Literature DB >> 23299866

What makes a BIA equation unique? Validity of eight-electrode multifrequency BIA to estimate body composition in a healthy adult population.

A Bosy-Westphal1, B Schautz, W Later, J J Kehayias, D Gallagher, M J Müller.   

Abstract

BACKGROUND/
OBJECTIVES: The validity of bioelectrical impedance analysis (BIA) for body composition analysis is limited by assumptions relating to body shape. Improvement in BIA technology could overcome these limitations and reduce the population specificity of the BIA algorithm. SUBJECTS/
METHODS: BIA equations for the prediction of fat-free mass (FFM), total body water (TBW) and extracellular water (ECW) were generated from data obtained on 124 Caucasians (body mass index 18.5-35 kg/m(2)) using a four-compartment model and dilution techniques as references. The algorithms were validated in an independent multiethnic population (n=130). The validity of BIA results was compared (i) between ethnic groups and (ii) with results from the four-compartment model and two-compartment methods (air-displacement plethysmography, dual-energy X-ray absorptiometry and deuterium dilution).
RESULTS: Indices were developed from segmental R and Xc values to represent the relative contribution of trunk and limbs to total body conductivity. The coefficient of determination for all prediction equations was high (R(2): 0.94 for ECW, 0.98 for FFM and 0.98 for TBW) and root mean square error was low (1.9 kg for FFM, 0.8 l for ECW and 1.3 kg for TBW). The bias between BIA results and different reference methods was not statistically different between Afro-American, Hispanic, Asian or Caucasian populations and showed a similar difference (-0.2-0.2 kg FFM) when compared with the bias between different two-compartment reference methods (-0.2-0.3 kg FFM).
CONCLUSIONS: An eight-electrode, segmental multifrequency BIA is a valid tool to estimate body composition in healthy euvolemic adults compared with the validity and precision of other two-compartment reference methods. Population specificity is of minor importance when compared with discrepancies between different reference methods.

Entities:  

Mesh:

Year:  2013        PMID: 23299866     DOI: 10.1038/ejcn.2012.160

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


  63 in total

1.  Comparison of segmental body composition estimated by bioelectrical impedance analysis and dual-energy X-ray absorptiometry.

Authors:  Brooks C Wingo; Valene Garr Barry; Amy C Ellis; Barbara A Gower
Journal:  Clin Nutr ESPEN       Date:  2018-09-11

2.  Cross-sectional and longitudinal agreement between two multifrequency bioimpedance devices for resistance, reactance, and phase angle values.

Authors:  Grant M Tinsley; M Lane Moore; Analiza M Silva; Luis B Sardinha
Journal:  Eur J Clin Nutr       Date:  2019-08-27       Impact factor: 4.016

3.  Longitudinal agreement of four bioimpedance analyzers for detecting changes in raw bioimpedance during purposeful weight gain with resistance training.

Authors:  Matthew T Stratton; Robert W Smith; Patrick S Harty; Christian Rodriguez; Baylor A Johnson; Jacob R Dellinger; Abegale D Williams; Sarah J White; Marqui L Benavides; Grant M Tinsley
Journal:  Eur J Clin Nutr       Date:  2021-03-16       Impact factor: 4.016

4.  Electromyographic amplitude versus torque relationships are different in young versus postmenopausal females and are related to muscle mass after controlling for bodyweight.

Authors:  Nile F Banks; Emily M Rogers; Nathaniel D M Jenkins
Journal:  Eur J Appl Physiol       Date:  2020-10-29       Impact factor: 3.078

5.  Derivation and validation of simple anthropometric equations to predict adipose tissue mass and total fat mass with MRI as the reference method.

Authors:  Yasmin Y Al-Gindan; Catherine R Hankey; Lindsay Govan; Dympna Gallagher; Steven B Heymsfield; Michael E J Lean
Journal:  Br J Nutr       Date:  2015-10-05       Impact factor: 3.718

6.  Phase angle is not associated with fatigue in cancer patients: the hydration impact.

Authors:  Tatyanne L N Gomes; Jéssika D P Soares; Thaís C Borges; Claude Pichard; Gustavo D Pimentel
Journal:  Eur J Clin Nutr       Date:  2020-03-02       Impact factor: 4.016

7.  Effects of procedure, upright equilibrium time, sex and BMI on the precision of body fluid measurements using bioelectrical impedance analysis.

Authors:  S Thurlow; G Taylor-Covill; P Sahota; B Oldroyd; K Hind
Journal:  Eur J Clin Nutr       Date:  2017-07-19       Impact factor: 4.016

8.  Long-Term Body Composition Changes in Women Following Roux-en-Y Gastric Bypass Surgery.

Authors:  Abigail J Cole; Adam J Kuchnia; Lauren M Beckman; Cyrus Jahansouz; Jennifer R Mager; Shalamar D Sibley; Carrie P Earthman
Journal:  JPEN J Parenter Enteral Nutr       Date:  2016-02-02       Impact factor: 4.016

9.  Associations Among Maternal Adiposity, Insulin, and Adipokines in Circulation and Human Milk.

Authors:  Camille R Schneider-Worthington; Jessica S Bahorski; David A Fields; Barbara A Gower; José R Fernández; Paula C Chandler-Laney
Journal:  J Hum Lact       Date:  2020-10-09       Impact factor: 2.219

10.  Derivation and validation of simple equations to predict total muscle mass from simple anthropometric and demographic data.

Authors:  Yasmin Y Al-Gindan; Catherine Hankey; Lindsay Govan; Dympna Gallagher; Steven B Heymsfield; Michael E J Lean
Journal:  Am J Clin Nutr       Date:  2014-08-13       Impact factor: 7.045

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.