Use of dried plasma spots for the quantification of iothalamate in clinical studies.

Andrew S Hagan1, David R Jones, Rajiv Agarwal.   

Abstract

BACKGROUND AND OBJECTIVES: Although iothalamate clearances have been widely used to measure GFR, the need for transportation of plasma samples under refrigerated conditions obviates its use in resource-poor situations. Spots of blood or plasma dried on filter paper may provide a solution. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Using a validated HPLC technique, iothalamate in dried blood spots of different hematocrits was measured. GFR was measured over 5 hours in 10 subjects with CKD using dried plasma spots and standard methods.
RESULTS: Lower hematocrit produced greater area of blood spreading and lowered the recovery of iothalamate from dried blood spots. However, the relationship between iothalamate concentrations in dried plasma spots and plasma showed a regression slope of 0.95 (95% confidence interval=0.92-0.98, P<0.001). Bland-Altman plot of paired sample points (n=116) showed a bias of -4 μg/ml and limits of agreement of -38 to +30 μg/ml. The relationship between GFRs using dried plasma spots and plasma methods also showed an excellent relationship (slope of 0.95, 95% confidence interval=0.82-1.17). Bland-Altman plot of paired GFRs showed a bias of 2 ml/min, with limits of agreement of -6 to +10 ml/min. Precision was generally between 5% and 10%, and accuracy was within 5%.
CONCLUSIONS: Although dried blood spots are unsuitable for studies among those patients with very low hematocrit, dried plasma spots correct for this limitation, and this small pilot study shows that it is a reasonably reliable method for quantifying iothalamate and subsequently, determining GFR.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23411426      PMCID: PMC3675857          DOI: 10.2215/CJN.10471012

Source DB:  PubMed          Journal:  Clin J Am Soc Nephrol        ISSN: 1555-9041            Impact factor:   8.237


  15 in total

1.  Bioanalytical method validation--a revisit with a decade of progress.

Authors:  V P Shah; K K Midha; J W Findlay; H M Hill; J D Hulse; I J McGilveray; G McKay; K J Miller; R N Patnaik; M L Powell; A Tonelli; C T Viswanathan; A Yacobi
Journal:  Pharm Res       Date:  2000-12       Impact factor: 4.200

Review 2.  Use of filter paper for the collection and analysis of human whole blood specimens.

Authors:  J V Mei; J R Alexander; B W Adam; W H Hannon
Journal:  J Nutr       Date:  2001-05       Impact factor: 4.798

3.  THE EXCRETION OF INULIN, XYLOSE AND UREA BY NORMAL AND PHLORIZINIZED MAN.

Authors:  J A Shannon; H W Smith
Journal:  J Clin Invest       Date:  1935-07       Impact factor: 14.808

Review 4.  Estimating equations for glomerular filtration rate in the era of creatinine standardization: a systematic review.

Authors:  Amy Earley; Dana Miskulin; Edmund J Lamb; Andrew S Levey; Katrin Uhlig
Journal:  Ann Intern Med       Date:  2012-02-06       Impact factor: 25.391

5.  Dried blood spots as a sample collection technique for the determination of pharmacokinetics in clinical studies: considerations for the validation of a quantitative bioanalytical method.

Authors:  Neil Spooner; Rakesh Lad; Matt Barfield
Journal:  Anal Chem       Date:  2009-02-15       Impact factor: 6.986

6.  Comparison of iothalamate clearance methods for measuring GFR.

Authors:  T C Dowling; R F Frye; D S Fraley; G R Matzke
Journal:  Pharmacotherapy       Date:  1999-08       Impact factor: 4.705

7.  Glomerular filtration rate measurement by "single-shot" injection of inulin.

Authors:  K W Florijn; J N Barendregt; E G Lentjes; W van Dam; W Prodjosudjadi; J L van Saase; L A van Es; P C Chang
Journal:  Kidney Int       Date:  1994-07       Impact factor: 10.612

8.  Analysis of filter-paper-absorbed, finger-stick blood samples for chloroquine and its major metabolite using high-performance liquid chromatography with fluorescence detection.

Authors:  L C Patchen; D L Mount; I K Schwartz; F C Churchill
Journal:  J Chromatogr       Date:  1983-11-11

9.  Neonatal cytokines and coagulation factors in children with cerebral palsy.

Authors:  K B Nelson; J M Dambrosia; J K Grether; T M Phillips
Journal:  Ann Neurol       Date:  1998-10       Impact factor: 10.422

10.  Assessment of iothalamate plasma clearance: duration of study affects quality of GFR.

Authors:  Rajiv Agarwal; Jennifer E Bills; Paulos M Yigazu; Terri Abraham; Andinet B Gizaw; Robert P Light; Dagim M Bekele; Getachew G Tegegne
Journal:  Clin J Am Soc Nephrol       Date:  2008-11-12       Impact factor: 8.237

View more
  3 in total

Review 1.  Measured GFR in Routine Clinical Practice-The Promise of Dried Blood Spots.

Authors:  Petter Bjornstad; Amy B Karger; David M Maahs
Journal:  Adv Chronic Kidney Dis       Date:  2018-01       Impact factor: 3.620

2.  Quantification of Warfarin in Dried Rat Plasma Spots by High-Performance Liquid Chromatography with Tandem Mass Spectrometry.

Authors:  Alexander Chernonosov
Journal:  J Pharm (Cairo)       Date:  2016-12-12

3.  HPLC estimation of iothalamate to measure glomerular filtration rate in humans.

Authors:  Iltaf Shah; James Barker; Declan P Naughton; Stephen J Barton; Syed Salman Ashraf
Journal:  Chem Cent J       Date:  2016-12-12       Impact factor: 4.215

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.