Literature DB >> 23336391

Live/Real time three-dimensional transesophageal echocardiography in percutaneous closure of atrial septal defects.

Maneesha Bhaya1, Ferit Onur Mutluer, Edward Mahan, Luke Mahan, Ming C Hsiung, Wei-Hsian Yin, Jeng Wei, Shen-Kou Tsai, Guang-Yu Zhao, Wei-Hsian Yin, Manish Pradhan, Rajesh Beniwal, Deepak Joshi, Fatemeh Nabavizadeh, Amitoj Singh, Navin C Nanda.   

Abstract

OBJECTIVES: This study assessed the ability of live/real time three-dimensional transesophageal echocardiography (3DTEE) in measuring (1) atrial septal defect (ASD) maximum dimension, area, and adjacent rim size, (2) ASD occluder left and right atrial disk size, (3) length of contact between the left atrial (LA) disk and the aorta, and in (4) assessing device related complications such as residual shunt, device embolization, and device encroachment upon adjacent cardiac structures.
MATERIALS AND METHODS: 3DTEE images acquired during percutaneous ASD closure by the Amplatzer Septal Occluder in 15 adult patients were retrospectively analyzed. Offline analysis was done using both the Philips 5500 ultrasound system and Philips QLAB software. 3D color flow Doppler images were used to assess residual ASD shunting.
RESULTS: The Philips 5500 and Philips QLAB measurements correlated well for ASD maximum dimension and area measurements. The Philips QLAB 3DTEE disk size measurements also correlated well with the manufacturer obtained sizes. The aortic rim was deficient in 7 of the 15 patients, and the mean ASD occluder device size was 4 mm greater than the mean ASD maximum dimension. The LA occluder disk was in contact with the aorta throughout the cardiac cycle in 12 of the 15 patients, and the LA occluder disk size correlated significantly with the contact length with the aorta.
CONCLUSION: Most of the patients demonstrated contact between the LA occluder disk and the aorta throughout the cardiac cycle. 3DTEE may be useful in identifying patients at greater risk for aortic erosion.
© 2013, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2013        PMID: 23336391     DOI: 10.1111/echo.12106

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  9 in total

Review 1.  Interventional imaging: the role of echocardiography.

Authors:  Dimitrios Maragiannis; Stephen H Little
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

Review 2.  [Imaging in structural heart disease : Impact on interventional therapy].

Authors:  A Schmermund; J Eckert; S N Schelle; H Eggebrecht
Journal:  Herz       Date:  2016-11       Impact factor: 1.443

3.  How to Size ASDs for Percutaneous Closure.

Authors:  Isabelle Boon; Katrien Vertongen; Bernard P Paelinck; Laurent Demulier; An Van Berendoncks; Catherine De Maeyer; Fabienne Marchau; Joseph Panzer; Kristof Vandekerckhove; Daniel De Wolf
Journal:  Pediatr Cardiol       Date:  2017-09-27       Impact factor: 1.655

Review 4.  Innovation in 3D Echocardiographic Imaging.

Authors:  Pei-Ni Jone; Nee Khoo
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-01-19

5.  Utility of balloon assisted technique in trans catheter closure of very large (≥35 mm) atrial septal defects.

Authors:  Ajith Ananthakrishna Pillai; Vidhyakar Rangaswamy Balasubramanian; Raja Selvaraj; Maheshkumar Saktheeswaran; Santhosh Satheesh; Balachander Jayaraman
Journal:  Cardiovasc Diagn Ther       Date:  2014-02

6.  Balloon occlusive diameter of non-circular atrial septal defects in transcatheter closure with amplatzer septal occluder.

Authors:  Kwang Hoon Kim; Jinyoung Song; I-Seok Kang; Sung-A Chang; June Huh; Seung Woo Park
Journal:  Korean Circ J       Date:  2013-10-30       Impact factor: 3.243

Review 7.  General Concepts in Adult Congenital Heart Disease.

Authors:  Ferit Onur Mutluer; Alpay Çeliker
Journal:  Balkan Med J       Date:  2018-01-20       Impact factor: 2.021

8.  Catheter-based closure of a large atrial septal defect with inferior rim deficiency using pulmonary vein slide-out assisted implantation technique: a case report.

Authors:  Salvatore Evola; Oreste Fabio Triolo; Giuseppina Novo; Eustaquio Maria Onorato
Journal:  Eur Heart J Case Rep       Date:  2021-02-08

Review 9.  Device closure of secundum atrial septal defect's and the risk of cardiac erosion.

Authors:  J D R Thomson; S A Qureshi
Journal:  Echo Res Pract       Date:  2015-09-02
  9 in total