Literature DB >> 23305358

Effect of implant angulation on attachment retention in mandibular two-implant overdentures: a clinical study.

Zaher Jabbour1, Olivier Fromentin, Claire Lassauzay, Samer Abi Nader, José A Correa, Jocelyne Feine, Rubens F de Albuquerque Junior.   

Abstract

PURPOSE: Attachment wear can affect the performance of mandibular two-implant overdentures (IODs). This prospective clinical study aimed to investigate the effect of interimplant angulation on the retention achieved by two attachment systems at different time points within 1 year of wearing IODs.
MATERIALS AND METHODS: Twenty-four patients (mean age = 73.2 years; standard deviation (SD) = 3.1) wearing IODs opposed by conventional maxillary complete dentures were randomly assigned to two groups in two-by-two crossover design. Retentive Anchor (RA) and Locator (LA) were installed in the IODs of both groups for 1 year, sequentially. Coronal and sagittal interimplant angulation were measured on posterior-anterior and lateral cephalometric radiographs. Retention was measured at baseline, 1 week, 3, 6, and 12 months postattachment installation. Data were analyzed using mixed models with α = 0.05.
RESULTS: Mean coronal and sagittal interimplant angulations were 4.6 (SD = 2.9) and 3.5 (SD = 2.6) degrees, respectively. Only with LAs a statistically significant decrease was found in retention (average 1.1 Newton; standard error = 0.38; p = .007) per 1 degree increased sagittal interimplant angulation.
CONCLUSIONS: Increased interimplant angulation appears to have higher impact on the retention of LA than of RA attachments. The effect of larger interimplant angulation on the loss of attachment retention and its clinical implications should be further assessed.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  implant attachment; interimplant angulation; mandibular two-implant overdenture; retention

Mesh:

Year:  2013        PMID: 23305358     DOI: 10.1111/cid.12030

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  6 in total

1.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

2.  Single-implant overdentures retained by the Novaloc attachment system: study protocol for a mixed-methods randomized cross-over trial.

Authors:  Raphael F de Souza; Christophe Bedos; Shahrokh Esfandiari; Nicholas M Makhoul; Didem Dagdeviren; Samer Abi Nader; Areej A Jabbar; Jocelyne S Feine
Journal:  Trials       Date:  2018-04-23       Impact factor: 2.279

3.  Development of a dental handpiece angle correction device.

Authors:  Yoon Nam; Mi Young Eo; Soung Min Kim
Journal:  Biomed Eng Online       Date:  2018-11-26       Impact factor: 2.819

Review 4.  Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Raphaël Wakam; Aurélie Benoit; Kwamivi Bernardin Mawussi; Caroline Gorin
Journal:  Materials (Basel)       Date:  2022-03-04       Impact factor: 3.623

5.  Using Different Low-Profile Abutments for Assisting Mandibular Implant Overdenture: A Split-Mouth Study.

Authors:  Ahmed K Khalifa; Mohammad Mahmoud Alokda; Mohamed Moustafa Said
Journal:  Int J Dent       Date:  2022-04-09

6.  In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®.

Authors:  Nieves Mínguez-Tomás; Jorge Alonso-Pérez-Barquero; Lucía Fernández-Estevan; Ángel Vicente-Escuder; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2018-07-01
  6 in total