tracking of children by parents, elder monitoring to limit wandering, and the tracking of young drivers. RTLS companies positioned their products as suitable for asset management applications in warehouses and, to a lesser extent, equipment and patient tracking in health care settings. Wearable cameras were targeted toward extreme sports, life logging, and law enforcement applications.
Table 4

Summary of commercially available wearable cameras unused in research to date.

Manufacturer,referenceModelBattery life of wearable component,h or minDimensions,mm, in, or cmWeight,g or ozWear site
Autographer [201]N/Aa 10 h37.40x90.00x22.93 mm58 gClip or lanyard
Narrative (formally Memoto) [202]
ClipN/A36x36x9 mm20 gClip or lanyard
Clip 2 (released spring 2015)N/AN/AN/AN/A
MeCam [203]
Classic80 min continuous1.75x0.50 in1 ozClip or necklace
MeCam HD60-120 min2x2 in2.5 ozN/A
uCorder [204]
Pockito IRDC260-R≤75 min2.50x1.25x0.50 inN/AN/A
Pockito IRDC260-B≤75 min2.50x1.25x0.50 inN/AN/A
Pockito IRDC150≤2 h1.1x0.6x3.5 inN/AN/A
Pockito IRDC250≤2 h1.1x0.6x3.5 inN/AN/A
ParaShoot [205]2.1N/A45x4x15 mm1.5 ozClip
Spy Emporium [206]Spy hidden camera glasses1-2 h160x40x40 mmN/AGlasses/ on face
VIEVU [207]
VIEVU 22.5 h recording,1.5 h streaming1.90x1.90x0.75 in2.4 ozClip
LE3≤5 h3.00x2.10x0.85 in2.8 ozClip
Panasonic [208]
WV-TW310L5 h continuous45x75x41 mm210 g
WV-TW310S5 h continuous45x75x41 mm160 g
meMINI [209]N/A3.5 hN/AN/ALanyard
Pivothead [210]N/AN/AN/AN/AGlasses/ on face
Nixie [211]N/AN/AN/AN/AWrist (detaches to become camera)
CA7CH [212]LightboxN/A38x38x10 mm30 gClip
ELMO USA [213]QBIC-MSI2 h2.14x2.40x1.57 in95 gLanyard
Vidcie [214]Lookout QUB1 h (8 h with battery pack)4.8x4.8x1.5 cm37 gClip

aN/A: not applicable

Table 6

Summary of commercially available global positioning systems unused in research to date (see Multimedia Appendix 3 for the full version of this table).

ManufacturerModelBattery life of wearable component,days, weeks, months, or hDimensions,in, cm, or mm
Trackstick [250]
Trackstick mini3-14 days3.50x1.50x0.38 in
Trackstick II16 h-2 days (AAA)4.50x1.25x0.75 in
Super Trackstick3 days-3 weeks (AAA)4.50x1.25x0.75 in
Trackershop-UK [251]Pro-pod514-15 days6.35x4.00x2.50 cm
Gotek7 [252]
Prime 1.010 days normal; ≤12 months with 1 update per dayN/Aa
Prime 2.015 days normal; ≤14 months (1 per day)65x42x25 mm
Trackinapack [256]
Advanced≤10 days2.63x1.38x0.79 in
Advanced plus≤15 days2.50x1.50x0.79 in
TracLogik [259]
Guardian GPS100-220 hours67.8x37.0x20.0 mm
Guardian pro GPS2-14 days62.5x40.0x25.0 mm
Covert 200010-15 days61x34x31 mm
Loc8tor [261]N/A≤9 months in power save;3-14 days normally68x36x20 mm
LandAirSea [269]
Silvercloud realtime GPS tracker5-6 days at 2 h per day3.90x2.26x0.90 in
Tracking key pro2 weeks (4 h), 4 weeks (2 h), 6 weeks (1 h per day)3.01x1.95x1.40 in
GTX Corp [273]
Prime AT≤16 days67x37x20 mm
Smart sole2-3 daysDepends on show size
Nike [276]Sportwatch GPS8 h with average use1.5x10.1x0.6 in
Garmin [277]
Forerunner 6206 weeks (watch) 10 h (training)45.0x45.0x12.5 mm
Forerunner 2206 weeks (watch) 10 h (training)45.0x45.0x12.5 mm
Tactix50 h (5 weeks in watch mode)49x49x17 mm
Fenix 220 h ( 5 weeks in watch mode)49x49x17 mm
Trax [280]Trax1 day38x55x10 mm
Personal GPS Trackers [282]
Personal GPS Tracker≤7 days65x40x18 mm
Mini GPS Tracker2-4 days58x22x11 mm

aN/A: not applicable

Table 5

Summary of commercially available real-time locating systems unused in research to date (see Multimedia Appendix 2 for the full version of this table).

Manufacturer, referenceModelInfrastructure/ methodDimensions,mm, in, or cmAccuracy, m, cm, or ft
Ekahau [215]
A4Wi-Fi, RSSIaand triangulation45x55x19 mm1 m
B4Wi-Fi, RSSI and triangulation60.0x90.0x8.5 mm1 m
W4Wi-Fi, RSSI and triangulation51.5x50.0x17.5 mm1 m
Ubisense [216]
Series 7000 industrialUWBb, TOAc, AOAd 71x64x47 mm15 cm
Series 7000 compactUWB, TOA, AOA38.0x39.0x16.5 mm15 cm
Series 7000 slim tagUWB, TOA, AOA83x42x11 mm15 cm
Series 700 intrinsically safe tagUWB, TOA, AOA38.0x39.0x25.5 mm15 cm
Series 9000 compact tagUWB, TOA, AOA38.0x39.0x16.5 mm15 cm
Zebra [218]
WhereTag IVWi-Fi, TDOAe 43.7x66.0x21.3 mm2 m
WhereTag IIIWi-Fi, TDOA21x66x44 mm
Sonitor [222]Whole systemWi-Fi, ultrasound, RSSIN/Af 1 ft
Secure Care [225]ENVisionITWi-FiN/A30 cm
Mojix [226]eLocationPassive RFIDg N/AWithin1 m
TempSys [228]Fetch SystemRFhand ultrasound, TDOAN/A0.5 m
Awarepoint [229]
Asset tagsZigBee1.8x1.3x0.5 inUp to bay level
Wearable tagZigBee1.8x1.3x0.5 in
Nebusens [232]Sirius QuantumZigBee22.00x32.72x5.00 mm1 m
Essensium [233]Mobile nodesWide over narrowband RF, TWRi, TOFj 19.8x8.8 cmTypically 50 cm
PLUS Location [234]
R1 badge tagUWB, TDOA38.0x78.0x9.6 mm<1 m
R2 tagsUWB, TDOA87x42x10 mm<1 m
Purelink [239]Personnel tracking tagRFID85x54x4 mm2 m
Sanitag [240]
Staff tagRF, RSSI, TOF90x61x5 mm2.5 m
Patient tagRF, RSSI, TOF43x36x10 mm2.5 m
OpenRTLS [242]TagUWB, TDOA, TWR66x44x17 mm10 cm

aRSSI: received signal strength indicator

bUWB: ultra wide band

cTOA: time of arrival

dAOA: angle of arrival

eTDOA: time difference of arrival

fN/A: not applicable

gRFID: radio-frequency identification

hRF: radio frequency

iTWR: two-way ranging

jTOF: time of flight

Summary of wearable camera systems used in published research to date. aMan: manufacturer bI/O: Indoor/outdoor cBL: battery life dCR: camera resolution eDim: dimensions fSF: sampling frequency gFPS: frames per second hRefs: references iN/A: not applicable Summary of Global positioning systems used to date in published research (see Multimedia Appendix 1 for the full version of this table). aMan: manufacturer bDim: dimensions cN/A: not applicable Summary of other measures used in published research to date. Summary of commercially available wearable cameras unused in research to date. aN/A: not applicable Summary of commercially available real-time locating systems unused in research to date (see Multimedia Appendix 2 for the full version of this table). aRSSI: received signal strength indicator bUWB: ultra wide band cTOA: time of arrival dAOA: angle of arrival eTDOA: time difference of arrival fN/A: not applicable gRFID: radio-frequency identification hRF: radio frequency iTWR: two-way ranging jTOF: time of flight Summary of commercially available global positioning systems unused in research to date (see Multimedia Appendix 3 for the full version of this table). aN/A: not applicable Flowchart of study selection process. Number of studies published each year covering different types of technology. A total of 12 kinds of technology were found during the course of this review.

Discussion

Principal Findings

This systematic review sought to identify tools which have been used, or could be modified for use, to assess where physical activity and sedentary behaviors occur. This review identified 188 research papers which used 12 different types of technology. The most widely used technology was GPS with 119 publications [16,18-134], followed by wearable cameras and RFID with 23 [18,19,135-156] and 20 [157-177] publications, respectively. The remaining 9 types of technology each contributed a small number of studies to the total sample [178-200]. However, it should be noted that a number of these were bespoke or prototype systems; this is particularly true of RFID, integrated circuit (IC) tag systems, and various communication protocols for wireless localization. Systematic grey searches identified 21 wearable cameras [201-214], 78 RTLS tags [215-249], and 81 GPS devices [250-286]. By only including devices which are "ready to use," we sought to address the practicalities of deployment and limit the inclusion of bespoke technologies. Combined with the devices used within research papers to date, we identified a total of 263 devices. The history, principles of use, and the applications for GPS, RTLS, and wearable cameras will now be discussed in greater detail.

Global Positioning System

Originally developed by the United States Department of Defense, the GPS system consists of 24 satellites orbiting Earth. These satellites transmit signals to GPS receivers and are able to determine the location, direction, and speed of the receiver based on trilateration between three or more satellites [287]. Due to the original military application of GPS, a deliberate error was embedded into the system to reduce the risk of enemy forces using the system. This deliberate error was removed in the year 2000, thus making the system available to civilian users. The use of GPS has since proliferated into areas such as criminal offender tracking, vehicle tracking, and vehicle navigation. Such has been the widespread adoption of GPS, that the European Union is currently investing substantial amounts of money into its own satellite system to ensure it is not reliant on American satellites. Early GPS devices possessed limited battery life and memory capacity and form factors unsuitable for long periods of wear. Thus GPS devices were first used for sports applications before making their way into health research. The earliest GPS study in a sporting domain was conducted in 1997 [132]. It was found from this initial evaluation that GPS could be used to assess human locomotion [132]. Following this early study, GPS has been used to assess movement characteristics in sports such as Australian football [66], orienteering [49], hockey [63], and rugby [72]. These studies have generally found GPS to be a suitable measure of movement parameters in sport, such as speed and distance. Physiological measures such as heart rate are often included alongside GPS to provide further data on the demands of a particular sport. These devices are often worn on the back via a custom-made vest and are, therefore, unlikely to be suitable for long-term wear. These sports studies, therefore, provide little insight into the applicability of GPS for assessing free-living physical activity. The earliest study to use GPS to investigate free-living physical activity was conducted in 2005 [22]. The GPS units were found to provide valid and reliable measures of location when compared to a known geodetic point [22]. Following the validation of these units, a small pilot study examined the feasibility of integrating GPS, geographic information system (GIS), and accelerometer data. It was found that GPS and accelerometer data could be successfully integrated, with GPS data available for 67% of all MVPA time [22]. Accelerometer, GIS, and GPS data have since been successfully integrated in further studies to assess active commuting to school [16] and time spent outdoors after school [20]. In reviewing 24 studies which use GPS in physical activity research [288], GPS data loss was found to be highly correlated with device wear time (r=.81, P<.001). Common reasons for data loss include signal dropout, limited battery power, and poor protocol adherence [288]. Due to devices requiring a line of sight to the orbiting satellites, signal dropout can occur when this line of sight is broken. The necessity for GPS devices to have a line of sight to at least three orbiting satellites also results in GPS only receiving signal within certain indoor environments, such as a single-story building with a wooden roof or high-story building with large windows. Even under these circumstances, GPS is unable to determine room- or subroom-level indoor location. Participants are often required to remain stationary outside before commencing a journey to ensure that the GPS device can acquire satellite signal, failure to adhere to this can result in data loss. While GPS can be used to successfully augment accelerometer measurement of physical activity, several shortcomings need to be addressed. There is currently no established approach to the analysis and interpretation of GPS data [287]. Guidelines and common data analysis programs for the capture and analysis of GPS data, such as the Personal Activity and Location Measurement System (PALMS), are therefore highly useful in standardizing approaches. Due to requiring a clear line of sight to orbiting satellites, GPS is most suitable for assessing outdoor location. However, up to 90% of our time is spent indoors [9,10]. The ability to assess where physical activity and sedentary time occur in an indoor environment would allow the formation of a more comprehensive behavioral profile which incorporates contextual information alongside accelerometry-measured intensity and duration.

Wireless Localization

Wireless localization technology has been commercialized under the umbrella term real-time locating systems. Used in health care [289] and warehouse environments, RTLS systems are able to assess the location of people or assets within an indoor environment. Many RTLS devices are commercially available (see Table 5 and Multimedia Appendix 2). All of these devices function on the principle of determining the location of a mobile component via the known location of fixed components, though the method of determining location and the type of fixed component vary between manufacturers. Interested readers are referred elsewhere for detailed technological reviews of wireless localization [290-293]. The fixed components of RTLS systems also vary between RTLS manufacturers. Some manufacturers, such as AeroScout, require the installation of proprietary fixed reference points. Others, such as the Ekahau system, are able to utilize existing Wi-Fi points within buildings as fixed reference points and, therefore, do not require the installation of infrastructure. Several manufacturers also provide infrared (IR) location beacons for increased location accuracy in areas of poor signal strength. Hardware of the Ekahau RTLS system is shown in Figure 3. The location of the mobile component of the RTLS system, worn by an individual or placed on equipment, is then relayed back to software supplied with the RTLS system. This software requires a floor plan of the environment being monitored; the location of the mobile component is then viewed on this floor plan or as an x and y coordinate. RTLS systems, therefore, function in much the same manner as GPS: providing x and y coordinates rather than longitude and latitude. The manufacturers of several RTLS systems suggest that their systems are capable of handling hundreds of mobile tags simultaneously. Manufacturers state that RTLS systems are generally accurate to within 2 to 3 meters.
Figure 3

Hardware components of the Ekahau real-time locating system (RTLS) [214]. Wearable T301W white wrist tags are shown in a charging cradle; infrared beacons are shown on either side of the charging cradle.

However, RTLS systems are not without limitations. Due to their predominant use in the tracking of patients and equipment, many RTLS systems are configured for real-time monitoring and require slight modification to generate a log of coordinates for any later integration with other data streams. At present, RTLS systems are not being used in physical activity or sedentary behavior research; therefore, the feasibility of incorporating RTLS data with accelerometry is unknown. The RTLS software requires the manual setting of the scale of the floor plan and, therefore, introduces possible human error into the system. Despite this, RTLS could potentially be used within physical activity and sedentary behavior research to answer a number of research questions which are currently assessed via self-report methods. For example, RTLS, alongside accelerometry, could provide location information to assess whether youngsters in a daycare center are more likely to be active when they are near equipment such as a sandbox or when they are near other active youngsters. Likewise, if researchers are undertaking a standing desk intervention to reduce sitting time, participants are currently often asked to self-report how much time they spend at their desk. The amount of time the participant spends at their desk may impact any possible reduction in sitting time due to the standing desk. With RTLS, researchers would be able to objectively determine the amount of time their participants were at their standing desk and thus determine the success, or otherwise, of the intervention with greater certainty. Determining the indoor location of physical activity and sedentary behavior via RTLS may also be an important research finding in itself. For example, within an elderly care home environment, RTLS could be used to assess whether individual residents are more sedentary alone in their bedrooms or when mixing with other residents in communal areas. Depending on the findings, some residents may then be best suited to an individual intervention focusing on bedroom-based sedentary behavior while other residents may be more suited to a group intervention focusing on communal area sedentary behavior. Hardware components of the Ekahau real-time locating system (RTLS) [214]. Wearable T301W white wrist tags are shown in a charging cradle; infrared beacons are shown on either side of the charging cradle.

Wearable Cameras

Recent interest has accumulated in the use of wearable cameras in physical activity and sedentary behavior research, mirroring the growth of the life-logging and quantified-self communities. However, several of the wearable cameras identified in this review appear to have limited public health utility due to very short (eg, 1.5 hours) of battery life. The most popular wearable camera in a research setting is the Microsoft SenseCam. Worn on a lanyard around the neck and containing sensors such as passive infrared, accelerometer, and gyroscope, this device automatically captures a first-person picture at a frequency of approximately 20 seconds. The device has a battery life of approximately 16 hours with sufficient memory capacity to store approximately 32,000 images [294]. From initial small-scale pilot studies, it appears that images generated from wearable cameras are a feasible means of assessing active travel behavior [144,294]. Wearable cameras, therefore, provide broader contextual information; however, they can also be used to infer location. Commercially available wearable cameras, such as the Autographer, also provide GPS coordinates alongside the photograph. Two of the most popular wearable cameras are shown in Figure 4.
Figure 4

Hardware of two wearable cameras. Shown on the left is the Narrative clip [201] and on the right the Autographer [200].

Unlike pure location measurement technologies such as GPS and RTLS, wearable cameras are able to provide broader contextual information based on the generated images. For example, a succession of images may show a television set. From this, it could be identified that the participant is watching television. Likewise, a succession of images may show a group of people of a similar age to the participant which researchers may be able to classify as time spent with friends; this is important as an individual’s friends may play a role in shaping physical activity behaviors [295]. Despite the encouragement offered by these initial studies, significant ethical, privacy, and analytical issues remain. There is a possibility that participants may be wearing the device during situations in which they do not wish to be photographed. To overcome this, the device allows the user to turn off the device for several minutes should they require privacy. There is also the possibility that the device may take pictures of an individual that participants encounter who does not wish to be photographed. Linked to this is the possibility that individuals may be wearing the device in situations that are unsuitable for photography, such as dropping off or picking up children from school. In an effort to overcome some of these issues [296], an ethical framework has been proposed for the use of wearable cameras in research. The framework includes the issues of informed written consent from participants, privacy and confidentiality, nonmaleficence, and the autonomy of third parties [296]. Alongside these privacy issues is the issue of data analysis. Current data analysis methods are laborious, involving the manual trawling and coding of images. For long-term monitoring this may prove to be prohibitive in the adoption of wearable cameras. Pattern recognition algorithms to semiautomate this process are available from computer scientists; however, there is a need for these to be integrated into device software in a manner which is suitable for end users. Despite these issues, wearable cameras can be used to assess where behavior occurs both indoors and outdoors and may, therefore, be able to supplement GPS to provide a greater range of contextual information. The preceding discussion of GPS, RTLS, and wearable cameras highlights the principles, limitations, and use in physical activity and sedentary behavior research of each of these three technologies. GPS is the dominant technology used within research to date to assess where physical activity and sedentary time occur. However, the development of RTLS and wearable cameras offers the possibility to incorporate these technologies alongside GPS and accelerometry to provide a more comprehensive behavioral profile which fully elucidates the context, intensity, and duration of the behavior. The present systematic review also identified several other location monitoring technologies, such as RFID and IC tags, that are less "ready to use" than the three main technologies discussed. While these technologies, particularly RFID, may have a substantial research base behind them, there appears to be no "off the shelf" complete system which is readily purchasable for location tracking. The ability to assess where behavior occurs in an indoor environment may be particularly elucidating for sedentary time. With the ability to assess where sedentary behavior occurs at work (eg, in a meeting room or at a desk) and at home (eg, sofa, desk, or dining table), behavioral researchers would possess a more comprehensive profile of the context in which sedentary behavior occurs, which could further illuminate the most common modes of sedentary behavior. It is also worth briefly considering available technologies which were not included in this systematic review, largely due to a lack of wearability. Bluetooth low energy (BLE) proximity systems have recently gained in popularity in certain applications. Many of these systems are primarily aimed toward retail applications for the purpose of proximity marketing. In this scenario, small BLE beacons are placed around a retail environment. The customer, as they are perusing the store with a BLE-enabled device such as a mobile phone, then receives targeted marketing and discount offers to their phone based on their proximity to the beacons. For example, when the customer is perusing the carbonated drinks aisle in a supermarket, an offer may be sent to their phone for a particular brand of drink. These systems offer the potential to install BLE beacons within an indoor environment and determine location based on proximity to the beacons. Of particular note is the recent miniaturization of BLE beacons to the size of a sticker, so suitably small that it may unobtrusively be attached to items such as chairs, bicycles, and sports equipment. This novel "nearables" equipment offers the potential to assess the location and type of behavior. Hardware of two wearable cameras. Shown on the left is the Narrative clip [201] and on the right the Autographer [200].

Conclusions

This systematic review sought to identify tools which have been used or could be used to asses where physical activity and sedentary time occur. We identified 188 research papers, of which 119 used GPS and 23 used wearable cameras. A total of 76 location tracking devices or systems were used. Systematic Internet search engine searches found 21 wearable camera models, 78 RTLS tags, and 81 GPS devices. This gave a cumulative total of 263 location tracking devices or systems. GPS is the dominant form of location tracking used within physical activity research to date. While GPS is a valid measure of outdoor location, it is unable to be used within an indoor environment. Recent developments in wearable cameras and RTLS systems have ensured that tools are now available which offer the potential to assess where physical activity and sedentary behaviors occur indoors. Thus, these tools can provide further contextual information, alongside GPS, when used in conjunction with measures of physical activity and sedentary behavior such as accelerometers. Issues and limitations of each technology were identified, including privacy, data analysis and interpretation, and common data processing methodologies. The integration of accelerometry, GPS, and a technology capable of assessing indoor location would provide researchers with the ability to assess the indoor and outdoor location of physical activity and sedentary behavior. Future research should, therefore, investigate the feasibility of incorporating these technologies, with particular reference to the wearability of the devices, the integration of data streams, and the generation of meaningful behavioral outcomes.
  157 in total

1.  Validity and reliability of GPS for measuring distance travelled in field-based team sports.

Authors:  Adrian J Gray; David Jenkins; Mark H Andrews; Dennis R Taaffe; Megan L Glover
Journal:  J Sports Sci       Date:  2010-10       Impact factor: 3.337

2.  Combined metabolic gas analyser and dGPS analysis of performance in cross-country skiing.

Authors:  Peter Larsson; Karin Henriksson-Larsén
Journal:  J Sports Sci       Date:  2005-08       Impact factor: 3.337

3.  The validity and reliability of a global positioning satellite system device to assess speed and repeated sprint ability (RSA) in athletes.

Authors:  José C Barbero-Alvarez; Aaron Coutts; Juan Granda; Verónica Barbero-Alvarez; Carlo Castagna
Journal:  J Sci Med Sport       Date:  2009-05-14       Impact factor: 4.319

Review 4.  Activity identification using body-mounted sensors--a review of classification techniques.

Authors:  Stephen J Preece; John Y Goulermas; Laurence P J Kenney; Dave Howard; Kenneth Meijer; Robin Crompton
Journal:  Physiol Meas       Date:  2009-04-02       Impact factor: 2.833

5.  Monitoring mobility in older adults using global positioning system (GPS) watches and accelerometers: a feasibility study.

Authors:  Sandra C Webber; Michelle M Porter
Journal:  J Aging Phys Act       Date:  2009-10       Impact factor: 1.961

6.  Physical Activity Recognition Based on Motion in Images Acquired by a Wearable Camera.

Authors:  Hong Zhang; Lu Li; Wenyan Jia; John D Fernstrom; Robert J Sclabassi; Zhi-Hong Mao; Mingui Sun
Journal:  Neurocomputing       Date:  2011-06-01       Impact factor: 5.719

7.  Combining GPS with heart rate monitoring to measure physical activity in children: A feasibility study.

Authors:  J Scott Duncan; Hannah M Badland; Grant Schofield
Journal:  J Sci Med Sport       Date:  2008-11-25       Impact factor: 4.319

8.  Context-Specific Outdoor Time and Physical Activity among School-Children Across Gender and Age: Using Accelerometers and GPS to Advance Methods.

Authors:  Charlotte Demant Klinker; Jasper Schipperijn; Jacqueline Kerr; Annette Kjær Ersbøll; Jens Troelsen
Journal:  Front Public Health       Date:  2014-03-11

9.  The environment can explain differences in adolescents' daily physical activity levels living in a deprived urban area: cross-sectional study using accelerometry, GPS, and focus groups.

Authors:  Helen Joy Moore; Catherine A Nixon; Amelia A Lake; Wayne Douthwaite; Claire L O'Malley; Claire L Pedley; Carolyn D Summerbell; Ashley C Routen
Journal:  J Phys Act Health       Date:  2014-04-11

10.  Validation of a previous day recall for measuring the location and purpose of active and sedentary behaviors compared to direct observation.

Authors:  Sarah Kozey Keadle; Kate Lyden; Amanda Hickey; Evan L Ray; Jay H Fowke; Patty S Freedson; Charles E Matthews
Journal:  Int J Behav Nutr Phys Act       Date:  2014-02-03       Impact factor: 6.457

View more
  26 in total

1.  The association of smartphone-based activity space measures with cognitive functioning and pain sickle cell disease.

Authors:  Charles R Jonassaint; Amit Birenboim; Dana Rae Jorgensen; Enrico M Novelli; Andrea L Rosso
Journal:  Br J Haematol       Date:  2017-07-17       Impact factor: 6.998

2.  Sensor Fusion to Infer Locations of Standing and Reaching Within the Home in Incomplete Spinal Cord Injury.

Authors:  Luca Lonini; Timothy Reissman; Jose M Ochoa; Chaithanya K Mummidisetty; Konrad Kording; Arun Jayaraman
Journal:  Am J Phys Med Rehabil       Date:  2017-10       Impact factor: 2.159

3.  Using Wearable Cameras to Investigate Health-Related Daily Life Experiences: A Literature Review of Precautions and Risks in Empirical Studies.

Authors:  Laurel E Meyer; Lauren Porter; Meghan E Reilly; Caroline Johnson; Salman Safir; Shelly F Greenfield; Benjamin C Silverman; James I Hudson; Kristin N Javaras
Journal:  Res Ethics       Date:  2021-10-30

4.  Unique Views on Obesity-Related Behaviors and Environments: Research Using Still and Video Images.

Authors:  Jordan A Carlson; J Aaron Hipp; Jacqueline Kerr; Todd S Horowitz; David Berrigan
Journal:  J Meas Phys Behav       Date:  2018-09

5.  Survalytics: An Open-Source Cloud-Integrated Experience Sampling, Survey, and Analytics and Metadata Collection Module for Android Operating System Apps.

Authors:  Vikas O'Reilly-Shah; Sean Mackey
Journal:  JMIR Mhealth Uhealth       Date:  2016-06-03       Impact factor: 4.773

6.  Using Bluetooth proximity sensing to determine where office workers spend time at work.

Authors:  Bronwyn K Clark; Elisabeth A Winkler; Charlotte L Brakenridge; Stewart G Trost; Genevieve N Healy
Journal:  PLoS One       Date:  2018-03-07       Impact factor: 3.240

Review 7.  Revealed Preference Methods for Studying Bicycle Route Choice-A Systematic Review.

Authors:  Ray Pritchard
Journal:  Int J Environ Res Public Health       Date:  2018-03-07       Impact factor: 3.390

8.  Virtual Fence System Based on IoT Paradigm to Prevent Occupational Accidents in the Construction Sector.

Authors:  María Del Carmen Rey-Merchán; Jesús M Gómez-de-Gabriel; Antonio López-Arquillos; Juan A Fernández-Madrigal
Journal:  Int J Environ Res Public Health       Date:  2021-06-25       Impact factor: 3.390

9.  Validity of a multi-context sitting questionnaire across demographically diverse population groups: AusDiab3.

Authors:  Bronwyn K Clark; Brigid M Lynch; Elisabeth Ah Winkler; Paul A Gardiner; Genevieve N Healy; David W Dunstan; Neville Owen
Journal:  Int J Behav Nutr Phys Act       Date:  2015-12-04       Impact factor: 6.457

10.  Brain Activation in Response to Personalized Behavioral and Physiological Feedback From Self-Monitoring Technology: Pilot Study.

Authors:  Maxine E Whelan; Paul S Morgan; Lauren B Sherar; Andrew P Kingsnorth; Daniele Magistro; Dale W Esliger
Journal:  J Med Internet Res       Date:  2017-11-08       Impact factor: 5.428

View more