Literature DB >> 18523029

Implantation of single-lead atrioventricular permanent pacemakers guided by electroanatomic navigation without the use of fluoroscopy.

Ricardo Ruiz-Granell1, Angel Ferrero, Salvador Morell-Cabedo, Angel Martinez-Brotons, Vicente Bertomeu, Angel Llacer, Roberto García-Civera.   

Abstract

AIMS: Fluoroscopy is the standard and almost unique tool used for cardiac imaging during permanent pacemaker implantation, and its use implies exposure of patients and operators to radiation. The usefulness for this purpose of electroanatomic systems not based on fluoroscopy is unknown. Our aim was to study the feasibility of implanting single-lead VDD pacemakers without the use of fluoroscopy. METHODS AND
RESULTS: EnSite NavX, a catheter navigation tool based on the creation of a voltage gradient across the thorax of the patient, was used as an exclusive imaging tool during the implantation of single-lead atrioventricular (VDD) permanent pacemakers in 15 consecutive patients with atrioventricular block and normal sinus node function. A retrospective series of 15 consecutive patients in whom VDD pacemakers were implanted under fluoroscopic guidance was used as a control group. The pacemaker could be implanted in all patients. Time spent to obtain the right ventricle anatomy was 10.1 +/- 5.4 min and time to place the lead in an adequate position was 10.1 +/- 7.8 min. Total implant time was 59.3 +/- 15.6 min (51.5 +/- 12.3 min in the control group; P = 0.14). In one patient, a short pulse of radioscopy was needed for a correct catheterization of the subclavian vein. No complications were observed during the procedure. One lead dislodgement that required re-operation was detected 24 h after implantation. At 3 months follow-up, all pacemakers were functioning properly, with adequate pacing and sensing thresholds.
CONCLUSION: Electroanatomic navigation systems such as NavX can be used for cardiac imaging during single-lead atrioventricular pacemaker implantation as a reliable and safe alternative to fluoroscopy.

Entities:  

Mesh:

Year:  2008        PMID: 18523029     DOI: 10.1093/europace/eun139

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  14 in total

1.  Accurate guidance of a catheter by ultrasound imaging and identification of a catheter tip by pulsed-wave Doppler.

Authors:  Eileen M McMahon; Panupong Jiamsripong; Minako Katayama; Hari P Chaliki; Mostafa Fatemi; Marek Belohlavek
Journal:  Pacing Clin Electrophysiol       Date:  2011-11-06       Impact factor: 1.976

Review 2.  Routine Implant of Biventricular Devices Guided by an Electroanatomic Mapping System - Ready for Prime-Time?

Authors:  Kim H Chan; Peter A Santucci
Journal:  J Atr Fibrillation       Date:  2015-12-31

3.  Cardiac Interventions in Pregnant Patients without Fluoroscopy.

Authors:  Volkan Tuzcu; Enes Elvin Gul; Abdullah Erdem; Hacer Kamali; Turkay Saritas; Cem Karadeniz; Celal Akdeniz
Journal:  Pediatr Cardiol       Date:  2015-05-07       Impact factor: 1.655

Review 4.  Three-dimensional mapping in cardiac implantable electronic device - a feasible and effective alternative to fluoroscopy.

Authors:  Xiaozhen Ge; Mengna Chen; Zhongxin Sha; Junmeng Zhang
Journal:  J Interv Card Electrophysiol       Date:  2022-07-09       Impact factor: 1.900

5.  Utility of the NavX® Electroanatomic Mapping System for Permanent Pacemaker Implantation in a Pregnant Patient with Chagas Disease.

Authors:  Alejandro Velasco; Victor Manuel Velasco; Fernando Rosas; Cihan Cevik; Carlos A Morillo
Journal:  Indian Pacing Electrophysiol J       Date:  2013-01-01

6.  Implantation of a biventricular implantable cardioverter-defibrillator guided by an electroanatomic mapping system.

Authors:  Maurizio Del Greco; Massimiliano Marini; Roberto Bonmassari
Journal:  Europace       Date:  2011-08-18       Impact factor: 5.214

7.  Implantation of a dual-chamber permanent pacemaker in a pregnant patient guided by intracardiac echocardiography and electroanatomic mapping.

Authors:  Kelvin C M Chua; Eric T S Lim; Daniel T T Chong; Boon Yew Tan; Kah Leng Ho; Chi Keong Ching
Journal:  HeartRhythm Case Rep       Date:  2017-09-29

8.  Electroanatomical mapping- and CT scan image integration-guided pacing lead implantation: A case series and review of the recent literature.

Authors:  Jens Kristensen; Mads Brix Kronborg; Christian Gerdes; Jens Cosedis Nielsen
Journal:  Heart Rhythm O2       Date:  2020-10-28

9.  Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy.

Authors:  Fabio Quartieri; Daniele Giacopelli; Matteo Iori; Nicola Bottoni
Journal:  Indian Pacing Electrophysiol J       Date:  2016-08-20

10.  Reconstruction left atrium and isolation pulmonary veins of paroxysmal atrial fibrillation using single contact force catheter with zero x-ray exposure: A CONSORT Study.

Authors:  Jian Qiang Zhang; Rong Hui Yu; Jia Bing Liang; De Yong Long; Cai Hua Sang; Chang Sheng Ma; Jian Zeng Dong
Journal:  Medicine (Baltimore)       Date:  2017-10       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.