Literature DB >> 2334326

Assessment of intraocular pressure in vitrectomized gas-containing eyes. A clinical and manometric comparison of the Tono-Pen to the pneumotonometer.

J I Lim1, N P Blair, E J Higginbotham, M D Farber, W E Shaw, B R Garretson.   

Abstract

Elevation of intraocular pressure (IOP) in gas-containing eyes occurs not infrequently, and applanation tonometry in eyes with epithelial irregularities is not accurate. The pneumotonometer and TonoPen (Oculab, La Jolla, Calif) are alternative tonometers for use in these eyes, yet the accuracy of determining IOP with the Tono-Pen has not been determined manometrically. We performed a clinical and manometric study comparing the Tono-Pen with the pneumotonometer in gasfilled vitrectomized eyes. In our clinical study, we measured IOP in 50 eyes of 50 patients with corneal irregularities following vitrectomy and air/gas-fluid exchange. Tono-Pen measurements were highly correlated with those of the pneumotonometer. However, there was a mean difference of 1.4 mm Hg between Tono-Pen and pneumotonometer IOP readings. A larger percentage of Tono-Pen readings were lower than those of the pneumotonometer as IOP levels increased. To assess the accuracy of these tonometers, we compared manometric readings via an indwelling catheter with Tono-Pen and pneumotonometer IOP readings in 11 eye bank eyes following a lensectomy, vitrectomy, and air-fluid exchange. Overall, Tono-Pen and pneumotonometer readings were highly correlated with those of the manometer. However, both machines showed a significant underestimation of IOP at pressures greater than or equal to 30 mm Hg; pneumotonometer and Tono-Pen readings averaged 10.2 and 12.1 mm Hg lower, respectively, than those of the manometer. We conclude that both the pneumotonometer and the Tono-Pen underestimate IOP at pressures greater than or equal to 30 mm Hg.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2334326     DOI: 10.1001/archopht.1990.01070070070037

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  4 in total

1.  The use of topical aqueous suppressants in the prevention of postoperative intraocular pressure elevation following pars plana vitrectomy with long-acting gas tamponade.

Authors:  R A Mittra; J S Pollack; S Dev; D P Han; W F Mieler; T B Connor
Journal:  Trans Am Ophthalmol Soc       Date:  1998

2.  Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer.

Authors:  A Midelfart; A Wigers
Journal:  Br J Ophthalmol       Date:  1994-12       Impact factor: 4.638

Review 3.  Glaucoma management after vitreoretinal surgeries.

Authors:  Helen L Kornmann; Steven J Gedde
Journal:  Curr Opin Ophthalmol       Date:  2016-03       Impact factor: 3.761

4.  Glaucoma associated with the management of rhegmatogenous retinal detachment.

Authors:  George Mangouritsas; Spyridon Mourtzoukos; Dimitra M Portaliou; Vassilios I Georgopoulos; Anastasia Dimopoulou; Elias Feretis
Journal:  Clin Ophthalmol       Date:  2013-04-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.