Three-dimensional optoacoustic tomography using a conventional ultrasound linear detector array: whole-body tomographic system for small animals.

Jerome Gateau1, Miguel Angel Araque Caballero, Alexander Dima, Vasilis Ntziachristos.   

Abstract

PURPOSE: Optoacoustic imaging relies on the detection of ultrasonic waves induced by laser pulse excitations to map optical absorption in biological tissue. A tomographic geometry employing a conventional ultrasound linear detector array for volumetric optoacoustic imaging is reported. The geometry is based on a translate-rotate scanning motion of the detector array, and capitalizes on the geometrical characteristics of the transducer assembly to provide a large solid angular detection aperture. A system for three-dimensional whole-body optoacoustic tomography of small animals is implemented.
METHODS: The detection geometry was tested using a 128-element linear array (5.0∕7.0 MHz, Acuson L7, Siemens), moved by steps with a rotation∕translation stage assembly. Translation and rotation range of 13.5 mm and 180°, respectively, were implemented. Optoacoustic emissions were induced in tissue-mimicking phantoms and ex vivo mice using a pulsed laser operating in the near-IR spectral range at 760 nm. Volumetric images were formed using a filtered backprojection algorithm.
RESULTS: The resolution of the optoacoustic tomography system was measured to be better than 130 μm in-plane and 330 μm in elevation (full width half maximum), and to be homogenous along a 15 mm diameter cross section due to the translate-rotate scanning geometry. Whole-body volumetric optoacoustic images of mice were performed ex vivo, and imaged organs and blood vessels through the intact abdominal and head regions were correlated to the mouse anatomy.
CONCLUSIONS: Overall, the feasibility of three-dimensional and high-resolution whole-body optoacoustic imaging of small animal using a conventional linear array was demonstrated. Furthermore, the scanning geometry may be used for other linear arrays and is therefore expected to be of great interest for optoacoustic tomography at macroscopic and mesoscopic scale. Specifically, conventional detector arrays with higher central frequencies may be investigated.

Entities:  

Mesh:

Year:  2013        PMID: 23298121     DOI: 10.1118/1.4770292

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Optical mesoscopy without the scatter: broadband multispectral optoacoustic mesoscopy.

Authors:  Andrei Chekkoury; Jérôme Gateau; Wouter Driessen; Panagiotis Symvoulidis; Nicolas Bézière; Annette Feuchtinger; Axel Walch; Vasilis Ntziachristos
Journal:  Biomed Opt Express       Date:  2015-07-31       Impact factor: 3.732

Review 2.  [Optoacoustic imaging].

Authors:  M Fournelle; S Tretbar
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

3.  Improving limited-view photoacoustic tomography with an acoustic reflector.

Authors:  Bin Huang; Jun Xia; Konstantin Maslov; Lihong V Wang
Journal:  J Biomed Opt       Date:  2013-11       Impact factor: 3.170

Review 4.  Multiscale Functional and Molecular Photoacoustic Tomography.

Authors:  Junjie Yao; Jun Xia; Lihong V Wang
Journal:  Ultrason Imaging       Date:  2015-05-01       Impact factor: 1.578

Review 5.  Photoacoustic imaging as a highly efficient and precise imaging strategy for the evaluation of brain diseases.

Authors:  Ting Qiu; Yintao Lan; Weijian Gao; Mengyu Zhou; Shiqi Liu; Wenyan Huang; Sujuan Zeng; Janak L Pathak; Bin Yang; Jian Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-05

6.  An adaptive filtered back-projection for photoacoustic image reconstruction.

Authors:  He Huang; Gilbert Bustamante; Ralph Peterson; Jing Yong Ye
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

7.  Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array.

Authors:  Guo Li; Lei Li; Liren Zhu; Jun Xia; Lihong V Wang
Journal:  J Biomed Opt       Date:  2015-06       Impact factor: 3.170

8.  Tripling the detection view of high-frequency linear-array-based photoacoustic computed tomography by using two planar acoustic reflectors.

Authors:  Guo Li; Jun Xia; Kun Wang; Konstantin Maslov; Mark A Anastasio; Lihong V Wang
Journal:  Quant Imaging Med Surg       Date:  2015-02

9.  Multiview Hilbert transformation in full-ring transducer array-based photoacoustic computed tomography.

Authors:  Lei Li; Liren Zhu; Yuecheng Shen; Lihong V Wang
Journal:  J Biomed Opt       Date:  2017-07-01       Impact factor: 3.170

Review 10.  Photoacoustic Molecular Imaging: From Multiscale Biomedical Applications Towards Early-Stage Theranostics.

Authors:  Yajing Liu; Liming Nie; Xiaoyuan Chen
Journal:  Trends Biotechnol       Date:  2016-02-26       Impact factor: 19.536

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.