Literature DB >> 23338108

Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats.

Olavo Ribeiro Rodrigues1, Hélio Minamoto, Mauro Canzian, Aristides Tadeu Correia, Fabio Biscegli Jatene.   

Abstract

PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats.
METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen.
RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups.
CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23338108     DOI: 10.1590/s0102-86502013000100003

Source DB:  PubMed          Journal:  Acta Cir Bras        ISSN: 0102-8650            Impact factor:   1.388


  2 in total

1.  Management of tracheobronchial obstruction in infants using metallic stents: long-term outcome.

Authors:  Ling Leung; Patrick Ho Yu Chung; Kenneth Kak Yuen Wong; Paul Kwong Hang Tam
Journal:  Pediatr Surg Int       Date:  2015-01-24       Impact factor: 1.827

2.  Comparison of three kinds of self-expandable metallic stents induced granulation tissue hyperplasia in the rabbit trachea.

Authors:  Yahua Li; Mengde Li; Xiaofeng Wang; Yuhui Wang; Chang Li; Yanan Zhao; Zhaonan Li; Jianjian Chen; Jing Li; Kewei Ren; Zongming Li; Jianzhuang Ren; Xinwei Han; Qian Li
Journal:  Sci Rep       Date:  2021-11-30       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.