Determination of dosimetric characteristics of OptiSeed(TM) a plastic brachytherapy (103)Pd source.

Zhonglu Wang1, Nolan E Hertel.   

Abstract

A new (103)Pd plastic brachytherapy source, OptiSeed(TM) Model 1032P, is being introduced by International Brachytherapy sa (IBt). Measurements of the dose distributions about the source were performed using LiF thermoluminescent dosimeters (TLD-100) in Virtual Water(TM). MCNP5 calculations were performed to determine the dose distributions in Virtual Water(TM) and liquid water. The source dose rate constant, radial dose function, anisotropy function and anisotropy factor have been determined following the updated AAPM TG-43 recommendations. The measured dose rate constant in the Virtual Water(TM) phantom was determined to be 0.727+/-6.9% cGyh(-1)U(-1), and the computed value is 0.716+/-2.1% cGyh(-1)U(-1). The Monte-Carlo simulation yielded a dose rate constant of 0.665+/-2.1% cGyh(-1)U(-1) in water. The measured dose rate constant in water is 0.675+/-7.5% cGyh(-1)U(-1). It is determined by multiplying the dose rate constant measured in the Virtual Water(TM) phantom with the ratio of the value calculated in water to that in Virtual Water(TM). The average of the measured and calculated dose rate constant is 0.670+/-5.5% cGyh(-1)U(-1). The radial dose functions of the new source were measured for distances ranging from 1 to 7 cm in a Virtual Water(TM) phantom. The anisotropy functions in Virtual Water(TM) phantom were measured for distances of 2, 3, 5, and 7 cm. The Monte-Carlo computed radial dose functions, anisotropy functions, and anisotropy factors in both Virtual Water(TM) phantom and water are reported.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15964196     DOI: 10.1016/j.apradiso.2005.03.017

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  3 in total

1.  Dosimetric characterization of a new directional low-dose rate brachytherapy source.

Authors:  Manik Aima; Larry A DeWerd; Michael G Mitch; Clifford G Hammer; Wesley S Culberson
Journal:  Med Phys       Date:  2018-05-24       Impact factor: 4.071

2.  Photon energy spectrum emitted by a novel polymer-encapsulated 103Pd source and its effect on the dose rate constant.

Authors:  Sabrina Khan; Zhe Jay Chen; Ravinder Nath
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

3.  Assessing internal contamination after the detonation of a radiological dispersion device using a 2x2-inch sodium iodide detector.

Authors:  S Dewji; N Hertel; A Ansari
Journal:  Radiat Prot Dosimetry       Date:  2013-02-21       Impact factor: 0.972