Literature DB >> 23371768

Surface interactions of a W-DLC-coated biomedical AISI 316L stainless steel in physiological solution.

Renato A Antunes1, Nelson Batista de Lima, Márcia de Almeida Rizzutto, Olga Zazuco Higa, Mitiko Saiki, Isolda Costa.   

Abstract

The corrosion stability of a W-DLC coated surgical AISI 316L stainless steel in Hanks' solution has been evaluated. Particle induced X-ray emission (PIXE) measurements were performed to evaluate the incorporation of potentially bioactive elements from the physiological solution. The film structure was analyzed by X-ray diffractometry and micro-Raman spectroscopy. The wear behavior was assessed using the sphere-on-disc geometry. The in vitro biocompatibility of the W-DLC film was evaluated by cytotoxicity tests. The corrosion resistance of the stainless steel substrate decreased in the presence of the PVD layer. EIS measurements suggest that this behavior was closely related to the corrosion attack through the coating pores. PIXE measurements revealed the presence of Ca and P in the W-DLC film after immersion in Hanks' solution. This result shows that the PIXE technique can be applied to identify and evaluate the incorporation of bioactive elements by W-DLC films. The film showed good wear resistance and biocompatibility.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23371768     DOI: 10.1007/s10856-013-4871-z

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  8 in total

1.  Application of stripping voltammetry and microelectrodes in vitro biocompatibility and in vivo toxicity tests of AISI 316L corrosion products.

Authors:  S Morais; M C Pereira
Journal:  J Trace Elem Med Biol       Date:  2000-04       Impact factor: 3.849

2.  Quantitation of platelet adhesion to Ti and DLC-coated Ti in vitro using (125)I-labeled platelets.

Authors:  L K Krishnan; N Varghese; C V Muraleedharan; G S Bhuvaneshwar; F Derangère; Y Sampeur; R Suryanarayanan
Journal:  Biomol Eng       Date:  2002-08

3.  Comparative corrosion study of "Ni-free" austenitic stainless steels in view of medical applications.

Authors:  L Reclaru; R Ziegenhagen; P-Y Eschler; A Blatter; J Lemaître
Journal:  Acta Biomater       Date:  2006-05-05       Impact factor: 8.947

4.  Application of particle-induced X-ray emission to research in biology and medicine.

Authors:  E T Williams
Journal:  Biol Trace Elem Res       Date:  1987-04       Impact factor: 3.738

Review 5.  Tungsten toxicity.

Authors:  Mark L Witten; Paul R Sheppard; Brandon L Witten
Journal:  Chem Biol Interact       Date:  2011-12-13       Impact factor: 5.192

6.  Corrosion fatigue behaviors of two biomedical Mg alloys - AZ91D and WE43 - In simulated body fluid.

Authors:  X N Gu; W R Zhou; Y F Zheng; Y Cheng; S C Wei; S P Zhong; T F Xi; L J Chen
Journal:  Acta Biomater       Date:  2010-07-23       Impact factor: 8.947

7.  Alkali oxide containing mesoporous bioactive glasses: synthesis, characterization and in vitro bioactivity.

Authors:  Chitra Vaid; Sevi Murugavel
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2012-11-24       Impact factor: 7.328

8.  Elemental analysis of renal slices by proton-induced X-ray emission.

Authors:  T Lowe; Q Chen; Q Fernando; R Keith; A J Gandolfi
Journal:  Environ Health Perspect       Date:  1993-09       Impact factor: 9.031

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.