Literature DB >> 23313622

In-line monitoring of the drug content of powder mixtures and tablets by near-infrared spectroscopy during the continuous direct compression tableting process.

Kristiina Järvinen1, Wolfgang Hoehe, Maiju Järvinen, Sami Poutiainen, Mikko Juuti, Sven Borchert.   

Abstract

Continuous manufacturing methods offer economic and quality advantages when compared with batch manufacturing methods. In continuous manufacturing, one requires real time assurance of quality of product via the implementation of PAT tools. This study focuses on an in-line near-infrared (NIR) spectroscopic method for determining the drug content of powder mixtures and tablets during a continuous tableting process. Tablets consisting of acetaminophen (20-30%), lactose (69.07-78.93%) and magnesium stearate (0.93-1.07%) were prepared in a continuous direct compression line that consisted of two loss-in-weight feeders, one for acetaminophen and one for premixed lactose and magnesium stearate, and a continuous mixer followed by a rotary tablet press. NIR spectroscopy was applied to the continuous mixer and tablet press to perform a 100% product check at full tableting speed. The UV-spectrophotometric method was used as an off-line reference method to determine the acetaminophen content in the samples. The powder mixture and tablet samples were taken during the process for the calibration of continuous mixer and tablet press, respectively. For the continuous mixer, model creation with the PLS method yielded R-Square and RMSEC (root mean square error of calibration) values of 0.975% and 0.56%, respectively. For the tablet press, the corresponding R-Square and RMSEC values were 0.943% and 0.75%, respectively. A test run demonstrated good predictability in the estimation of the API content in the powder mixtures and tablets during the continuous tableting process. For the continuous mixer and tablet press, the RMSEP (root mean square error of prediction) values were 0.96% and 1.37%, respectively. This study demonstrates that an NIR instrument capable of fast spectra acquisition can be a valuable tool for the in-line monitoring of the continuous mixing and tableting processes.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23313622     DOI: 10.1016/j.ejps.2012.12.032

Source DB:  PubMed          Journal:  Eur J Pharm Sci        ISSN: 0928-0987            Impact factor:   4.384


  7 in total

1.  Additive manufacturing of prototype elements with process interfaces for continuously operating manufacturing lines.

Authors:  Cosima Hirschberg; Mikkel Schmidt Larsen; Johan Peter Bøtker; Jukka Rantanen
Journal:  Asian J Pharm Sci       Date:  2018-05-23       Impact factor: 6.598

2.  Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring.

Authors:  Tibor Casian; Alexandru Gavan; Sonia Iurian; Alina Porfire; Valentin Toma; Rares Stiufiuc; Ioan Tomuta
Journal:  Molecules       Date:  2021-02-20       Impact factor: 4.411

3.  Continuous direct compression: Development of an empirical predictive model and challenges regarding PAT implementation.

Authors:  B Bekaert; B Van Snick; K Pandelaere; J Dhondt; G Di Pretoro; T De Beer; C Vervaet; V Vanhoorne
Journal:  Int J Pharm X       Date:  2021-12-25

Review 4.  Pharmaceutical application of multivariate modelling techniques: a review on the manufacturing of tablets.

Authors:  Guolin Shi; Longfei Lin; Yuling Liu; Gongsen Chen; Yuting Luo; Yanqiu Wu; Hui Li
Journal:  RSC Adv       Date:  2021-02-23       Impact factor: 3.361

Review 5.  Process Analytical Technology Tools for Monitoring Pharmaceutical Unit Operations: A Control Strategy for Continuous Process Verification.

Authors:  Eun Ji Kim; Ji Hyeon Kim; Min-Soo Kim; Seong Hoon Jeong; Du Hyung Choi
Journal:  Pharmaceutics       Date:  2021-06-21       Impact factor: 6.321

6.  On-line quantitative monitoring of liquid-liquid extraction of Lonicera japonica and Artemisia annua using near-infrared spectroscopy and chemometrics.

Authors:  Sha Wu; Ye Jin; Qian Liu; Qi-An Liu; Jianxiong Wu; Yu-An Bi; Zhengzhong Wang; Wei Xiao
Journal:  Pharmacogn Mag       Date:  2015 Jul-Sep       Impact factor: 1.085

7.  In-Depth Understanding of Granule Compression Behavior under Variable Raw Material and Processing Conditions.

Authors:  Tibor Casian; Sonia Iurian; Alexandru Gâvan; Alina Porfire; Anca Lucia Pop; Simona Crișan; Anda Maria Pușcaș; Ioan Tomuță
Journal:  Pharmaceutics       Date:  2022-01-12       Impact factor: 6.321

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.