Literature DB >> 23412749

In vivo diffusion-weighted MRI using perfluorinated gases: ADC comparison between healthy and elastase-treated rat lungs.

L Carrero-González1, T Kaulisch, D Stiller.   

Abstract

PURPOSE: MRI with perfluorinated gases has been shown as an alternative to hyperpolarized gases to image both microstructure and gas diffusivity in the lung. The aim of this study was to measure diffusion restriction of C2 F6 in rat lungs and to compare the different levels of restriction between healthy and emphysematous tissue.
METHODS: For this purpose, two groups of rats-healthy and mono-lobar elastase-induced animals-were measured. While being ventilated with a mixture of C2 F6 and oxygen four diffusion weighted 19F-images where acquired for each animal and corresponding ADC-maps were calculated.
RESULTS: No significant apparent diffusion coefficient (ADC) differences were found between healthy lungs; however, the elastase treated lungs showed a significant increase in ADC.
CONCLUSION: These results demonstrate that ADC measurements with C2 F6 are sensitive to the microstructure of rat lungs showing that the diffusion of this gas is limited to different levels in healthy and in emphysematous tissue.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  ADC; C2F6; elastase; emphysema; in vivo small animals imaging

Mesh:

Substances:

Year:  2013        PMID: 23412749     DOI: 10.1002/mrm.24627

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  Functional imaging of the lungs with gas agents.

Authors:  Stanley J Kruger; Scott K Nagle; Marcus J Couch; Yoshiharu Ohno; Mitchell Albert; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

Review 2.  Overview of MRI for pulmonary functional imaging.

Authors:  Yoshiharu Ohno; Satomu Hanamatsu; Yuki Obama; Takahiro Ueda; Hirotaka Ikeda; Hidekazu Hattori; Kazuhiro Murayama; Hiroshi Toyama
Journal:  Br J Radiol       Date:  2021-02-02       Impact factor: 3.629

Review 3.  Fluorine-19 MRI Contrast Agents for Cell Tracking and Lung Imaging.

Authors:  Matthew S Fox; Jeffrey M Gaudet; Paula J Foster
Journal:  Magn Reson Insights       Date:  2016-03-22

4.  Evaluation of fluorine-19 magnetic resonance imaging of the lungs using octafluorocyclobutane in a rat model.

Authors:  Yurii Shepelytskyi; Tao Li; Vira Grynko; Camryn Newman; Francis T Hane; Mitchell S Albert
Journal:  Magn Reson Med       Date:  2020-08-12       Impact factor: 4.668

  4 in total