Literature DB >> 23369158

Assessing feasibility of real-time ultrasound monitoring in stereotactic body radiotherapy of liver tumors.

Yahua Zhong1, Kevin Stephans, Peng Qi, Naiching Yu, John Wong, Ping Xia.   

Abstract

To monitor tumor motion during stereotactic body radiotherapy (SBRT) for patients with liver cancer, an integrated ultrasound and kilo-voltage cone-beam computed tomography (KV-CBCT) system has been proposed. The presence of an ultrasound probe may interfere with the radiation beams. The purpose of this study is to minimize this interference by altering orientations of the ultrasound probe and directions of radiation beams while not compromising the quality of SBRT plans. Ten patients, who received SBRT of liver cancer, were randomly selected for this study. To simulate the presence of an ultrasound probe, a virtual probe was oriented either parallel or vertical to the longitudinal axis of the patient's body and was added on the surface of the patient's body at the nearest location to the tumor. For both the parallel and vertical probe orientations, 2 new SBRT (Probe-Para and Probe-Vert) plans that minimize the interference between the probe and radiation beams were created for each patient. These SBRT plans were compared to the original clinically accepted SBRT plans, with a treatment goal of 37.5 Gy to the planning target volume (PTV) in 3 fractions. Specific dosimetric endpoints were evaluated, including doses to 95% (D95), of the PTV plan conformal index (CI), homogeneity index (HI), and relevant endpoint doses to organs at risk. For 2 patients with superficially located tumors, no clinically acceptable SBRT plans could be produced without the interference between the probe and radiation beams. For the remaining 8 patients, the Probe-Para plans allowed 7 patients to be treated with coplanar radiation beams (without moving the treatment couch during treatment) and 1 patient to be treated with non-coplanar beams (by moving the treatment couch during treatment). The Probe-Vert plans allowed 2 patients to be treated with coplanar beams and 6 patients to be treated with non-coplanar beams. The average D95 of the PTV were 38.63 Gy ± 0.14 (р = 0.65) for Probe-Para plans, 38.48 Gy ± 0.31 (р = 0.33) for Probe-Vert plans, and 38.72 Gy ± 0.14 for clinical SBRT plans. There were no significant differences (p > 0.05) in CI and HI of all SBRT plans. The endpoint doses to the liver, heart, esophagus, right kidney, and stomach also had no significant differences (p > 0.05). Except for superficial lesions, real-time ultrasound monitoring during liver SBRT is clinically feasible. Placing the ultrasound probe parallel to the longitudinal axis of the patient allows a greater probability of utilizing preferred coplanar beams.

Entities:  

Mesh:

Year:  2013        PMID: 23369158     DOI: 10.7785/tcrt.2012.500323

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  11 in total

1.  Monte Carlo modeling of ultrasound probes for image guided radiotherapy.

Authors:  Magdalena Bazalova-Carter; Jeffrey Schlosser; Josephine Chen; Dimitre Hristov
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

2.  Analysis and optimization of the robot setup for robotic-ultrasound-guided radiation therapy.

Authors:  Matthias Schlüter; Stefan Gerlach; Christoph Fürweger; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-06-06       Impact factor: 2.924

3.  Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

Authors:  Jeffrey Schlosser; Ren Hui Gong; Ralf Bruder; Achim Schweikard; Sungjune Jang; John Henrie; Aya Kamaya; Albert Koong; Daniel T Chang; Dimitre Hristov
Journal:  Med Phys       Date:  2016-11       Impact factor: 4.071

4.  A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy.

Authors:  Saber Nankali; Ahmad Esmaili Torshabi; Payam Samadi Miandoab
Journal:  Technol Cancer Res Treat       Date:  2016-07-09

5.  A block matching based approach with multiple simultaneous templates for the real-time 2D ultrasound tracking of liver vessels.

Authors:  Andrew J Shepard; Bo Wang; Thomas K F Foo; Bryan P Bednarz
Journal:  Med Phys       Date:  2017-10-13       Impact factor: 4.071

Review 6.  Ultrasound Imaging in Radiation Therapy: From Interfractional to Intrafractional Guidance.

Authors:  Craig Western; Dimitre Hristov; Jeffrey Schlosser
Journal:  Cureus       Date:  2015-06-20

7.  Markerless Respiratory Tumor Motion Prediction Using an Adaptive Neuro-fuzzy Approach.

Authors:  Nima Rostampour; Keyvan Jabbari; Mahdad Esmaeili; Mohammad Mohammadi; Shahabedin Nabavi
Journal:  J Med Signals Sens       Date:  2018 Jan-Mar

8.  Optimum location of external markers using feature selection algorithms for real-time tumor tracking in external-beam radiotherapy: a virtual phantom study.

Authors:  Saber Nankali; Ahmad Esmaili Torshabi; Payam Samadi Miandoab; Amin Baghizadeh
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

9.  Investigation of the optimum location of external markers for patient setup accuracy enhancement at external beam radiotherapy.

Authors:  Payam Samadi Miandoab; Ahmad Esmaili Torshabi; Saber Nankali
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

10.  The technical design and concept of a PET/CT linac for biology-guided radiotherapy.

Authors:  Oluwaseyi M Oderinde; Shervin M Shirvani; Peter D Olcott; Gopinath Kuduvalli; Samuel Mazin; David Larkin
Journal:  Clin Transl Radiat Oncol       Date:  2021-04-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.