Literature DB >> 23403908

Color-matched and fluorescence-labeled esophagus phantom and its applications.

Chenying Yang1, Vivian Hou, Leonard Y Nelson, Eric J Seibel.   

Abstract

We developed a stable, reproducible three-dimensional optical phantom for the evaluation of a wide-field endoscopic molecular imaging system. This phantom mimicked a human esophagus structure with flexibility to demonstrate body movements. At the same time, realistic visual appearance and diffuse spectral reflectance properties of the tissue were simulated by a color matching methodology. A photostable dye-in-polymer technology was applied to represent biomarker probed "hot-spot" locations. Furthermore, fluorescent target quantification of the phantom was demonstrated using a 1.2 mm ultrathin scanning fiber endoscope with concurrent fluorescence-reflectance imaging.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23403908      PMCID: PMC3569733          DOI: 10.1117/1.JBO.18.2.026020

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  51 in total

1.  Molecular imaging using fluorescent lectins permits rapid endoscopic identification of dysplasia in Barrett's esophagus.

Authors:  Elizabeth L Bird-Lieberman; André A Neves; Pierre Lao-Sirieix; Maria O'Donovan; Marco Novelli; Laurence B Lovat; William S Eng; Lara K Mahal; Kevin M Brindle; Rebecca C Fitzgerald
Journal:  Nat Med       Date:  2012-01-15       Impact factor: 53.440

2.  Tethered capsule endoscopy, a low-cost and high-performance alternative technology for the screening of esophageal cancer and Barrett's esophagus.

Authors:  Eric J Seibel; Robert E Carroll; Jason A Dominitz; Richard S Johnston; C David Melville; Cameron M Lee; Steven M Seitz; Michael B Kimmey
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

3.  Analysis of changes in reflectance measurements on biological tissues subjected to different probe pressures.

Authors:  Roberto Reif; Mark S Amorosino; Katherine W Calabro; Ousama A'Amar; Satish K Singh; Irving J Bigio
Journal:  J Biomed Opt       Date:  2008 Jan-Feb       Impact factor: 3.170

4.  Homogenized tissue phantoms for quantitative evaluation of subsurface fluorescence contrast.

Authors:  Mathieu Roy; Anthony Kim; Farhan Dadani; Brian C Wilson
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

Review 5.  Novel image-enhanced endoscopy with i-scan technology.

Authors:  Shinya Kodashima; Mitsuhiro Fujishiro
Journal:  World J Gastroenterol       Date:  2010-03-07       Impact factor: 5.742

6.  Narrow-band imaging versus I-Scan for the real-time histological prediction of diminutive colonic polyps: a prospective comparative study by using the simple unified endoscopic classification.

Authors:  Chang Kyun Lee; Suck-Ho Lee; Young Hwangbo
Journal:  Gastrointest Endosc       Date:  2011-07-18       Impact factor: 9.427

7.  Risk of oesophageal cancer in Barrett's oesophagus and gastro-oesophageal reflux.

Authors:  M Solaymani-Dodaran; R F A Logan; J West; T Card; C Coupland
Journal:  Gut       Date:  2004-08       Impact factor: 23.059

Review 8.  Spectroscopy and fluorescence in esophageal diseases.

Authors:  Ralph S Dacosta; Brian C Wilson; Norman E Marcon
Journal:  Best Pract Res Clin Gastroenterol       Date:  2006-02       Impact factor: 3.043

9.  Exogenous Molecular Probes for Targeted Imaging in Cancer: Focus on Multi-modal Imaging.

Authors:  Bishnu P Joshi; Thomas D Wang
Journal:  Cancers (Basel)       Date:  2010-06-11       Impact factor: 6.639

10.  Three-dimensional phantoms for curvature correction in spatial frequency domain imaging.

Authors:  Thu T A Nguyen; Hanh N D Le; Minh Vo; Zhaoyang Wang; Long Luu; Jessica C Ramella-Roman
Journal:  Biomed Opt Express       Date:  2012-05-03       Impact factor: 3.732

View more
  8 in total

1.  Mitigating fluorescence spectral overlap in wide-field endoscopic imaging.

Authors:  Chenying Yang; Vivian Hou; Leonard Y Nelson; Eric J Seibel
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

2.  Accurate three-dimensional virtual reconstruction of surgical field using calibrated trajectories of an image-guided medical robot.

Authors:  Yuanzheng Gong; Danying Hu; Blake Hannaford; Eric J Seibel
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-02

3.  Target-to-background enhancement in multispectral endoscopy with background autofluorescence mitigation for quantitative molecular imaging.

Authors:  Chenying Yang; Vivian W Hou; Emily J Girard; Leonard Y Nelson; Eric J Seibel
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

4.  Multimodal 3D cancer-mimicking optical phantom.

Authors:  Gennifer T Smith; Kristen L Lurie; Dimitar V Zlatev; Joseph C Liao; Audrey K Ellerbee Bowden
Journal:  Biomed Opt Express       Date:  2016-01-25       Impact factor: 3.732

5.  Multimodal laser-based angioscopy for structural, chemical and biological imaging of atherosclerosis.

Authors:  Luis E Savastano; Quan Zhou; Arlene Smith; Karla Vega; Carlos Murga-Zamalloa; David Gordon; Jon McHugh; Lili Zhao; Michael Wang; Aditya Pandey; B Gregory Thompson; Jie Xu; Jifeng Zhang; Y Eugene Chen; Eric J Seibel; Thomas D Wang
Journal:  Nat Biomed Eng       Date:  2017-02-10       Impact factor: 25.671

6.  Toward real-time quantification of fluorescence molecular probes using target/background ratio for guiding biopsy and endoscopic therapy of esophageal neoplasia.

Authors:  Yang Jiang; Yuanzheng Gong; Joel H Rubenstein; Thomas D Wang; Eric J Seibel
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-24

7.  Mapping surgical fields by moving a laser-scanning multimodal scope attached to a robot arm.

Authors:  Yuanzheng Gong; Timothy D Soper; Vivian W Hou; Danying Hu; Blake Hannaford; Eric J Seibel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-12

8.  Standardization and implementation of fluorescence molecular endoscopy in the clinic.

Authors:  Andrea J Sterkenburg; Wouter T R Hooghiemstra; Iris Schmidt; Vasilis Ntziachristos; Wouter B Nagengast; Dimitris Gorpas
Journal:  J Biomed Opt       Date:  2022-02       Impact factor: 3.170

  8 in total