Literature DB >> 23363204

Computational fluid dynamics evaluation of the cross-limb stent graft configuration for endovascular aneurysm repair.

Tina L T Shek1, Leonard W Tse, Aydin Nabovati, Cristina H Amon.   

Abstract

The technique of crossing the limbs of bifurcated modular stent grafts for endovascular aneurysm repair (EVAR) is often employed in the face of splayed aortic bifurcations to facilitate cannulation and prevent device kinking. However, little has been reported about the implications of cross-limb EVAR, especially in comparison to conventional EVAR. Previous computational fluid dynamics studies of conventional EVAR grafts have mostly utilized simplified planar stent graft geometries. We herein examined the differences between conventional and cross-limb EVAR by comparing their hemodynamic flow fields (i.e., in the "direct" and "cross" configurations, respectively). We also added a "planar" configuration, which is commonly found in the literature, to identify how well this configuration compares to out-of-plane stent graft configurations from a hemodynamic perspective. A representative patient's cross-limb stent graft geometry was segmented using computed tomography imaging in Mimics software. The cross-limb graft geometry was used to build its direct and planar counterparts in SolidWorks. Physiologic velocity and mass flow boundary conditions and blood properties were implemented for steady-state and pulsatile transient simulations in ANSYS CFX. Displacement forces, wall shear stress (WSS), and oscillatory shear index (OSI) were all comparable between the direct and cross configurations, whereas the planar geometry yielded very different predictions of hemodynamics compared to the out-of-plane stent graft configurations, particularly for displacement forces. This single-patient study suggests that the short-term hemodynamics involved in crossing the limbs is as safe as conventional EVAR. Higher helicity and improved WSS distribution of the cross-limb configuration suggest improved flow-related thrombosis resistance in the short term. However, there may be long-term fatigue implications to stent graft use in the cross configuration when compared to the direct configuration.

Entities:  

Mesh:

Year:  2012        PMID: 23363204     DOI: 10.1115/1.4007950

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  5 in total

1.  Numerical and Experimental Investigation of the Hemodynamic Performance of Bifurcated Stent Grafts with Various Torsion Angles.

Authors:  Ming Liu; Anqiang Sun; Xiaoyan Deng
Journal:  Sci Rep       Date:  2018-08-22       Impact factor: 4.379

2.  Hemodynamic performance within crossed stent grafts: computational and experimental study on the effect of cross position and angle.

Authors:  Ming Liu; Anqiang Sun; Xiaoyan Deng
Journal:  Biomed Eng Online       Date:  2018-06-19       Impact factor: 2.819

3.  Comparative evaluation of ballet-type and conventional stent graft configurations for endovascular aneurysm repair: A CFD analysis.

Authors:  Fahmida Ashraf; Tehmina Ambreen; Cheol Woo Park; Dong-Ik Kim
Journal:  Clin Hemorheol Microcirc       Date:  2021       Impact factor: 2.375

4.  A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck.

Authors:  Ming Qing; Yue Qiu; Jiarong Wang; Tinghui Zheng; Ding Yuan
Journal:  Front Physiol       Date:  2021-12-02       Impact factor: 4.566

5.  Numerical and Experimental Investigation of Novel Blended Bifurcated Stent Grafts with Taper to Improve Hemodynamic Performance.

Authors:  Ming Liu; Zhenze Wang; Anqiang Sun; Xiaoyan Deng
Journal:  Comput Math Methods Med       Date:  2018-09-09       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.