A comparison of VMAT dosimetric verifications between fixed and rotating gantry positions.

Jinhan Zhu1, Lixin Chen, Guanghua Jin, Guangwen Luo, Wufei Cao, Xiaowei Liu.   

Abstract

This study comparatively analysed dose distributions between the fixed and rotating gantry positions of volumetric-modulated arc therapy (VMAT) plans measured using different dosimetric techniques with the intent to provide pre-treatment quality assurance (QA). A total of 12 VMAT plans for the treatment of anatomical sites of various complexities were chosen. An ion chamber was used to measure the absolute central point doses, while EPID, Seven29, Matrixx and Delta4 were used to measure the dose distributions. With the exception of Delta4, all detectors were used in one of two different settings: the gantry was either fixed at 0°, or the gantry was rotating. The results were analysed using the γ-evaluation method. Regarding absolute central point doses, the ion chamber results were within 3% of the treatment planning system (TPS) calculated results. For the dose distributions measured by detectors and calculated by TPS, the γ pass rates, with 3% maximum dose and 3 mm γ criteria, were above 96% when the gantry was fixed at 0°. When the gantry was rotating, the pass rates decreased slightly but were still above 90%. The results obtained from the comparison between the measured and calculated doses demonstrated the reliability of four detectors associated with VMAT. However, the treatment delivery and detector response may impact the results when the gantry is rotating.

Entities:  

Mesh:

Year:  2013        PMID: 23388132     DOI: 10.1088/0031-9155/58/5/1315

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  [Impact of multi-leaf collimator positioning accuracy on quality control of volumetric modulation arc therapy plan for cervical cancer treated with Elekta linear accelerator].

Authors:  J Liang; F Yu; J Zhu; T Song
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2022-07-20

2.  Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine.

Authors:  Jinhan Zhu; Lixin Chen; Along Chen; Guangwen Luo; Xiaowu Deng; Xiaowei Liu
Journal:  Radiat Oncol       Date:  2015-04-11       Impact factor: 3.481

3.  Determination of Multileaf Collimator Positional Errors as a Function of Dose Rate, Speed, and Delivery Interruption for Volumetric-Modulated Arc Therapy Delivery.

Authors:  Soumya Roy; Biplab Sarkar; Anirudh Pradhan
Journal:  J Med Phys       Date:  2021-12-31

4.  Interplay effect of angular dependence and calibration field size of MapCHECK 2 on RapidArc quality assurance.

Authors:  Hosang Jin; Vance P Keeling; Daniel A Johnson; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102