Literature DB >> 23294155

Breast microcalcification: diagnostic value of calcified and non-calcified cores on specimen radiographs.

Hatice Gümüş1, Pippa Mills, David Fish, Metehan Gümüş, Haresh Devalia, Sue E Jones, Ali R Sever.   

Abstract

To determine if the specimen without calcification, as depicted on specimen radiography, made any contribution to the final histopathological diagnosis in comparison to the specimen with calcification. The records of 1312 stereotactic vacuum-assisted biopsies for breast microcalcifications between February 2000 and December 2010 were reviewed retrospectively. Following specimen x-ray the biopsy tissues with and without microcalcifications were sent in two separate pots (pot 1 and pot 2 respectively). The number of cores in each pot and the number of calcium specks within the cores were recorded. In 1135 of the 1312 (86%) cases the histopathological findings were similar for pot 1 and pot 2. In 165 cases (13%) the diagnosis was made solely on pot 1 while cores in pot 2 did not reveal any additional pathology. In 12 biopsies (1%) the significant pathology was only present in the specimen without any calcification. For "microcalcification only" breast lesions the specimen containing calcium will yield a correct diagnosis in 99% of cases. Cores containing no calcification rarely contribute to the diagnosis on their own, but in 87% of cases an accurate diagnosis would still have been made even if the targeted calcification had been missed.
© 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23294155     DOI: 10.1111/tbj.12069

Source DB:  PubMed          Journal:  Breast J        ISSN: 1075-122X            Impact factor:   2.431


  4 in total

1.  Vacuum-assisted stereotactic breast biopsy in the diagnosis and management of suspicious microcalcifications.

Authors:  Gül Esen; Burçin Tutar; Cihan Uras; Zerrin Calay; Ümit İnce; Onur Tutar
Journal:  Diagn Interv Radiol       Date:  2016 Jul-Aug       Impact factor: 2.630

2.  Non-stereotactic method involving combination of ultrasound-guided wire localization and vacuum-assisted breast biopsy for microcalcification.

Authors:  Jeeyeon Lee; Ho Yong Park; Jin Hyang Jung; Wan Wook Kim; Seung Ook Hwang; Taek Ju Kwon; Jin Ho Chung; Youngtae Bae
Journal:  Gland Surg       Date:  2016-06

3.  Impact of Non-Calcified Specimen Pathology on the Underestimation of Malignancy for the Incomplete Retrieval of Suspicious Calcifications Diagnosed as Flat Epithelial Atypia or Atypical Ductal Hyperplasia by Stereotactic Vacuum-Assisted Breast Biopsy.

Authors:  Chi Chang Yu; Yun Chung Cheung; Shir Hwa Ueng; Shin Cheh Chen
Journal:  Korean J Radiol       Date:  2020-07-22       Impact factor: 3.500

4.  Visualization positioning-guided biopsy of suspicious breast microcalcifications: a retrospective cohort study.

Authors:  Liulu Zhang; Minyi Cheng; Yuanqi Chen; Xiaosheng Zhuang; Ciqiu Yang; Fei Ji; Hongfei Gao; Mei Yang; Teng Zhu; Jieqing Li; Kun Wang
Journal:  Ann Transl Med       Date:  2021-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.