Literature DB >> 23367458

A framework for personalization of coronary flow computations during rest and hyperemia.

Puneet Sharma1, Lucian Itu, Xudong Zheng, Ali Kamen, Dominik Bernhardt, Constantin Suciu, Dorin Comaniciu.   

Abstract

We introduce a Computational Fluid Dynamics (CFD) based method for performing patient-specific coronary hemodynamic computations under two conditions: at rest and during drug-induced hyperemia. The proposed method is based on a novel estimation procedure for determining the boundary conditions from non-invasively acquired patient data at rest. A multi-variable feedback control framework ensures that the computed mean arterial pressure and the flow distribution matches the estimated values for an individual patient during the rest state. The boundary conditions at hyperemia are derived from the respective rest-state values via a transfer function that models the vasodilation phenomenon. Simulations are performed on a coronary tree where a 65% diameter stenosis is introduced in the left anterior descending (LAD) artery, with the boundary conditions estimated using the proposed method. The results demonstrate that the estimation of the hyperemic resistances is crucial in order to obtain accurate values for pressure and flow rates. Results from an exhaustive sensitivity analysis have been presented for analyzing the variability of trans-stenotic pressure drop and Fractional Flow Reserve (FFR) values with respect to various measurements and assumptions.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23367458     DOI: 10.1109/EMBC.2012.6347523

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  9 in total

1.  Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements--initial experience with a novel physician-driven algorithm.

Authors:  Stefan Baumann; Rui Wang; U Joseph Schoepf; Daniel H Steinberg; James V Spearman; Richard R Bayer; Christian W Hamm; Matthias Renker
Journal:  Eur Radiol       Date:  2014-11-18       Impact factor: 5.315

2.  The effect of blood pressure on non-invasive fractional flow reserve derived from coronary computed tomography angiography.

Authors:  Akira Kurata; Adriaan Coenen; Marisa M Lubbers; Koen Nieman; Teruhito Kido; Tomoyuki Kido; Natsumi Yamashita; Kouki Watanabe; Gabriel P Krestin; Teruhito Mochizuki
Journal:  Eur Radiol       Date:  2016-08-19       Impact factor: 5.315

Review 3.  [Computed tomography in patients with chronic stable angina : Fractional flow reserve measurement].

Authors:  M Renker; U J Schoepf; T Becher; N Krampulz; W Kim; A Rolf; H Möllmann; C W Hamm; T Henzler; M Borggrefe; I Akin; S Baumann
Journal:  Herz       Date:  2016-06-02       Impact factor: 1.443

Review 4.  CT-based myocardial ischemia evaluation: quantitative angiography, transluminal attenuation gradient, myocardial perfusion, and CT-derived fractional flow reserve.

Authors:  Hyun Jung Koo; Dong Hyun Yang; Young-Hak Kim; Joon-Won Kang; Soo-Jin Kang; Jihoon Kweon; Hyun Jung Kim; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2015-12-14       Impact factor: 2.357

5.  Comparison of Computed Tomography derived Fractional Flow Reserve to invasive Fractional Flow Reserve in Diagnosis of Functional Coronary Stenosis: A Meta-Analysis.

Authors:  Pradyumna Agasthi; Arun Kanmanthareddy; Charl Khalil; Obiora Egbuche; Vivek Yarlagadda; Rajesh Sachdeva; Reza Arsanjani
Journal:  Sci Rep       Date:  2018-08-01       Impact factor: 4.379

6.  Diagnostic Accuracy of a Novel On-site Virtual Fractional Flow Reserve Parallel Computing System.

Authors:  Hyung Bok Park; Yeonggul Jang; Reza Arsanjani; Minh Tuan Nguyen; Sang Eun Lee; Byunghwan Jeon; Sunghee Jung; Youngtaek Hong; Seongmin Ha; Sekeun Kim; Sang Wook Lee; Hyuk Jae Chang
Journal:  Yonsei Med J       Date:  2020-02       Impact factor: 2.759

7.  Diagnostic performance of CT-derived resting distal to aortic pressure ratio (resting Pd/Pa) vs. CT-derived fractional flow reserve (CT-FFR) in coronary lesion severity assessment.

Authors:  Quan Li; Yang Zhang; Chunliang Wang; Shiming Dong; Yijin Mao; Yida Tang; Yong Zeng
Journal:  Ann Transl Med       Date:  2021-09

8.  Non-Invasive Quantification of Fraction Flow Reserve Based on Steady-State Geometric Multiscale Models.

Authors:  Jincheng Liu; Xue Wang; Bao Li; Suqin Huang; Hao Sun; Liyuan Zhang; Yutong Sun; Zhuo Liu; Jian Liu; Lihua Wang; Xi Zhao; Wenxin Wang; Mingzi Zhang; Youjun Liu
Journal:  Front Physiol       Date:  2022-04-12       Impact factor: 4.755

Review 9.  Noninvasive FFR derived from coronary CT angiography in the management of coronary artery disease: technology and clinical update.

Authors:  Rine Nakanishi; Mathew J Budoff
Journal:  Vasc Health Risk Manag       Date:  2016-06-22
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.