Literature DB >> 23333228

Development of an amperometric screen-printed galactose biosensor for serum analysis.

Prosper Kanyong1, Roy M Pemberton, Simon K Jackson, John P Hart.   

Abstract

The development of a disposable amperometric biosensor for the measurement of circulating galactose in serum is described. The biosensor comprises a screen-printed carbon electrode (SPCE), incorporating the electrocatalyst cobalt phthalocyanine (CoPC), which is covered by a permselective cellulose acetate (CA) membrane and a layer of immobilized galactose oxidase (GALOX). The optimal response of the biosensor, designated as GALOX-CA-CoPC-SPCE, was obtained by systematically examining the effects of enzyme loading, temperature, pH, and buffer strength. The optimal performance of the biosensor occurred with 2U of GALOX, at 35°C, using 50mM phosphate buffer solution (pH 7.0). The sensitivity was 7.00μAmM(-1)cm(-2) and the linear range from 0.1 to 25mM with a calculated limit of detection (LOD) of 0.02mM; this concentration range and LOD are appropriate to diagnose galactosemia, i.e., concentrations >1.1mM in infants. When the biosensor was used in conjunction with amperometry in stirred solution for the analysis of serum, the precision values obtained on unspiked (endogenous level of 0.153mM) and spiked serum (1mM added) (n=6) were 1.10% and 0.11%, respectively, with a calculated recovery of 99.9%.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23333228     DOI: 10.1016/j.ab.2013.01.006

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  6 in total

1.  Structure of the Reduced Copper Active Site in Preprocessed Galactose Oxidase: Ligand Tuning for One-Electron O2 Activation in Cofactor Biogenesis.

Authors:  Ryan E Cowley; Jordi Cirera; Munzarin F Qayyum; Dalia Rokhsana; Britt Hedman; Keith O Hodgson; David M Dooley; Edward I Solomon
Journal:  J Am Chem Soc       Date:  2016-09-28       Impact factor: 15.419

2.  Expression, purification, and characterization of galactose oxidase of Fusarium sambucinum in E. coli.

Authors:  Regina Paukner; Petra Staudigl; Withu Choosri; Dietmar Haltrich; Christian Leitner
Journal:  Protein Expr Purif       Date:  2014-12-24       Impact factor: 1.650

Review 3.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids.

Authors:  Gaia Rocchitta; Angela Spanu; Sergio Babudieri; Gavinella Latte; Giordano Madeddu; Grazia Galleri; Susanna Nuvoli; Paola Bagella; Maria Ilaria Demartis; Vito Fiore; Roberto Manetti; Pier Andrea Serra
Journal:  Sensors (Basel)       Date:  2016-05-30       Impact factor: 3.576

4.  A Disposable Amperometric Sensor Based on High-Performance PEDOT:PSS/Ionic Liquid Nanocomposite Thin Film-Modified Screen-Printed Electrode for the Analysis of Catechol in Natural Water Samples.

Authors:  Francis D Krampa; Yaw Aniweh; Gordon A Awandare; Prosper Kanyong
Journal:  Sensors (Basel)       Date:  2017-07-26       Impact factor: 3.576

Review 5.  Recent Advances in the Fabrication and Application of Screen-Printed Electrochemical (Bio)Sensors Based on Carbon Materials for Biomedical, Agri-Food and Environmental Analyses.

Authors:  Gareth Hughes; Kelly Westmacott; Kevin C Honeychurch; Adrian Crew; Roy M Pemberton; John P Hart
Journal:  Biosensors (Basel)       Date:  2016-09-28

Review 6.  Enzyme-based amperometric galactose biosensors: a review.

Authors:  Prosper Kanyong; Francis D Krampa; Yaw Aniweh; Gordon A Awandare
Journal:  Mikrochim Acta       Date:  2017-08-25       Impact factor: 5.833

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.