Literature DB >> 10453965

Comparison of iothalamate clearance methods for measuring GFR.

T C Dowling1, R F Frye, D S Fraley, G R Matzke.   

Abstract

STUDY
OBJECTIVE: To evaluate the bias and precision of three methods of measuring glomerular filtration rate (GFR) relative to a standard method.
DESIGN: Prospective, outpatient study.
SETTING: University-affiliated general clinical research center. PATIENTS: Twenty-six patients with various degrees of renal function (GFR range 25-151 ml/min/1.73 m2).
INTERVENTIONS: Each patient received iothalamate twice during the study visit, first as a bolus injection and then as a priming dose followed by a constant-rate infusion for 2.5 hours.
MEASUREMENTS AND MAIN RESULTS: Plasma (ClpIVB) and renal clearances (ClrIVB) after bolus injection and plasma clearance during constant-rate infusion (ClpINF) were compared with standard renal clearance during constant-rate infusion (ClrINF). All three measures were highly correlated with ClrINF (r>0.90, p<0.001). The mean ClrIVB was not significantly different from ClrINF (106.3+/-30.4 vs 104.2+/-28.5 ml/min/1.73 m2) and provided a precise (8.8%, 95% CI 6.5-11.1%) and unbiased measure of GFR. Both ClpIVB and ClpINF were positively biased; values exceeded ClrINF by 11.8+/-11.1 (p=0.0001) and 10.5+/-12.5 ml/min/1.73 m2 (p=0.0003), respectively. Use of a nonrenal correction factor of 9.8 and 10.5 ml/min/1.73 m2 for infusion and bolus plasma clearance values, respectively, eliminated bias and improved the precision of these methods.
CONCLUSIONS: Iothalamate renal clearance after bolus injection is a simple, accurate, and precise measurement of GFR and may be a useful alternative to the standard infusion method in clinical investigations. The corrected plasma clearance provides a simple index of GFR for clinical practice.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10453965     DOI: 10.1592/phco.19.11.943.31576

Source DB:  PubMed          Journal:  Pharmacotherapy        ISSN: 0277-0008            Impact factor:   4.705


  4 in total

1.  Use of dried plasma spots for the quantification of iothalamate in clinical studies.

Authors:  Andrew S Hagan; David R Jones; Rajiv Agarwal
Journal:  Clin J Am Soc Nephrol       Date:  2013-02-14       Impact factor: 8.237

2.  Assessment of iothalamate plasma clearance: duration of study affects quality of GFR.

Authors:  Rajiv Agarwal; Jennifer E Bills; Paulos M Yigazu; Terri Abraham; Andinet B Gizaw; Robert P Light; Dagim M Bekele; Getachew G Tegegne
Journal:  Clin J Am Soc Nephrol       Date:  2008-11-12       Impact factor: 8.237

3.  The Impact of Different Induction Immunosuppressive Therapy on Long-Term Kidney Transplant Function When Measured by Iothalamate Clearance.

Authors:  Tambi Jarmi; Samir Khouzam; Nitika Shekhar; Meray Hosni; Launia White; David O Hodge; Martin L Mai; Hani M Wadei
Journal:  J Clin Med Res       Date:  2020-12-18

4.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.