Literature DB >> 23339094

Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge.

Stamatios Lerakis1, Salim S Hayek, Pamela S Douglas.   

Abstract

Entities:  

Mesh:

Year:  2013        PMID: 23339094     DOI: 10.1161/CIRCULATIONAHA.112.142000

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


× No keyword cloud information.
  45 in total

1.  Image-based immersed boundary model of the aortic root.

Authors:  Ali Hasan; Ebrahim M Kolahdouz; Andinet Enquobahrie; Thomas G Caranasos; John P Vavalle; Boyce E Griffith
Journal:  Med Eng Phys       Date:  2017-08-02       Impact factor: 2.242

Review 2.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

3.  In Vitro and Ex Vivo Hemodynamic Testing of an Innovative Occluder for Paravalvular Leak After Transcather Aortic Valve Implantation.

Authors:  Paolo Peruzzo; Gaetano Burriesci; Francesca Maria Susin; Andrea Colli
Journal:  J Cardiovasc Transl Res       Date:  2019-07-30       Impact factor: 4.132

4.  Valve hemodynamic performance and myocardial strain after implantation of a third-generation, balloon-expandable, transcatheter aortic valve.

Authors:  Sara Fernandez-Santos; Alexis Théron; Philippe Pibarot; Frédéric Collart; Martine Gilard; Marina Urena; Tomas Hovorka; Philipp Kahlert; José Luis Zamorano Gomez
Journal:  Cardiol J       Date:  2019-05-20       Impact factor: 2.737

5.  Lotus-in-Evolut R transcatheter aortic valve implantation for severe paravalvular leak.

Authors:  Shabnam Rashid; Daniel J Blackman; Christopher Malkin
Journal:  J Cardiol Cases       Date:  2016-06-09

Review 6.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

7.  The hemodynamic effects of acute aortic regurgitation into a stiffened left ventricle resulting from chronic aortic stenosis.

Authors:  Ikechukwu Okafor; Vrishank Raghav; Prem Midha; Gautam Kumar; Ajit Yoganathan
Journal:  Am J Physiol Heart Circ Physiol       Date:  2016-04-22       Impact factor: 4.733

8.  Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.

Authors:  Dayimi Kaya; Zulkif Tanriverdi; Huseyin Dursun; Tugce Colluoglu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-09       Impact factor: 2.357

Review 9.  How to Image and Manage Prosthesis-Related Complications After Transcatheter Aortic Valve Replacement.

Authors:  Nina C Wunderlich; Jörg Honold; Martin J Swaans; Robert J Siegel
Journal:  Curr Cardiol Rep       Date:  2021-07-01       Impact factor: 2.931

Review 10.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.