Literature DB >> 23358572

Dynamic pH mapping in microfluidic devices by integrating adaptive coatings based on polyaniline with colorimetric imaging techniques.

Larisa Florea1, Cormac Fay, Emer Lahiff, Thomas Phelan, Noel E O'Connor, Brian Corcoran, Dermot Diamond, Fernando Benito-Lopez.   

Abstract

In this paper we present a microfluidic device that has integrated pH optical sensing capabilities based on polyaniline. The optical properties of polyaniline coatings change in response to the pH of the solution that is flushed inside the microchannel offering the possibility of monitoring pH in continuous flow over a wide pH range throughout the entire channel length. This work also features an innovative detection system for spatial localisation of chemical pH gradients along microfluidic channels through the use of a low cost optical device. Specifically, the use of a microfluidic channel coated with polyaniline is shown to respond colorimetrically to pH and that effect is detected by the detection system, even when pH gradients are induced within the channel. This study explores the capability of detecting this gradient by means of imaging techniques and the mapping of the camera's response to its corresponding pH after a successful calibration process. The provision of an inherently responsive channel means that changes in the pH of a sample moving through the system can be detected dynamically using digital imaging along the entire channel length in real time, without the need to add reagents to the sample. This approach is generic and can be applied to other chemically responsive coatings immobilised on microchannels.

Entities:  

Year:  2013        PMID: 23358572     DOI: 10.1039/c2lc41065f

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  5 in total

1.  Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications.

Authors:  Andreas Steinegger; Otto S Wolfbeis; Sergey M Borisov
Journal:  Chem Rev       Date:  2020-11-04       Impact factor: 60.622

2.  A Flexible Optical pH Sensor Based on Polysulfone Membranes Coated with pH-Responsive Polyaniline Nanofibers.

Authors:  Nedal Abu-Thabit; Yunusa Umar; Elaref Ratemi; Ayman Ahmad; Faraj Ahmad Abuilaiwi
Journal:  Sensors (Basel)       Date:  2016-06-27       Impact factor: 3.576

Review 3.  Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals.

Authors:  Noel S Ha; Saman Sadeghi; R Michael van Dam
Journal:  Micromachines (Basel)       Date:  2017-11-21       Impact factor: 2.891

Review 4.  Autonomous and In Situ Ocean Environmental Monitoring on Optofluidic Platform.

Authors:  Fang Wang; Jiaomeng Zhu; Longfei Chen; Yunfeng Zuo; Xuejia Hu; Yi Yang
Journal:  Micromachines (Basel)       Date:  2020-01-08       Impact factor: 2.891

5.  Flexible pH sensor based on a conductive PANI membrane for pH monitoring.

Authors:  Yongqian Li; Yunlong Mao; Chi Xiao; Xiaoli Xu; Xueyong Li
Journal:  RSC Adv       Date:  2019-12-23       Impact factor: 4.036

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.