Literature DB >> 16765883

Comparative corrosion study of "Ni-free" austenitic stainless steels in view of medical applications.

L Reclaru1, R Ziegenhagen, P-Y Eschler, A Blatter, J Lemaître.   

Abstract

The role of nickel in the biological response to alloys used in medical devices is of immense significance with regard to toxicology and biological performance. There is now a tendency to take nickel out of alloys for medical applications. However, this needs careful evaluation since no compromise is acceptable with regard to mechanical properties, corrosion resistance or any other harmful consequences due to the nickel substitution. This paper analyses the corrosion behaviour and cations released for five austenitic steels, nominally "nickel-free". The analysis of electrochemical parameters, open circuit potential, polarisation resistance, Tafel slopes, corrosion current, breakdown potential, potentiodynamic polarisation curves, and coulometric analysis by zone, reveal that the new austenitic steels, nominally "nickel-free", do not behave in the same way. In the family of steels studied, quite a large dispersion is noted in the corrosion behaviour. With regard to the crevice corrosion behaviour, the steel grades studied can be classified into three groups, with crevice potentials of 600-650mV; 350-450mV and 100-150mV. The release of 18 cations (Al, Ba, Be, Cd, Co, Cr, Cu, Fe, Li, Mn, Mo, Ni, P, Pb, Sn, Sr, Ti, and V) was studied by extraction tests in artificial sweat and bone plasma fluid. The extraction tests reveal that the "nickel-free" steels indeed release only faint traces of nickel. Yet many other elements, some of them potentially harmful, are released in significant amounts. Generally, the amount of cations released is substantially higher in the artificial sweat solution than in the bone plasma.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16765883     DOI: 10.1016/j.actbio.2006.03.004

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  6 in total

1.  Knowledge of Surgery-Related Allergic Contact Dermatitis among Florida Dermatological Surgeons: A Pilot Study.

Authors:  Panta Rouhani; Robert S Kirsner; Antoine Amado; Lora E Fleming; Keyvan Nouri; Sharon E Jacob
Journal:  J Clin Aesthet Dermatol       Date:  2009-11

2.  Surface interactions of a W-DLC-coated biomedical AISI 316L stainless steel in physiological solution.

Authors:  Renato A Antunes; Nelson Batista de Lima; Márcia de Almeida Rizzutto; Olga Zazuco Higa; Mitiko Saiki; Isolda Costa
Journal:  J Mater Sci Mater Med       Date:  2013-01-31       Impact factor: 3.896

3.  In vitro response of human peripheral blood mononuclear cells to AISI 316L austenitic stainless steel subjected to nitriding and collagen coating treatments.

Authors:  Maria Stio; Maria Martinesi; Cristina Treves; Francesca Borgioli
Journal:  J Mater Sci Mater Med       Date:  2015-02-06       Impact factor: 3.896

4.  Promotion of initial cell adhesion on trisuccinimidyl citrate-modified nickel-free high-nitrogen stainless steel.

Authors:  Makoto Sasaki; Motoki Inoue; Yasuyuki Katada; Tetsushi Taguchi
Journal:  J Mater Sci Mater Med       Date:  2013-01-19       Impact factor: 3.896

5.  The concentrations of IL-8 and IL-6 in gingival crevicular fluid during nickel-chromium alloy porcelain crown restoration.

Authors:  Lufeng Yu; JianSheng Su; DeRong Zou; Zana Mariano
Journal:  J Mater Sci Mater Med       Date:  2013-04-07       Impact factor: 3.896

6.  Comparative Analysis of the Corrosion Resistance of Titanium Alloys Intended to Come into Direct or Prolonged Contact with Live Tissues.

Authors:  Florina Ionescu; Lucien Reclaru; Lavinia Cosmina Ardelean; Andreas Blatter
Journal:  Materials (Basel)       Date:  2019-09-03       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.