Literature DB >> 23369482

Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row.

Nathan A Mall1, Andrew S Lee, Jaskarndip Chahal, Geoffrey S Van Thiel, Anthony A Romeo, Nikhil N Verma, Brian J Cole.   

Abstract

PURPOSE: Double-row and transosseous-equivalent repair techniques have shown greater strength and improved healing than single-row techniques. The purpose of this study was to determine whether tying of the medial-row sutures provides added stability during biomechanical testing of a transosseous-equivalent rotator cuff repair.
METHODS: We performed a systematic review of studies directly comparing biomechanical differences.
RESULTS: Five studies met the inclusion and exclusion criteria. Of the 5 studies, 4 showed improved biomechanical properties with tying the medial-row anchors before bringing the sutures laterally to the lateral-row anchors, whereas the remaining study showed no difference in contact pressure, mean failure load, or gap formation with a standard suture bridge with knots tied at the medial row compared with knotless repairs.
CONCLUSIONS: The results of this systematic review and quantitative synthesis indicate that the biomechanical factors ultimate load, stiffness, gap formation, and contact area are significantly improved when medial knots are tied as part of a transosseous-equivalent suture bridge construct compared with knotless constructs. Further studies comparing the clinical healing rates and functional outcomes between medial knotted and knotless repair techniques are needed. CLINICAL RELEVANCE: This review indicates that biomechanical factors are improved when the medial row of a transosseous-equivalent rotator cuff is tied compared with a knotless repair. However, this has not been definitively proven to translate to improved healing rates clinically.
Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2013        PMID: 23369482     DOI: 10.1016/j.arthro.2012.11.008

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  18 in total

Review 1.  Rotator cuff tears: An evidence based approach.

Authors:  Senthil Nathan Sambandam; Vishesh Khanna; Arif Gul; Varatharaj Mounasamy
Journal:  World J Orthop       Date:  2015-12-18

2.  Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double-Row and Knotless Transosseous-Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study.

Authors:  Taku Hatta; Hugo Giambini; Alexander W Hooke; Chunfeng Zhao; John W Sperling; Scott P Steinmann; Nobuyuki Yamamoto; Eiji Itoi; Kai-Nan An
Journal:  Arthroscopy       Date:  2016-05-04       Impact factor: 4.772

3.  A biomechanical study of the medial row tightening on stability of single stitch suture-bridge construct.

Authors:  Sharon Abihssira; Pierre-Alban Bouche; Claire Cammas; Clément Thirache; Geoffroy Nourissat
Journal:  J Orthop Surg Res       Date:  2022-07-15       Impact factor: 2.677

4.  Arthroscopic knotless rotator cuff repair: Factors associated with construct selection and recent trends from a manual review of 1617 cases.

Authors:  Sarav S Shah; Aalok Shah; Vivek Chadayammuri; Marlena McGill; Nicole Wei; David V Tuckman; Nicholas A Sgaglione
Journal:  J Orthop       Date:  2018-01-31

5.  Is it necessary to tie the medial row in rotator cuff repair double-row constructs when using suture tape?

Authors:  Michael R Mijares; Andrew Hiller; Ali Alhandi; David Kaimrajh; Ted Milne; Loren Latta; Michael G Baraga
Journal:  J Clin Orthop Trauma       Date:  2020-02-21

6.  Biomechanical Comparison of Modified Suture Bridge Using Rip-Stop versus Traditional Suture Bridge for Rotator Cuff Repair.

Authors:  ZiYing Wu; Chong Zhang; Peng Zhang; TianWu Chen; ShiYi Chen; JiWu Chen
Journal:  Biomed Res Int       Date:  2016-11-15       Impact factor: 3.411

7.  Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone.

Authors:  Y Ono; J M Woodmass; A A Nelson; R S Boorman; G M Thornton; I K Y Lo
Journal:  Bone Joint Res       Date:  2016-06       Impact factor: 5.853

8.  Optimizing the Double-Row Construct: An Untied Medial Row Demonstrates Equivalent Mean Contact Pressures in a Rotator Cuff Model.

Authors:  Austin V Stone; T David Luo; Aman Sharma; Kerry A Danelson; Michael De Gregorio; Michael T Freehill
Journal:  Orthop J Sports Med       Date:  2020-04-27

9.  Modified Double-Row Suture Bridge Technique With Double-Row Biceps Tenodesis for Massive Rotator Cuff Tear.

Authors:  Joseph Maalouly; Dany Aouad; Antonios Tawk; Georges El Rassi
Journal:  Arthrosc Tech       Date:  2020-05-23

Review 10.  A Systematic Summary of Systematic Reviews on the Topic of the Rotator Cuff.

Authors:  Jeffrey Jancuska; John Matthews; Tyler Miller; Melissa A Kluczynski; Leslie J Bisson
Journal:  Orthop J Sports Med       Date:  2018-09-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.