Literature DB >> 23362246

Increasing the automation of a 2D-3D registration system.

Andreas Varnavas1, Tom Carrell, Graeme Penney.   

Abstract

Routine clinical use of 2D-3D registration algorithms for Image Guided Surgery remains limited. A key aspect for routine clinical use of this technology is its degree of automation, i.e., the amount of necessary knowledgeable interaction between the clinicians and the registration system. Current image-based registration approaches usually require knowledgeable manual interaction during two stages: for initial pose estimation and for verification of produced results. We propose four novel techniques, particularly suited to vertebra-based registration systems, which can significantly automate both of the above stages. Two of these techniques are based upon the intraoperative "insertion" of a virtual fiducial marker into the preoperative data. The remaining two techniques use the final registration similarity value between multiple CT vertebrae and a single fluoroscopy vertebra. The proposed methods were evaluated with data from 31 operations (31 CT scans, 419 fluoroscopy images). Results show these methods can remove the need for manual vertebra identification during initial pose estimation, and were also very effective for result verification, producing a combined true positive rate of 100% and false positive rate equal to zero. This large decrease in required knowledgeable interaction is an important contribution aiming to enable more widespread use of 2D-3D registration technology.

Mesh:

Year:  2013        PMID: 23362246     DOI: 10.1109/TMI.2012.2227337

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm.

Authors:  A Duménil; A Kaladji; M Castro; C Göksu; A Lucas; P Haigron
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-26       Impact factor: 2.924

2.  A framework for automatic creation of gold-standard rigid 3D-2D registration datasets.

Authors:  Hennadii Madan; Franjo Pernuš; Boštjan Likar; Žiga Špiclin
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-09-21       Impact factor: 2.924

3.  Pose-aware C-arm for automatic re-initialization of interventional 2D/3D image registration.

Authors:  Javad Fotouhi; Bernhard Fuerst; Alex Johnson; Sing Chun Lee; Russell Taylor; Greg Osgood; Nassir Navab; Mehran Armand
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-19       Impact factor: 2.924

4.  Registration of MRI to intraoperative radiographs for target localization in spinal interventions.

Authors:  T De Silva; A Uneri; M D Ketcha; S Reaungamornrat; J Goerres; M W Jacobson; S Vogt; G Kleinszig; A J Khanna; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-01-04       Impact factor: 3.609

5.  3D–2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation.

Authors:  Yoshito Otake; Adam S Wang; Ali Uneri; Gerhard Kleinszig; Sebastian Vogt; Nafi Aygun; Sheng-fu L Lo; Jean-Paul Wolinsky; Ziya L Gokaslan; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-03-07       Impact factor: 3.609

6.  Robust 3D-2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation.

Authors:  Yoshito Otake; Adam S Wang; J Webster Stayman; Ali Uneri; Gerhard Kleinszig; Sebastian Vogt; A Jay Khanna; Ziya L Gokaslan; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-11-18       Impact factor: 3.609

Review 7.  Recent Trends, Technical Concepts and Components of Computer-Assisted Orthopedic Surgery Systems: A Comprehensive Review.

Authors:  Jan Kubicek; Filip Tomanec; Martin Cerny; Dominik Vilimek; Martina Kalova; David Oczka
Journal:  Sensors (Basel)       Date:  2019-11-27       Impact factor: 3.576