Literature DB >> 2332061

The influence of chamber characteristics on the reliability of sperm concentration and movement measurements obtained by manual and videomicrographic analysis.

K A Ginsburg1, D R Armant.   

Abstract

To assess the influence of chamber design and depth on the accuracy and precision of sperm measurements, manual counting of a standardized latex bead solution and automated sperm motility measurements were made using a Makler chamber (Sefi Medical Industries, Haifa, Israel), Neubauer hemocytometer (American Optical Company, Buffalo, NY), and a new, disposable device (Micro-Cell; Cyto Fluidics, Inc., Silver Spring, MD). Bead counts obtained with the Micro-Cell chamber or hemocytometer were not statistically different from those determined by electronic particle counting, whereas Makler chamber counts were 62% higher. Makler counts had a significantly higher standard deviation, suggesting that counts made with this device are less reproducible. Analyzing live sperm samples, the percentage of motile sperm determined using Micro-Cell and Makler chambers were similar. However, significant differences in sperm concentration and mean velocity were found. The Micro-Cell disposable chamber provided consistent and accurate data on sperm concentration, percent motility, and mean velocity. These differences in sperm measurements emphasize the importance of sampling chamber characteristics on data reliability.

Mesh:

Year:  1990        PMID: 2332061     DOI: 10.1016/s0015-0282(16)53526-2

Source DB:  PubMed          Journal:  Fertil Steril        ISSN: 0015-0282            Impact factor:   7.329


  7 in total

1.  Can Westgard Quality Control Rules determine the suitability of frozen sperm pellets as a control material for computer assisted semen analyzers?

Authors:  Jane E Johnson; Dawn W Blackhurt; William R Boone
Journal:  J Assist Reprod Genet       Date:  2003-01       Impact factor: 3.412

2.  Does seasonality alter intrauterine insemination outcomes: a 5-year study.

Authors:  J Glenn Proctor; Dawn W Blackhurst; William R Boone
Journal:  J Assist Reprod Genet       Date:  2004-07       Impact factor: 3.412

3.  Comparative study of Sperm Motility Analysis System and conventional microscopic semen analysis.

Authors:  Kazuhiko Komori; Akira Tsujimura; Sumio Ishijima; Phanu Tanjapatkul; Kazutoshi Fujita; Yasuhiro Matsuoka; Tetsuya Takao; Yasushi Miyagawa; Shingo Takada; Akihiko Okuyama
Journal:  Reprod Med Biol       Date:  2006-08-09

4.  Evaluating the accuracy of different sperm counting chambers by performing strict counts of photographed beads.

Authors:  E Shiran; J Stoller; Z Blumenfeld; P D Feigin; A Makler
Journal:  J Assist Reprod Genet       Date:  1995-08       Impact factor: 3.412

5.  Semen analysis and sperm function tests: How much to test?

Authors:  S S Vasan
Journal:  Indian J Urol       Date:  2011-01

Review 6.  Current updates on laboratory techniques for the diagnosis of male reproductive failure.

Authors:  Suresh C Sikka; Wayne J G Hellstrom
Journal:  Asian J Androl       Date:  2016 May-Jun       Impact factor: 3.285

Review 7.  The possible effects of environmental estrogen disrupters on reproductive health.

Authors:  H Fisch; G Hyun; R Golden
Journal:  Curr Urol Rep       Date:  2000-12       Impact factor: 2.862

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.