Literature DB >> 23297671

Reduction of number and duration of hypoglycemic events by glucose prediction methods: a proof-of-concept in silico study.

Chiara Zecchin1, Andrea Facchinetti, Giovanni Sparacino, Claudio Cobelli.   

Abstract

BACKGROUND: Hypoglycemia prevention is one of the major challenges in diabetes research. Recently, it has been suggested that continuous glucose monitoring (CGM)-based short-term glucose prediction algorithms could be exploited to generate alerts when hypoglycemia is forecasted, allowing the patient to take appropriate countermeasures to avoid/mitigate the event. However, quantifying the potential benefits of prediction in terms of reduction of number/duration of hypoglycemia requires an in silico assessment that is the object of the present article.
MATERIALS AND METHODS: Data for 50 virtual subjects were generated by using the University of Virginia/Padova type 1 diabetes simulator (54-h monitoring), made more credible by adding realistic measurement noise and perturbations of meals and insulin injections. CGM was assumed to be well calibrated. Occurrence and duration of hypoglycemic events were compared in three scenarios: (1) hypoglycemia was not recognized and not dealt with; (2) 15 g of carbohydrates was ingested when CGM crossed the hypoglycemia threshold; or (3) 15 g of carbohydrates was ingested when the 30-min ahead-of-time CGM prediction crossed the hypoglycemia threshold. The effectiveness of alerts was investigated also in the case of delayed/absent ingestion of carbohydrates.
RESULTS: In Scenario 1, each virtual subject spent 17.7% of the time in the hypoglycemic range, with a median of four events of 120 min in the 54-h period monitored. In Scenario 2, the time spent in hypoglycemia was reduced to 4.7% (four events of 40 min). In Scenario 3, the time spent in hypoglycemia was further reduced to 1.2% (one event of 15 min). Absent/delayed patient's responses to alerts slightly increase these percentages, but improvements remain significant.
CONCLUSIONS: This in silico proof-of-concept study demonstrates that using predicted rather than measured CGM allows a significant reduction of the number of hypoglycemic events and the time spent in hypoglycemic range both by 75%, stimulating further research and clinical investigation on the generation of preventive hypoglycemic alerts exploiting glucose prediction methods.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23297671     DOI: 10.1089/dia.2012.0208

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  14 in total

1.  Physical activity measured by physical activity monitoring system correlates with glucose trends reconstructed from continuous glucose monitoring.

Authors:  Chiara Zecchin; Andrea Facchinetti; Giovanni Sparacino; Chiara Dalla Man; Chinmay Manohar; James A Levine; Ananda Basu; Yogish C Kudva; Claudio Cobelli
Journal:  Diabetes Technol Ther       Date:  2013-08-14       Impact factor: 6.118

2.  Signal processing algorithms implementing the "smart sensor" concept to improve continuous glucose monitoring in diabetes.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

Review 3.  Hypo- and Hyperglycemic Alarms: Devices and Algorithms.

Authors:  Daniel Howsmon; B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2015-04-30

4.  Exploring the Frequency Domain of Continuous Glucose Monitoring Signals to Improve Characterization of Glucose Variability and of Diabetic Profiles.

Authors:  Giuseppe Fico; Liss Hernández; Jorge Cancela; Miguel María Isabel; Andrea Facchinetti; Chiara Fabris; Rafael Gabriel; Claudio Cobelli; María Teresa Arredondo Waldmeyer
Journal:  J Diabetes Sci Technol       Date:  2017-01-09

5.  Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices.

Authors:  Andrea Facchinetti; Simone Del Favero; Giovanni Sparacino; Claudio Cobelli
Journal:  Med Biol Eng Comput       Date:  2014-11-23       Impact factor: 2.602

6.  Evaluation of short-term predictors of glucose concentration in type 1 diabetes combining feature ranking with regression models.

Authors:  Eleni I Georga; Vasilios C Protopappas; Demosthenes Polyzos; Dimitrios I Fotiadis
Journal:  Med Biol Eng Comput       Date:  2015-03-15       Impact factor: 2.602

7.  Using LSTMs to learn physiological models of blood glucose behavior.

Authors:  Sadegh Mirshekarian; Razvan Bunescu; Cindy Marling; Frank Schwartz
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2017-07

Review 8.  Future Perspectives in Glucose Monitoring Sensors.

Authors:  Giulio Frontino; Franco Meschi; Riccardo Bonfanti; Andrea Rigamonti; Roseila Battaglino; Valeria Favalli; Clara Bonura; Giusy Ferro; Giuseppe Chiumello
Journal:  Eur Endocrinol       Date:  2013-03-15

9.  How Much Is Short-Term Glucose Prediction in Type 1 Diabetes Improved by Adding Insulin Delivery and Meal Content Information to CGM Data? A Proof-of-Concept Study.

Authors:  Chiara Zecchin; Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

10.  Non-invasive continuous glucose monitoring with multi-sensor systems: a Monte Carlo-based methodology for assessing calibration robustness.

Authors:  Mattia Zanon; Giovanni Sparacino; Andrea Facchinetti; Mark S Talary; Martin Mueller; Andreas Caduff; Claudio Cobelli
Journal:  Sensors (Basel)       Date:  2013-06-03       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.