Literature DB >> 23428948

Comparison of image-guided radiotherapy technologies for prostate cancer.

Satya Das1, Tian Liu, Ashesh B Jani, Peter Rossi, Joseph Shelton, Zheng Shi, Mohammad K Khan.   

Abstract

Radiation oncology has seen a rapid increase in the use of image-guided radiotherapy technology (IGRT) for prostate cancer patients over the past decade. The increase in the use of IGRT is largely driven by the fact that these technologies have been approved by the Food and Drug Administration and are now readily reimbursed by many insurance companies. Prostate cancer patients undergoing intensity modulated radiotherapy (IMRT) now have access to a wide variety of IGRTs that can cost anywhere from $500,000 or more in upfront costs, and can add anywhere from 10 to 15 thousand dollars to a course of IMRT. Some of the IGRT options include daily cone beam computed tomography, ultrasound, orthogonal x-ray units using implanted fiducial markers, implanted radiofrequency markers with the ability to localize and track prostate motion during radiotherapy (Calypso 4D), and cine magnetic resonance imaging. Although these technologies add to the cost of IMRT, there is little direct comparative effectiveness data to help patients, physicians, and policy makers decide if one technology is better than another. In our critical review, the first of its kind, we summarize the advantages, disadvantages, and the limitations of each technology. We also provide an overview of existing literature as it pertains to the comparison of existing IGRTs. Lastly, we provide insights about the need for future outcomes research that may have a significant impact on health policies as it comes to reimbursement in the modern era.

Entities:  

Mesh:

Year:  2014        PMID: 23428948     DOI: 10.1097/COC.0b013e31827e4eb9

Source DB:  PubMed          Journal:  Am J Clin Oncol        ISSN: 0277-3732            Impact factor:   2.339


  19 in total

Review 1.  Pictorial review. Magnetic resonance for radiotherapy management and treatment planning in prostatic carcinoma.

Authors:  Christopher Lim; Shawn C Malone; Leonard Avruch; Rodney H Breau; Trevor A Flood; Megan Lim; Christopher Morash; Jeff S Quon; Cynthia Walsh; Nicola Schieda
Journal:  Br J Radiol       Date:  2015-08-17       Impact factor: 3.039

2.  [Comparison of combined IMRT and IGRT with conventional 3D-CRT in the irradiation of prostate cancer : Studying the advantages strongly depends on the conditions].

Authors:  Norbert Hodapp
Journal:  Strahlenther Onkol       Date:  2017-05       Impact factor: 3.621

Review 3.  Effectiveness of rectal displacement devices in managing prostate motion: a systematic review.

Authors:  Mahdieh Afkhami Ardekani; Hamed Ghaffari; Mahmoud Navaser; Seyed Hamid Zoljalali Moghaddam; Soheila Refahi
Journal:  Strahlenther Onkol       Date:  2020-05-22       Impact factor: 3.621

4.  Toxicity reduction required for MRI-guided radiotherapy to be cost-effective in the treatment of localized prostate cancer.

Authors:  Leif-Erik D Schumacher; Alan Dal Pra; Sarah E Hoffe; Eric A Mellon
Journal:  Br J Radiol       Date:  2020-08-12       Impact factor: 3.039

5.  A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy.

Authors:  Malcolm D Mattes; Jennifer C Lee; Sara Elnaiem; Adel Guirguis; N C Ikoro; Hani Ashamalla
Journal:  Radiat Oncol J       Date:  2014-03-27

Review 6.  Image-guided radiation therapy in lymphoma management.

Authors:  Tony Eng; Chul S Ha
Journal:  Radiat Oncol J       Date:  2015-09-30

7.  Comparison between electromagnetic transponders and radiographic imaging for prostate localization: A pelvic phantom study with rotations and translations.

Authors:  Daniel G Hamilton; Dean P McKenzie; Anne E Perkins
Journal:  J Appl Clin Med Phys       Date:  2017-07-12       Impact factor: 2.102

8.  Using daily diagnostic quality images to validate planning margins for prostate interfractional variations

Authors:  Wen Li; Andrew Vassil; Andrew Godley; Lama Muhieddine Mossolly; Qingyang Shang; Ping Xia
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

Review 9.  ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II.

Authors:  Nicholas G Zaorsky; Timothy N Showalter; Gary A Ezzell; Paul L Nguyen; Dean G Assimos; Anthony V D'Amico; Alexander R Gottschalk; Gary S Gustafson; Sameer R Keole; Stanley L Liauw; Shane Lloyd; Patrick W McLaughlin; Benjamin Movsas; Bradley R Prestidge; Al V Taira; Neha Vapiwala; Brian J Davis
Journal:  Adv Radiat Oncol       Date:  2017-03-20

10.  Intrafractional Tracking Accuracy of a Transperineal Ultrasound Image Guidance System for Prostate Radiotherapy.

Authors:  Dimitre H Hristov; Tiffany Phillips; Amy S Yu; Mohammad Najafi
Journal:  Technol Cancer Res Treat       Date:  2017-09-21
View more