Literature DB >> 23347377

A preliminary report on the usage of an intracorporal antibiotic cast with synthetic high purity CaSO4 for the treatment of infected penile implant.

Kelly Swords1, Daniel R Martinez, Jorge L Lockhart, Rafael Carrion.   

Abstract

INTRODUCTION: Currently, the surgical treatment of infected penile prostheses is complete removal and either immediate salvage procedure, which carries a significant infection risk, or delayed implantation. With delayed implantation the risk of infection is lower, but the patient loses penile length and width due to corporal fibrosis. AIM: We present our experience with the use of a novel temporary synthetic high purity calcium sulfate (SHPCaSO4) component that acts as a "spacer" at the time of removal of an infected prosthesis while providing constant delivery of local antibiotic elution to the infected area. MAIN OUTCOME MEASURES: Demonstrate that the use of a novel material, SHPCaSO4, can be an innovative way to bridge the gap between removal of an infected penile implant and delayed reimplantation.
METHODS: Two patients (Patient A and B) presented with pain and erythema and were found to have infected malleable penile prosthesis. Both underwent removal of all infected components, and sent for tissue culture. The SHPCaSO4 was mixed with vancomycin and tobramycin, allowed to set up for 5 minutes, and then injected into the corporal space followed by closure with 2-0 Vicryl sutures. The injected SHPCaSO4 was palpable in the penile shaft both proximally and distally, as an "intracorporal casts."
RESULTS: Patients denied pain postoperatively. Delayed implantation occurred at 6 weeks for patient A. This went uneventful and a new three-piece inflatable implant was inserted. Patient B underwent salvage placement of right malleable implant at 15 weeks, and here significant corporal fibrosis was encountered. Patients have had no infection since their delayed implantation (mean follow-up 4 months).
CONCLUSIONS: Data in reference to SHPCaSO4 shows that this product dissolves in approximately 4-6 weeks. This may account for the difference in the ease of delayed implantation between the two patients. Further investigation is warranted.
© 2013 International Society for Sexual Medicine.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23347377     DOI: 10.1111/jsm.12060

Source DB:  PubMed          Journal:  J Sex Med        ISSN: 1743-6095            Impact factor:   3.802


  13 in total

Review 1.  Strategies for penile prosthesis placement in Peyronie's disease and corporal fibrosis.

Authors:  Faysal A Yafi; Premsant Sangkum; Ian Ross McCaslin; Wayne J G Hellstrom
Journal:  Curr Urol Rep       Date:  2015-04       Impact factor: 3.092

Review 2.  Current Status for Semirigid Penile Prosthetic Devices.

Authors:  Raul E Fernandez-Crespo; Kristina Buscaino; Justin Parker; Rafael Carrion
Journal:  Curr Urol Rep       Date:  2021-01-09       Impact factor: 3.092

Review 3.  New advances in erectile technology.

Authors:  Marshall J Stein; Haocheng Lin; Run Wang
Journal:  Ther Adv Urol       Date:  2014-02

Review 4.  Significance of biofilm for the prosthetic surgeon.

Authors:  R Charles Welliver; Brittney L Hanerhoff; Gerard D Henry; Tobias S Köhler
Journal:  Curr Urol Rep       Date:  2014-06       Impact factor: 3.092

5.  Antibiotic-loaded synthetic calcium sulfate beads for prevention of bacterial colonization and biofilm formation in periprosthetic infections.

Authors:  R P Howlin; M J Brayford; J S Webb; J J Cooper; S S Aiken; P Stoodley
Journal:  Antimicrob Agents Chemother       Date:  2014-10-13       Impact factor: 5.191

6.  Local release of antibiotics for surgical site infection management using high-purity calcium sulfate: an in vitro elution study.

Authors:  Sean S Aiken; John J Cooper; Hannah Florance; Matthew T Robinson; Stephen Michell
Journal:  Surg Infect (Larchmt)       Date:  2014-08-22       Impact factor: 2.150

Review 7.  Current management of penile implant infections, device reliability, and optimizing cosmetic outcome.

Authors:  John J Mulcahy; Andrew Kramer; William O Brant; Justin L Parker; Paul E Perito; Jeremy B Myers; Richard Bryson; Meagan Dunne
Journal:  Curr Urol Rep       Date:  2014-06       Impact factor: 3.092

Review 8.  Salvage penile prosthetic surgery utilizing temporary malleable implants.

Authors:  Michael Lao; R James Graydon; Jared M Bieniek
Journal:  Transl Androl Urol       Date:  2017-11

9.  Evaluation of comparative soft tissue response to bone void fillers with antibiotics in a rabbit intramuscular model.

Authors:  Rema A Oliver; Vedran Lovric; Chris Christou; William R Walsh
Journal:  J Biomater Appl       Date:  2019-04-16       Impact factor: 2.646

10.  Development of a Novel Model for the Assessment of Dead-Space Management in Soft Tissue.

Authors:  Rema A Oliver; Vedran Lovric; Yan Yu; Chris Christou; Sean S Aiken; John J Cooper; William R Walsh
Journal:  PLoS One       Date:  2015-08-25       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.