PURPOSE: To evaluate the reproducibility of spectroscopic measurements from the anterior cingulate (AC) and the dorsolateral prefrontal cortex (DLPFC) regions at 7T using a 32-channel head coil. MATERIALS AND METHODS: Spectra were acquired in four healthy subjects each scanned twice using a stimulated echo acquisition mode (STEAM) sequence, and a MEGA-PRESS-IVS sequence for gamma-aminobutyric acid (GABA) editing. STEAM spectra were quantified using LCModel, whereas MEGA-PRESS-IVS data were analyzed using peak integrals determined using in-house software. Mean coefficient of variation (CV) and mean absolute difference between visits were calculated. RESULTS: For the AC STEAM dataset, the mean CV between visits was 6.2% for prominent metabolites such as N-acetylaspartate (NAA), total creatine (tCr), and total choline (tCho) and 6.3% for low signal-to-noise ratio (SNR) metabolites such as glutamate (Glu), glutamine (Gln), and GABA. The mean CV between visits for the DLPFC STEAM dataset was 8.5% for prominent metabolites and 21% for lower SNR metabolites. In the AC, the reproducibility measures for GABA were superior for STEAM compared to MEGA-PRESS-IVS (mean CV of 3.5% vs. 13.6%), but the opposite pattern was observed in the DLPFC region (mean CV of 16.2% vs. 13.4%). CONCLUSION: 7T MR spectroscopy of the AC and DLPFC using both short TE STEAM and MEGA-PRESS-IVS sequences provide excellent reproducibility of 12 metabolites, including GABA.
PURPOSE: To evaluate the reproducibility of spectroscopic measurements from the anterior cingulate (AC) and the dorsolateral prefrontal cortex (DLPFC) regions at 7T using a 32-channel head coil. MATERIALS AND METHODS: Spectra were acquired in four healthy subjects each scanned twice using a stimulated echo acquisition mode (STEAM) sequence, and a MEGA-PRESS-IVS sequence for gamma-aminobutyric acid (GABA) editing. STEAM spectra were quantified using LCModel, whereas MEGA-PRESS-IVS data were analyzed using peak integrals determined using in-house software. Mean coefficient of variation (CV) and mean absolute difference between visits were calculated. RESULTS: For the AC STEAM dataset, the mean CV between visits was 6.2% for prominent metabolites such as N-acetylaspartate (NAA), total creatine (tCr), and total choline (tCho) and 6.3% for low signal-to-noise ratio (SNR) metabolites such as glutamate (Glu), glutamine (Gln), and GABA. The mean CV between visits for the DLPFC STEAM dataset was 8.5% for prominent metabolites and 21% for lower SNR metabolites. In the AC, the reproducibility measures for GABA were superior for STEAM compared to MEGA-PRESS-IVS (mean CV of 3.5% vs. 13.6%), but the opposite pattern was observed in the DLPFC region (mean CV of 16.2% vs. 13.4%). CONCLUSION: 7T MR spectroscopy of the AC and DLPFC using both short TE STEAM and MEGA-PRESS-IVS sequences provide excellent reproducibility of 12 metabolites, including GABA.
Authors: Dinesh Kumar Deelchand; Pierre-François Van de Moortele; Gregor Adriany; Isabelle Iltis; Peter Andersen; John P Strupp; J Thomas Vaughan; Kâmil Uğurbil; Pierre-Gilles Henry Journal: J Magn Reson Date: 2010-06-10 Impact factor: 2.229
Authors: Lawrence S Kegeles; Xiangling Mao; Arielle D Stanford; Ragy Girgis; Najate Ojeil; Xiaoyan Xu; Roberto Gil; Mark Slifstein; Anissa Abi-Dargham; Sarah H Lisanby; Dikoma C Shungu Journal: Arch Gen Psychiatry Date: 2012-01-02
Authors: Matthew Geramita; Jan Willem van der Veen; Alan S Barnett; Antonina A Savostyanova; Jun Shen; Daniel R Weinberger; Stefano Marenco Journal: NMR Biomed Date: 2011-02-03 Impact factor: 4.044
Authors: Changho Choi; Ivan E Dimitrov; Deborah Douglas; Aditya Patel; Lana G Kaiser; Carlos A Amezcua; Elizabeth A Maher Journal: NMR Biomed Date: 2010-11 Impact factor: 4.044
Authors: Zaiyang Long; Jonathan P Dyke; Ruoyun Ma; Chaorui C Huang; Elan D Louis; Ulrike Dydak Journal: NMR Biomed Date: 2015-08-28 Impact factor: 4.044
Authors: Hetty Prinsen; Robin A de Graaf; Graeme F Mason; Daniel Pelletier; Christoph Juchem Journal: J Magn Reson Imaging Date: 2016-06-28 Impact factor: 4.813
Authors: Muhammad G Saleh; Jamie Near; Alqadafi Alhamud; Frances Robertson; André J W van der Kouwe; Ernesta M Meintjes Journal: MAGMA Date: 2016-07-08 Impact factor: 2.310
Authors: Yue Zhang; Edward Taub; Nouha Salibi; Gitendra Uswatte; Andrew A Maudsley; Sulaiman Sheriff; Brent Womble; Victor W Mark; David C Knight Journal: NMR Biomed Date: 2018-02-13 Impact factor: 4.044
Authors: S Andrea Wijtenburg; Laura M Rowland; Georg Oeltzschner; Peter B Barker; Clifford I Workman; Gwenn S Smith Journal: NMR Biomed Date: 2018-11-29 Impact factor: 4.044