| Literature DB >> 23285206 |
Roberto López-Píriz1, Eva Solá-Linares, Juan J Granizo, Idohia Díaz-Güemes, Silvia Enciso, José F Bartolomé, Belén Cabal, Leticia Esteban-Tejeda, Ramón Torrecillas, José S Moya.
Abstract
The objective of the present study is to evaluate bone loss at implant abutments coated with a soda-lime glass containing silver nanoparticles subjected to experimental peri-implantitis. Five beagle dogs were used in the experiments, 3 implants were installed in each quadrant of the mandibles. Glass/n-Ag coted abutments were connected to implant platform. Cotton floss ligatures were placed in a submarginal position around the abutment necks and the animals were subject to a diet which allowed plaque accumulation, and after 15 weeks the dogs were sacrificed. Radiographs of all implant sites were obtained at the beginning and at the end of the experimentally induced peri-implantitis. The radiographic examination indicated that significant amounts of additional bone loss occurred in implants without biocide coating, considering both absolute and relative values of bone loss. Percentages of additional bone loss observed in implants dressed with a biocide coated abutment were about 3 times lower (p<0.006 distal aspect; and p<0.031 at mesial aspect) than the control ones. Within the limits of the present study it seems promising the use of soda-lime glass/nAg coatings on abutments to prevent peri-implant diseases.Entities:
Mesh:
Substances:
Year: 2012 PMID: 23285206 PMCID: PMC3528675 DOI: 10.1371/journal.pone.0052861
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Outline of the study
(PC – Plaque control; PF – Plaque formation).
Mean values for all variables for mesial and distal aspect of each implant.
| Implant | N | Mean | SD | Mann-Whitney | |
| Distal Aspect Star Point | 1 | 19 | 1.0374 | 0.38824 | 0.062 |
| 0 | 10 | 0.7810 | 0.34301 | ||
| Mesial Aspect Star Point | 1 | 19 | 1.08668 | 0.41696 | 0.085 |
| 0 | 10 | 0.8150 | 0.37456 | ||
| Change Variable Distal Aspect | 1 | 19 | −0.90158 | 0.509327 | <0.001 |
| 0 | 10 | −1.92400 | 0.777435 | ||
| Change Variable Mesial Aspect | 1 | 19 | −1.13000 | 0.563462 | 0.045 |
| 0 | 10 | −1.82300 | 0.894738 | ||
| Reduced Variable Distal Aspect | 1 | 19 | −1.32531 | 1.558999 | 0.006 |
| 0 | 10 | −3.47447 | 3.077830 | ||
| Reduced Variable Mesial Aspect | 1 | 19 | −2.04426 | 3.723847 | 0.031 |
| 0 | 10 | −3.73327 | 4.545198 |
Implant: 1 = case implant; 0 = control implant.
Similar variances are assumed.
Change Variable (Distal or Mesial) = Initial mean value – Final mean value.
Reduced Variable (Distal or Mesial) = (Initial mean value – Final mean value)/Initial mean value.
Figure 2Scanning electron micrographs at different magnifications of cross section of the abutment.
Figure 3Images for the control implant
(1) and for the coated implants (2 and 3). (a) week 25 and (b) week 36.
Figure 4Digital micrographs for the control implants.
(1) and coated implants (2 and 3). (a) week 24 and (b) week 36. A picture showing the intermediate 2 mm height machine titanium surface abutment has been inserted. The distance between the abutment-fixture junction (A/F) and the marginal position of bone-to-implant contact (B) is shown.
Figure 5Transverse section of implants at the end of experiment.
(a) Implant without coating and (b) implant coated by glass/nAg.
Figure 6Scanning electron micrographs of the surface for
(a) titanium implant and (b) coated/nAg titanium implant.