Literature DB >> 23412404

Short-segment pedicle instrumentation with transpedicular bone grafting for nonunion of osteoporotic vertebral fractures involving the posterior edge.

Dapeng Li1, Yonghui Huang, Huilin Yang, Taicun Sun, Yan Wu, Xuefeng Li, Liang Chen.   

Abstract

Most osteoporotic vertebral fractures (OVFs) can be treated successfully with conservative methods. In about 10% of patients, nonunion develops and warrants surgical management with minimally invasive procedures such as vertebroplasty and kyphoplasty. Nevertheless, for patients with nonunion fractures that involve the posterior vertebral body wall, vertebroplasty and kyphoplasty are relatively contraindicated due to the risk of extravertebral polymethylmethacrylate cement leakage through vertebral fracture cracks. To this end, we developed a method for pedicle screw fixation combined with transpedicular bone grafting for such a condition. Briefly, after posterior pedicle screw fixation and reduction in the affected vertebra, the demineralized bone matrix was inserted into the vertebral body via a 'bone grafting funnel' created through the pedicle of the affected vertebra. The current retrospective study analysed the safety and efficacy of this approach. A total of 12 patients who fulfilled the criteria were treated with this procedure. Visual analogue scale scores for back pain and anterior vertebral heights were recorded. At 3-month follow-up, pain was significantly relieved compared with presurgery and the anterior vertebral heights were successfully restored and maintained. In conclusion, short-segment pedicle instrumentation combined with transpedicular bone grafting is a useful alternative in the treatment of nonunion of OVFs with loss of posterior edge integrity.

Entities:  

Mesh:

Year:  2011        PMID: 23412404     DOI: 10.1007/s00590-011-0928-1

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  22 in total

1.  The linear intravertebral vacuum: a sign of benign vertebral collapse.

Authors:  S Bhalla; W R Reinus
Journal:  AJR Am J Roentgenol       Date:  1998-06       Impact factor: 3.959

2.  The intravertebral vacuum phenomenon ("vertebral osteonecrosis"). Migration of intradiscal gas in a fractured vertebral body?

Authors:  P Lafforgue; C Chagnaud; V Daumen-Legré; L Daver; M Kasbarian; P C Acquaviva
Journal:  Spine (Phila Pa 1976)       Date:  1997-08-15       Impact factor: 3.468

3.  Posterior spinal shortening for paraplegia after vertebral collapse caused by osteoporosis.

Authors:  K Saita; Y Hoshino; I Kikkawa; H Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2000-11-01       Impact factor: 3.468

4.  Changes in vertebral wedging rate between supine and standing position and its association with back pain: a prospective study in patients with osteoporotic vertebral compression fractures.

Authors:  Tomoaki Toyone; Tomoaki Toyone; Tadashi Tanaka; Yuichi Wada; Koya Kamikawa; Masaaki Ito; Kenji Kimura; Takeshi Yamasita; Satoshi Matsushita; Ryutaro Shiboi; Daisuke Kato; Ryutaku Kaneyama; Makoto Otsuka
Journal:  Spine (Phila Pa 1976)       Date:  2006-12-01       Impact factor: 3.468

5.  Kyphoplasty for salvage of a failed vertebroplasty in osteoporotic vertebral compression fractures: case report and surgical technique.

Authors:  S Tim Yoon; Abid A Qureshi; John G Heller; John C Nordt
Journal:  J Spinal Disord Tech       Date:  2005-02

6.  Vertebral pseudarthrosis in the osteoporotic spine.

Authors:  K Hasegawa; T Homma; S Uchiyama; H Takahashi
Journal:  Spine (Phila Pa 1976)       Date:  1998-10-15       Impact factor: 3.468

7.  A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures.

Authors:  Rachelle Buchbinder; Richard H Osborne; Peter R Ebeling; John D Wark; Peter Mitchell; Chris Wriedt; Stephen Graves; Margaret P Staples; Bridie Murphy
Journal:  N Engl J Med       Date:  2009-08-06       Impact factor: 91.245

8.  Intravertebral vacuum phenomenon in osteoporotic compression fracture: report of 67 cases with quantitative evaluation of intravertebral instability.

Authors:  Dong-Yun Kim; Sang-Ho Lee; Jee Soo Jang; Sang Ki Chung; Ho-Yeon Lee
Journal:  J Neurosurg       Date:  2004-01       Impact factor: 5.115

Review 9.  Osteoporotic vertebral fractures and collapse with intravertebral vacuum sign (Kümmel's disease).

Authors:  Ioannis P Pappou; Elias C Papadopoulos; Andrew N Swanson; Frank P Cammisa; Federico P Girardi
Journal:  Orthopedics       Date:  2008-01       Impact factor: 1.390

10.  Mortality risk associated with low-trauma osteoporotic fracture and subsequent fracture in men and women.

Authors:  Dana Bliuc; Nguyen D Nguyen; Vivienne E Milch; Tuan V Nguyen; John A Eisman; Jacqueline R Center
Journal:  JAMA       Date:  2009-02-04       Impact factor: 56.272

View more
  2 in total

1.  Jack vertebral dilator kyphoplasty for treatment of osteoporotic vertebral compression fractures.

Authors:  Dapeng Li; Yonghui Huang; Huilin Yang; Qi Chen; Taicun Sun; Yan Wu; Xuefeng Li
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-11

2.  Bone Cement-Augmented Short-Segment Pedicle Screw Fixation for Kümmell Disease with Spinal Canal Stenosis.

Authors:  Yan-Sheng Huang; Chao-Yuan Ge; Hang Feng; Hai-Ping Zhang; Xing-Bang Niu; Shao-Yan Shi; Zi-Qi Zhu; Ding-Jun Hao
Journal:  Med Sci Monit       Date:  2018-02-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.