Literature DB >> 23436621

Assessing internal contamination after the detonation of a radiological dispersion device using a 2x2-inch sodium iodide detector.

S Dewji1, N Hertel, A Ansari.   

Abstract

The detonation of a radiological dispersion device may result in a situation where individuals inhale radioactive materials and require rapid assessment of internal contamination. The feasibility of using a 2×2-inch sodium-iodide detector to determine the committed effective dose to an individual following acute inhalation of gamma-emitting radionuclides was investigated. Experimental configurations of point sources with a polymethyl methacrylate slab phantom were used to validate Monte Carlo simulations. The validated detector model was used to simulate the responses for four detector positions on six different anthropomorphic phantoms. The nuclides examined included (241)Am, (60)Co, (137)Cs, (131)I and (192)Ir. Biokinetic modelling was employed to determine the distributed activity in the body as a function of post-inhalation time. The simulation and biokinetic data were used to determine time-dependent count-rate values at optimal detector locations on the body for each radionuclide corresponding to a target committed effective dose (E50) value of 250 mSv.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23436621      PMCID: PMC5704924          DOI: 10.1093/rpd/nct014

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Use of Transportable Radiation Detection Instruments to Assess Internal Contamination from Intakes of Radionuclides Part II: Calibration Factors and ICAT Computer Program.

Authors:  Robert Anigstein; Richard H Olsher; Donald A Loomis; Armin Ansari
Journal:  Health Phys       Date:  2016-12       Impact factor: 1.316

2.  Use of Transportable Radiation Detection Instruments to Assess Internal Contamination From Intakes of Radionuclides Part I: Field Tests and Monte Carlo Simulations.

Authors:  Robert Anigstein; Michael C Erdman; Armin Ansari
Journal:  Health Phys       Date:  2016-06       Impact factor: 1.316

3.  Assessment of Residual Radioactivity by a Comprehensive Wireless, Wearable Device in Thyroid Cancer Patients Undergoing Radionuclide Therapy and Comparison With the Results of a Home Device: A Feasibility Study.

Authors:  R Gallicchio; D Scapicchio; A Nardelli; T Pellegrino; M Prisco; P Mainenti; C Sirignano; P Pedicini; G Storto
Journal:  IEEE J Transl Eng Health Med       Date:  2020-12-02       Impact factor: 3.316

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.