Accurate superimposition of perimetry data onto fundus photographs.

T Bek1, H Lund-Andersen.   

Abstract

A technique for accurate superimposition of computerized perimetry data onto the corresponding retinal locations seen on fundus photographs was developed. The technique was designed to take into account: 1) that the photographic field of view of the fundus camera varies with ametropia-dependent camera focusing 2) possible distortion by the fundus camera, and 3) that corrective lenses employed during perimetry magnify or minify the visual field. The technique allowed an overlay of perimetry data of the central 60 degrees of the visual field onto fundus photographs with an accuracy of 0.5 degree. The correlation of localized retinal morphology to localized retinal function was therefore limited by the spatial resolution of the computerized perimetry, which was 2.5 degrees in the Dicon AP-2500 perimeter employed for this study. The theoretical assumptions of the technique were confirmed by comparing visual field records to fundus photographs from patients with morphologically well-defined non-functioning lesions in the retina.

Entities:  

Mesh:

Year:  1990        PMID: 2336927     DOI: 10.1111/j.1755-3768.1990.tb01642.x

Source DB:  PubMed          Journal:  Acta Ophthalmol (Copenh)        ISSN: 0001-639X


  6 in total

1.  Diabetes and retinal function.

Authors:  J A Roth
Journal:  Br J Ophthalmol       Date:  1990-11       Impact factor: 4.638

2.  Localised blood-retinal barrier leakage and retinal light sensitivity in diabetic retinopathy.

Authors:  T Bek; H Lund-Andersen
Journal:  Br J Ophthalmol       Date:  1990-07       Impact factor: 4.638

3.  Cotton-wool spots and retinal light sensitivity in diabetic retinopathy.

Authors:  T Bek; H Lund-Andersen
Journal:  Br J Ophthalmol       Date:  1991-01       Impact factor: 4.638

4.  Angioscotomata and morphological features of related vessels in automated perimetry.

Authors:  A B Safran; A Halfon; E Safran; C Mermoud
Journal:  Br J Ophthalmol       Date:  1995-02       Impact factor: 4.638

5.  Reduced baseline diameter and contraction of peripheral retinal arterioles immediately after remote ischemia in diabetic patients.

Authors:  Yasmin El Dabagh; Line Petersen; Michael Pedersen; Toke Bek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-07-04       Impact factor: 3.117

6.  Short wavelength automated perimetry can detect visual field changes in diabetic patients without retinopathy.

Authors:  Othman Ali Zico; Amany Abdel-Fattah El-Shazly; Eslam Elsayed Abdel-Hamid Ahmed
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.