Literature DB >> 23382326

Measurement accuracy of a stand-alone oscillometric central blood pressure monitor: a validation report for Microlife WatchBP Office Central.

Hao-Min Cheng1, Shih-Hsien Sung, Yuan-Ta Shih, Shao-Yuan Chuang, Wen-Chung Yu, Chen-Huan Chen.   

Abstract

BACKGROUND: The superiority of prognostic value of blood pressure (BP) measured at central aorta (CBP) over conventional brachial BP measured by cuff-based BP monitors has reignited the development of new noninvasive techniques for estimating CBP. The present study validated the accuracy of CBP measured by a newly developed stand-alone CBP monitor.
METHODS: The CBP monitor provided readings of brachial systolic BP (SBP), brachial diastolic BP (DBP), central SBP, and central pulse pressure (PP). Brachial PP and central DBP were calculated from the relevant readings. The accuracy of the brachial and central SBP, PP, and DBP was validated against the simultaneously recorded invasively measured central aortic SBP, PP, and DBP, according to the invasive standard requirements for the noninvasive brachial BP monitors from the Association for the Advancement of Medical Instrumentation (AAMI) in 85 subjects (255 measurements; age range, 30-93 years).
RESULTS: The mean differences of cuff BP with reference to the invasively measured central SBP, PP, and DBP were -2.6 ± 9.0, -8.6 ± 11.2, and 6.1 ± 7.0 mm Hg, respectively, with the former two being obviously underestimated at high CBP and overestimated at low CBP. In contrast, the corresponding differences for the central SBP, PP, and DBP measured by the CBP monitor were -0.6 ± 5.5, -0.4 ± 7.0, and -0.2 ± 6.5 mm Hg, respectively, without obvious systematic bias. The distribution of measurement errors for central SBP, PP, and DBP surpassed the AAMI criteria.
CONCLUSION: Central SBP, PP, and DBP can be measured accurately by a stand-alone automatic BP monitor.

Entities:  

Mesh:

Year:  2013        PMID: 23382326     DOI: 10.1093/ajh/hps021

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  11 in total

1.  Patient-Specific Oscillometric Blood Pressure Measurement.

Authors:  Jiankun Liu; Hao-Min Cheng; Chen-Huan Chen; Shih-Hsien Sung; Mohsen Moslehpour; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  IEEE Trans Biomed Eng       Date:  2015-10-15       Impact factor: 4.538

2.  Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Authors:  Willem J Verberk; Hao-Min Cheng; Li-Chih Huang; Chia-Ming Lin; Yao-Pin Teng; Chen-Huan Chen
Journal:  Pulse (Basel)       Date:  2016-02-12

Review 3.  Ambulatory monitoring of central arterial pressure, wave reflections, and arterial stiffness in patients at cardiovascular risk.

Authors:  Stefano Omboni; Ayana Arystan; Bela Benczur
Journal:  J Hum Hypertens       Date:  2021-09-13       Impact factor: 3.012

4.  Patient-Specific Oscillometric Blood Pressure Measurement: Validation for Accuracy and Repeatability.

Authors:  Jiankun Liu; Hao-Min Cheng; Chen-Huan Chen; Shih-Hsien Sung; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  IEEE J Transl Eng Health Med       Date:  2016-12-14       Impact factor: 3.316

5.  Central Blood Pressure Monitoring via a Standard Automatic Arm Cuff.

Authors:  Keerthana Natarajan; Hao-Min Cheng; Jiankun Liu; Mingwu Gao; Shih-Hsien Sung; Chen-Huan Chen; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  Sci Rep       Date:  2017-10-31       Impact factor: 4.379

6.  Impact of immunosuppressive therapy on arterial stiffness in kidney transplantation: are all treatments the same?

Authors:  Edoardo Melilli; Anna Manonelles; Nuria Montero; Josep Grinyo; Alberto Martinez-Castelao; Oriol Bestard; Josep Cruzado
Journal:  Clin Kidney J       Date:  2017-11-23

7.  Guiding Hypertension Management Using Different Blood Pressure Monitoring Strategies (GYMNs study): comparison of three different blood pressure measurement methods: study protocol for a randomized controlled trial.

Authors:  Hao-Min Cheng; Shih-Hsien Sung; Chen-Huan Chen; Wen-Chung Yu; Shu-Mei Yang; Chao-Yu Guo; Shao-Yuan Chuang; Chern-En Chiang
Journal:  Trials       Date:  2019-05-10       Impact factor: 2.279

8.  The Effect of Long-Term Aronia melanocarpa Extract Supplementation on Cognitive Performance, Mood, and Vascular Function: A Randomized Controlled Trial in Healthy, Middle-Aged Individuals.

Authors:  Sanne Ahles; Yala R Stevens; Peter J Joris; David Vauzour; Jos Adam; Eric de Groot; Jogchum Plat
Journal:  Nutrients       Date:  2020-08-17       Impact factor: 5.717

Review 9.  Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization.

Authors:  James E Sharman; Alberto P Avolio; Johannes Baulmann; Athanase Benetos; Jacques Blacher; C Leigh Blizzard; Pierre Boutouyrie; Chen-Huan Chen; Phil Chowienczyk; John R Cockcroft; J Kennedy Cruickshank; Isabel Ferreira; Lorenzo Ghiadoni; Alun Hughes; Piotr Jankowski; Stephane Laurent; Barry J McDonnell; Carmel McEniery; Sandrine C Millasseau; Theodoros G Papaioannou; Gianfranco Parati; Jeong Bae Park; Athanase D Protogerou; Mary J Roman; Giuseppe Schillaci; Patrick Segers; George S Stergiou; Hirofumi Tomiyama; Raymond R Townsend; Luc M Van Bortel; Jiguang Wang; Siegfried Wassertheurer; Thomas Weber; Ian B Wilkinson; Charalambos Vlachopoulos
Journal:  Eur Heart J       Date:  2017-10-01       Impact factor: 29.983

10.  Estimation of Cardiovascular Risk Predictors from Non-Invasively Measured Diametric Pulse Volume Waveforms via Multiple Measurement Information Fusion.

Authors:  Zahra Ghasemi; Jong Chan Lee; Chang-Sei Kim; Hao-Min Cheng; Shih-Hsien Sung; Chen-Huan Chen; Ramakrishna Mukkamala; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2018-07-11       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.