Literature DB >> 23434538

A pilot trial of the iPad tablet computer as a portable device for visual acuity testing.

Zhao-tian Zhang1, Shao-chong Zhang, Xiong-gao Huang, Ling-yi Liang.   

Abstract

We evaluated the accuracy of an app for the iPad tablet computer (Eye Chart Pro) as a portable method of visual acuity (VA) testing. A total of 120 consecutive patients (240 eyes) underwent visual acuity test with an iPad 2 and a conventional light-box chart. The logMAR VA results from the iPad were significantly higher than those from the light-box (P < 0.001). Bland-Altman analysis revealed a mean difference (bias) of 0.02 logMAR units between the VA results from the iPad chart and the light-box chart, with 95% limits of agreement of -0.14 to 0.19. Two groups of patients were defined: in Group 1 there were 182 eyes with VA better than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 0.54 and by the light-box chart it was 0.52; there was no significant difference between them (P = 0.69). In Group 2 there were 58 eyes with VA equal to or worse than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 1.26 and was 1.10 by the light box; the result from the iPad was significantly lower (P < 0.001). The Eye Chart Pro app installed on the iPad is reliable for VA testing only when the Snellen VA is better than 0.1 (20/200).

Entities:  

Mesh:

Year:  2013        PMID: 23434538     DOI: 10.1177/1357633X12474964

Source DB:  PubMed          Journal:  J Telemed Telecare        ISSN: 1357-633X            Impact factor:   6.184


  17 in total

1.  Designing a new test for contrast sensitivity function measurement with iPad.

Authors:  Manuel Rodríguez-Vallejo; Laura Remón; Juan A Monsoriu; Walter D Furlan
Journal:  J Optom       Date:  2014-07-11

2.  Development and testing of an automated computer tablet-based method for self-testing of high and low contrast near visual acuity in ophthalmic patients.

Authors:  Tariq M Aslam; Neil R A Parry; Ian J Murray; Mahani Salleh; Caterina Dal Col; Naznin Mirza; Gabriela Czanner; Humza J Tahir
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-22       Impact factor: 3.117

3.  Visual acuity measured with a smartphone app is more accurate than Snellen testing by emergency department providers.

Authors:  Akhilesh S Pathipati; Edward H Wood; Carson K Lam; Christopher S Sáles; Darius M Moshfeghi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-03-01       Impact factor: 3.117

4.  Portable Perimetry Using Eye-Tracking on a Tablet Computer-A Feasibility Assessment.

Authors:  Pete R Jones; Nicholas D Smith; Wei Bi; David P Crabb
Journal:  Transl Vis Sci Technol       Date:  2019-02-05       Impact factor: 3.283

5.  A new visual acuity test on touchpad for vision screening in children.

Authors:  Elsa Di Foggia; Noémie Stoll; Hélène Meunier; Adam Rimelé; Pascal Ance; Pierre-Henri Moreau; Claude Speeg-Schatz; Arnaud Sauer
Journal:  Int J Ophthalmol       Date:  2020-09-18       Impact factor: 1.779

6.  Validation of Simplified Visual Acuity Testing Protocols in Amyotrophic Lateral Sclerosis.

Authors:  Lindsay C Boven; Qin Li Jiang; Heather E Moss
Journal:  Neuroophthalmology       Date:  2017-04-27

7.  Measurement of Retinal Sensitivity on Tablet Devices in Age-Related Macular Degeneration.

Authors:  Zhichao Wu; Robyn H Guymer; Chang J Jung; Jonathan K Goh; Lauren N Ayton; Chi D Luu; David J Lawson; Andrew Turpin; Allison M McKendrick
Journal:  Transl Vis Sci Technol       Date:  2015-06-30       Impact factor: 3.283

8.  An assessment of the iPad as a testing platform for distance visual acuity in adults.

Authors:  J M Black; R J Jacobs; G Phillips; L Chen; E Tan; A Tran; B Thompson
Journal:  BMJ Open       Date:  2013-06-20       Impact factor: 2.692

9.  Half of geriatric trauma patients have significant ocular disease: Findings of a novel trauma provider eye examination for vision screening.

Authors:  James M Bardes; Daniel J Grabo; James Donovan; Alexander Albuquerque; Kennith Conley Coleman; Sijin Wen; Alison Wilson; John Nguyen; Allison Bardes
Journal:  J Trauma Acute Care Surg       Date:  2021-07-01       Impact factor: 3.697

10.  Photometric Compliance of Tablet Screens and Retro-Illuminated Acuity Charts As Visual Acuity Measurement Devices.

Authors:  I A T Livingstone; C M Tarbert; M E Giardini; A Bastawrous; D Middleton; R Hamilton
Journal:  PLoS One       Date:  2016-03-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.