Measurement of lower limb volume: agreement between the vertically oriented perometer and a tape measure method.

Chee-Wee Tan1, Fiona Coutts, Cathy Bulley.   

Abstract

OBJECTIVE: To investigate the agreement between lower limb volume measurements for the vertically oriented perometer and a tape measure method.
DESIGN: Between-methods agreement and test-retest reliability study.
SETTING: University setting. PARTICIPANTS: Thirty university staff and students were recruited using convenience sampling with no participant drop-outs.
INTERVENTIONS: All participants' dominant lower limb volumes were measured using the vertically oriented perometer and a tape measure method. MAIN OUTCOME MEASURES: The Bland-Altman difference plot was reported for determining the bias between the two methods and its 95% confidence interval. Test-retest reliability and the measurement error for the perometer method were determined using the ICC(2,1) model and within-subject standard deviation (sw) respectively.
RESULTS: There was a lack of agreement between the tape measure and perometer method. The Bland-Altman difference plot showed that the tape measure method overestimated limb volume by 157ml compared to the perometer method. A 95% confidence interval of -834ml to 519ml was observed. The test-retest reliability of the perometer method was ICC(2,1)=0.99. The measurement error of the perometer method was clinically acceptable (sw=121ml).
CONCLUSIONS: There was a lack of agreement between the two methods investigated. Therefore the perometer and tape measure methods are not interchangeable. It is recommended that future validity and reliability studies for the vertically oriented perometer are conducted on clinical populations.
Copyright © 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CV; ICC; Lower extremity; Rehabilitation; Reliability and validity; coefficient of variation; intraclass correlation; s(w); within subject standard deviation (measurement error)

Mesh:

Year:  2013        PMID: 23351956     DOI: 10.1016/j.physio.2012.12.004

Source DB:  PubMed          Journal:  Physiotherapy        ISSN: 0031-9406            Impact factor:   3.358


  7 in total

1.  Compression Stockings versus Neuromuscular Electrical Stimulation Devices in the Management of Occupational Leg Swelling.

Authors:  J Wou; K J Williams; A H Davies
Journal:  Int J Angiol       Date:  2015-08-31

2.  Impedance of Extracellular Fluid, Volume, and Local Tissue Water Can Be Reliably Measured in People With Lower Limb Lymphedema.

Authors:  Charlotta Jönsson; Karin Johansson; Maria Bjurberg; Christina Brogårdh
Journal:  Phys Ther       Date:  2022-05-05

3.  Measurement Issues in Anthropometric Measures of Limb Volume Change in Persons at Risk for and Living with Lymphedema: A Reliability Study.

Authors:  Dorit Tidhar; Jane M Armer; Daniel Deutscher; Chi-Ren Shyu; Josef Azuri; Richard Madsen
Journal:  J Pers Med       Date:  2015-09-30

4.  Investigation of Shape with Patients Suffering from Unilateral Lymphoedema.

Authors:  Kevork Karakashian; Lawrence Shaban; Cheryl Pike; Raoul van Loon
Journal:  Ann Biomed Eng       Date:  2017-09-20       Impact factor: 3.934

5.  Measurements agreement between low-cost and high-level handheld 3D scanners to scan the knee for designing a 3D printed knee brace.

Authors:  Yoann Dessery; Jari Pallari
Journal:  PLoS One       Date:  2018-01-10       Impact factor: 3.240

6.  Effectiveness of acupuncture for breast cancer related lymphedema: protocol for a single-blind, sham-controlled, randomized, multicenter trial.

Authors:  Huiru Zhu; Jinwan Li; Zheng Peng; Yujie Huang; Xiaolan Lv; Liuying Song; Gechen Zhou; Shengzhang Lin; Jifei Chen; Baoyu He; Fengxian Qin; Xumexiang Liu; Meiyu Dai; Yan Zou; Shengming Dai
Journal:  BMC Complement Altern Med       Date:  2017-09-21       Impact factor: 3.659

7.  Estimates for Assessment of Lymphedema: Reliability and Validity of Extremity Measurements.

Authors:  Frans Houwen; Johannes Stemkens; Peter J de Schipper; Pim van der Wouw; Martijn Heitink; Herman van Langen
Journal:  Lymphat Res Biol       Date:  2021-03-22       Impact factor: 2.589

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.