Literature DB >> 23419572

A unique model for ultrasound assessment of optic nerve sheath diameter.

Frederick A Zeiler1, Bertram Unger, Andreas H Kramer, Andrew W Kirkpatrick, Lawrence M Gillman.   

Abstract

BACKGROUND: Ultrasonic assessment of optic nerve sheath diameter (ONSD) as a non-invasive measure of intracranial pressure (ICP) has been evaluated in the literature as a potential valid technique for rapid ICP estimation in the absence of invasive intracranial monitoring. The technique can be challenging to perform and little literature exists surrounding intra-operator variability.
OBJECTIVES: In this study we describe the creation of a novel model of ONSD to be utilized in ultrasound training of this technique. We demonstrate the realistic ultrasonographic images created utilizing this novel model.
METHODS: We designed ocular models composed of gelatin spheres and variable three dimensional printed cylinders, which simulate the globe of the eye and variable ONSD's respectively. These models were suspended in a gelatin background and ultrasound of the ONSD was conducted using standard techniques described in the literature.
RESULTS: This model produces clear and accurate representation of ONSD that closely mimics in vivo images. It is affordable and easy to produce in large quantities, portending its use in an educational environment.
CONCLUSIONS: Utilizing the standard linear array ultrasound probe for ONSD measurements in our model provided realistic images comparable to in vivo. This provides an affordable and exciting means to test intra- and inter- operator variability in a standardized environment. Knowing this, we can further apply this novel model of ONSD to ultrasound teaching and training courses with confidence in its ability and the technique's ability to produce consistent results.

Mesh:

Substances:

Year:  2013        PMID: 23419572     DOI: 10.1017/s0317167100013779

Source DB:  PubMed          Journal:  Can J Neurol Sci        ISSN: 0317-1671            Impact factor:   2.104


  11 in total

Review 1.  Use of three-dimensional printing for simulation in ultrasound education: a scoping review.

Authors:  Patrick Gallagher; Ryan Smith; Gillian Sheppard
Journal:  BMJ Simul Technol Enhanc Learn       Date:  2020-09-04

2.  Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model.

Authors:  Garrett G R J Johnson; Frederick A Zeiler; Bertram Unger; Gregory Hansen; Dimitrios Karakitsos; Lawrence M Gillman
Journal:  Crit Ultrasound J       Date:  2016-11-10

3.  Optic Nerve Sheath Diameter Ultrasound Evaluation in Intensive Care Unit: Possible Role and Clinical Aspects in Neurological Critical Patients' Daily Monitoring.

Authors:  M Toscano; G Spadetta; P Pulitano; M Rocco; V Di Piero; O Mecarelli; E Vicenzini
Journal:  Biomed Res Int       Date:  2017-03-21       Impact factor: 3.411

4.  New Optic Nerve Sonography Quality Criteria in the Diagnostic Evaluation of Traumatic Brain Injury.

Authors:  Ibrahim Soliman; Garrett G R J Johnson; Lawrence M Gillman; Frederick A Zeiler; Fahad Faqihi; Waleed Tharwat Aletreby; Abdullah Balhamar; Nasir Nasim Mahmood; Shahzad Ahmad Mumtaz; Abdulrahman Alharthy; Christos Lazaridis; Dimitrios Karakitsos
Journal:  Crit Care Res Pract       Date:  2018-04-30

5.  Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool.

Authors:  David L Murphy; Stephanie H Oberfoell; Stacy A Trent; Andrew J French; Daniel J Kim; David B Richards
Journal:  J Med Ultrasound       Date:  2017-03-08

6.  Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls.

Authors:  Mary E Sterrett; Brittany Austin; Ryan M Barnes; Eugene Y Chang
Journal:  BMC Pregnancy Childbirth       Date:  2022-03-19       Impact factor: 3.007

Review 7.  Simulation in Neurocritical Care: Past, Present, and Future.

Authors:  Nicholas A Morris; Barry M Czeisler; Aarti Sarwal
Journal:  Neurocrit Care       Date:  2019-06       Impact factor: 3.210

8.  A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement.

Authors:  Frederick A Zeiler; Markus T Ziesmann; Patrick Goeres; Bertram Unger; Jason Park; Dimitrios Karakitsos; Michael Blaivas; Ashley Vergis; Lawrence M Gillman
Journal:  Crit Ultrasound J       Date:  2016-08-08

9.  From medical imaging data to 3D printed anatomical models.

Authors:  Thore M Bücking; Emma R Hill; James L Robertson; Efthymios Maneas; Andrew A Plumb; Daniil I Nikitichev
Journal:  PLoS One       Date:  2017-05-31       Impact factor: 3.240

10.  Creation of an optic nerve sheath diameter ultrasound model for NeuroICU education.

Authors:  Heidi M Felix; Kristin A Rosenbush; Amy M Lannen; Robert A Pooley; Jason L Siegel; Benjamin L Brown; Melissa L McMullan; Christina I Collins; William D Freeman
Journal:  Mil Med Res       Date:  2020-09-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.