Literature DB >> 23417855

LeGoo polymer injection into hydatid cyst would eliminate intraoperative spillage of scolices.

Fadhil Al-Amran1, Hayder M Abdulnabi.   

Abstract

BACKGROUND: Hydatid disease is caused by the tapeworm Echinococcus granulosus or Echinococcus multilocularis or Echinococcus Vogeli. It is the most severe helminthic zoonosis, with a major medical, social, and economic burden in endemic areas such as the Mediterranean region, South America, Australia, Turkey, New Zealand, Alaska, Canada, and the Middle East. The cornerstone in the management of hydatid cysts is surgery, and its recurrence is due mainly to the spillage of hydatid scolices rich fluid into the surrounding tissues. AIM: In this study, we test a polymer benefit in intraoperative scolices spillage prevention, this polymer is called LeGoo.
METHODS: The LeGoo polymer was used here in vivo animal's hydatid cysts and in vitro hydatid cysts excised from human beings. RESULT: Microscopic examination of the aspirated fluid from human being and sheep hydatid cysts before LeGoo injection showed numerous alive scolices. All sheep lung hydatid cysts with LeGoo injection transformed into a solid gelatinous mass, microscopic examination of the content swabs showed no scolices. LeGoo polymer injection into human hydatid cysts in vitro changed them into a solid gelatinous mass that can be mobilized easily with negative swabs for scolices.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23417855     DOI: 10.1007/s11748-013-0217-5

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  11 in total

1.  Thermosensitive polymer use for shunt sealing in off-pump coronary artery bypass.

Authors:  Marco Agostini; Francesco Lemut; Vincenzo Di Gregorio; Claudio Grossi
Journal:  Innovations (Phila)       Date:  2010-03

2.  Temporary internal thoracic artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction.

Authors:  Marie-Claude Aubin; Olivier Bouchot; Michel Carrier; William E Cohn; Louis P Perrault
Journal:  J Thorac Cardiovasc Surg       Date:  2006-09       Impact factor: 5.209

3.  Effects of purified poloxamer 407 gel on vascular occlusion and the coronary endothelium.

Authors:  Munir Boodhwani; Jun Feng; Shigetoshi Mieno; Basel Ramlawi; Neel Sodha; Richard Clements; Frank W Sellke
Journal:  Eur J Cardiothorac Surg       Date:  2006-04-12       Impact factor: 4.191

4.  Safety and efficacy of a novel gel for vascular occlusion in off-pump surgery.

Authors:  Munir Boodhwani; William E Cohn; Jun Feng; Basel Ramlawi; Shigetoshi Mieno; Alexander Schwarz; Frank W Sellke
Journal:  Ann Thorac Surg       Date:  2005-12       Impact factor: 4.330

5.  Use of the Purified Poloxamer 407 for Temporary Coronary Occlusion in Off-Pump CABG Does Not Cause Myocardial Injury.

Authors:  Arnaud Mommerot; Marie-Claude Aubin; Michel Carrier; William E Cohn; Louis P Perrault
Journal:  Innovations (Phila)       Date:  2007-07

6.  Surgical treatment of hydatid cysts of the lung: analysis of 405 patients.

Authors:  O K Salih; M S Topcuoğlu; S K Celik; T Ulus; A Tokcan
Journal:  Can J Surg       Date:  1998-04       Impact factor: 2.089

7.  Randomized clinical trial comparing a thermosensitive polymer (LeGoo) with conventional vessel loops for temporary coronary artery occlusion during off-pump coronary artery bypass surgery.

Authors:  Gerhard Wimmer-Greinecker; Olivier Bouchot; Jean P Verhoye; Louis P Perrault; Jochen Börgermann; Anno Diegeler; Leen Van Garsse; Ardawan J Rastan
Journal:  Ann Thorac Surg       Date:  2011-12       Impact factor: 4.330

8.  Temporary coronary artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction in epicardial coronary arteries.

Authors:  Olivier Bouchot; Marie-Claude Aubin; Michel Carrier; William E Cohn; Louis P Perrault
Journal:  J Thorac Cardiovasc Surg       Date:  2006-11       Impact factor: 5.209

9.  Facilitated anastomosis using a reverse thermo-sensitive polymer for temporary coronary occlusion in off-pump minimally invasive direct coronary artery bypass surgery.

Authors:  Ardawan Julian Rastan; Thilo Noack; Sreekumar Subramanian; Alpen Nacar; David Holzhey; Volkmar Falk; Friedrich Wilhelm Mohr
Journal:  Interact Cardiovasc Thorac Surg       Date:  2010-08-25

10.  Clinical experience with a novel thermosensitive temporary coronary artery occluder (LeGoo).

Authors:  Olivier Bouchot; Robert L Berger; Jean Pierre Berne; François Brunotte; Roger Brenot
Journal:  Ann Thorac Surg       Date:  2010-06       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.