| Literature DB >> 23292408 |
Roman Doleček1, Pavel Psota, Vít Lédl, Tomáš Vít, Jan Václavík, Václav Kopecký.
Abstract
This paper presents a digital holographic method for measurement of periodic asymmetric temperature fields. The method is based on a modified Twyman-Green setup having double sensitivity. For measurement only one precisely synchronized and triggered digital camera is used. The periodicity and self-similarity of each cycle of the measured phenomenon combined with the precisely synchronized camera capture allow one to obtain data later used for three-dimensional (3D) measurement. The reconstruction of 3D temperature field is based on tomographic approach.Year: 2013 PMID: 23292408 DOI: 10.1364/AO.52.00A319
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980