Literature DB >> 23329872

Utility of the NavX® Electroanatomic Mapping System for Permanent Pacemaker Implantation in a Pregnant Patient with Chagas Disease.

Alejandro Velasco1, Victor Manuel Velasco, Fernando Rosas, Cihan Cevik, Carlos A Morillo.   

Abstract

Chagas disease is a highly prevalent zoonosis in Mexico, Central, and South America. Early cardiac involvement is one of the most serious complications of this disease, and conduction disturbances may occur at an early age. We describe a young pregnant woman with Chagas disease and a high degree atrioventricular block, who required implantation of a permanent dual chamber pacemaker. Using an electroanatomic navigation EnSite NavX® system the pacemaker was successfully implanted with minimal fluoroscopic exposure. This case demonstrates the safety and feasibility of using an electroanatomic navigation system to guide permanent pacemaker implantation minimizing x-ray exposure in pregnant patients.

Entities:  

Keywords:  Chagas disease; Electroanatomic Navigation; Heart Block; Non-fluoroscopic imaging; Permanent Cardiac Pacemaker; Pregnancy

Year:  2013        PMID: 23329872      PMCID: PMC3539398          DOI: 10.1016/s0972-6292(16)30586-1

Source DB:  PubMed          Journal:  Indian Pacing Electrophysiol J        ISSN: 0972-6292


  5 in total

1.  Implantation of permanent dual chamber pacemaker in a pregnant woman by transesophageal echocardiographic guidance.

Authors:  D Antonelli; L Bloch; T Rosenfeld
Journal:  Pacing Clin Electrophysiol       Date:  1999-03       Impact factor: 1.976

2.  Successful pregnancy outcome with cardiac pacemaker after complete heart block.

Authors:  J B Sharma; M Malhotra; P Pundir
Journal:  Int J Gynaecol Obstet       Date:  2000-02       Impact factor: 3.561

Review 3.  Chagas disease.

Authors:  Anis Rassi; Anis Rassi; José Antonio Marin-Neto
Journal:  Lancet       Date:  2010-04-17       Impact factor: 79.321

4.  Atrioventricular node ablation and permanent ventricular pacemaker implantation without fluoroscopy: use of an electroanatomic navigation system.

Authors:  Ricardo Ruiz-Granell; Salvador Morell-Cabedo; Angel Ferrero-De-Loma; Roberto García-Civera
Journal:  J Cardiovasc Electrophysiol       Date:  2005-07

5.  Implantation of single-lead atrioventricular permanent pacemakers guided by electroanatomic navigation without the use of fluoroscopy.

Authors:  Ricardo Ruiz-Granell; Angel Ferrero; Salvador Morell-Cabedo; Angel Martinez-Brotons; Vicente Bertomeu; Angel Llacer; Roberto García-Civera
Journal:  Europace       Date:  2008-06-03       Impact factor: 5.214

  5 in total
  8 in total

1.  Cardiac Interventions in Pregnant Patients without Fluoroscopy.

Authors:  Volkan Tuzcu; Enes Elvin Gul; Abdullah Erdem; Hacer Kamali; Turkay Saritas; Cem Karadeniz; Celal Akdeniz
Journal:  Pediatr Cardiol       Date:  2015-05-07       Impact factor: 1.655

2.  Chagas heart disease: A contemporary review.

Authors:  Alejandro Velasco; Carlos A Morillo
Journal:  J Nucl Cardiol       Date:  2018-07-18       Impact factor: 5.952

Review 3.  Three-dimensional mapping in cardiac implantable electronic device - a feasible and effective alternative to fluoroscopy.

Authors:  Xiaozhen Ge; Mengna Chen; Zhongxin Sha; Junmeng Zhang
Journal:  J Interv Card Electrophysiol       Date:  2022-07-09       Impact factor: 1.900

4.  Response to Letter: "Use of Electroanatomic Mapping Systems beyond Electrophysiologic Studies".

Authors:  Alejandro Velasco; Victor Manuel Velasco; Fernando Rosas; Cihan Cevik; Carlos A Morillo
Journal:  Indian Pacing Electrophysiol J       Date:  2013-08-01

5.  Use of Electroanatomic Mapping Systems beyond Electrophysiologic Studies.

Authors:  Serkan Cay
Journal:  Indian Pacing Electrophysiol J       Date:  2013-08-01

6.  Implantation of a dual-chamber permanent pacemaker in a pregnant patient guided by intracardiac echocardiography and electroanatomic mapping.

Authors:  Kelvin C M Chua; Eric T S Lim; Daniel T T Chong; Boon Yew Tan; Kah Leng Ho; Chi Keong Ching
Journal:  HeartRhythm Case Rep       Date:  2017-09-29

7.  Near-zero fluoroscopy implantation of dual-chamber pacemaker in pregnancy using electroanatomic mapping.

Authors:  Jason Payne; Monica Lo; Hakan Paydak; Waddah Maskoun
Journal:  HeartRhythm Case Rep       Date:  2017-01-27

8.  Aegrescit medendo: orthopedic disability in electrophysiology - call for fluoroscopy elimination-review and commentary.

Authors:  Donald S Rubenstein; Benjamin B Holmes; Joseph A Manfredi; Matthew S McKillop; Peter C Netzler; Chad C Ward
Journal:  J Interv Card Electrophysiol       Date:  2022-03-08       Impact factor: 1.759

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.