Literature DB >> 23366381

DWI based thermometry: the effects of b-values, resolutions, signal-to-noise ratio, and magnet strength.

Koji Sakai1, Ryo Sakamoto, Tomohisa Okada, Naozo Sugimoto, Kaori Togashi.   

Abstract

Among MR methods, the most clinically applicable temperature measurement method at deep brain might be the diffusion-weighted image (DWI) thermometry. Although only applicable to cerebrospinal fluid (CSF), it is thought to be potentially useful in assessing the thermal pathophysiology of the brain in both patients and healthy subjects. The purpose of this study was to investigate the effects of b-value, pixel resolution, magnet strength and signal to noise ratio (SNR) for the DWI-thermometry with healthy volunteer. Formerly, an ADC from b=0 and b=1000 has been thought to be useful for diffusion thermometry, this study revealed b=200 to 800 was more appropriate for DWI thermometry. The SNR was strongly affected the results of DWI thermometry.

Entities:  

Mesh:

Year:  2012        PMID: 23366381     DOI: 10.1109/EMBC.2012.6346420

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Assessment of brain temperatures during different phases of the menstrual cycle using diffusion-weighted imaging thermometry.

Authors:  Taro Tsukamoto; Taro Shimono; Asari Sai; Koji Sakai; Akira Yamamoto; Shinichi Sakamoto; Yukio Miki
Journal:  Jpn J Radiol       Date:  2016-02-04       Impact factor: 2.374

2.  Altered coupling of spontaneous brain activities and brain temperature in patients with adolescent-onset, first-episode, drug-naïve schizophrenia.

Authors:  Zhiyong Zhao; Guojun Xu; Bin Sun; Xuzhou Li; Zhe Shen; Shangda Li; Yi Xu; Manli Huang; Dongrong Xu
Journal:  Neuroradiology       Date:  2019-03-06       Impact factor: 2.804

3.  Can we shorten the q-space imaging to make it clinically feasible?

Authors:  Koji Sakai; Kei Yamada; Kentaro Akazawa; Jun Tazoe; Masashi Yasuike; Hitomi Nagano; Hiroyasu Ikeno; Toshiaki Nakagawa
Journal:  Jpn J Radiol       Date:  2016-11-02       Impact factor: 2.374

4.  Effects of motion and b-value on apparent temperature measurement by diffusion-based thermometry MRI: eye vitreous study.

Authors:  Jamal J Derakhshan; Neda Parvin; Laurie A Loevner; Felix W Wehrli; Robert C McKinstry
Journal:  Med Phys       Date:  2020-09-02       Impact factor: 4.071

5.  Therapeutic hypothermia modifies perinatal asphyxia-induced changes of the corpus callosum and outcome in neonates.

Authors:  Thomas Alderliesten; Linda S de Vries; Yara Khalil; Ingrid C van Haastert; Manon J N L Benders; Corine Koopman-Esseboom; Floris Groenendaal
Journal:  PLoS One       Date:  2015-04-29       Impact factor: 3.240

  5 in total